Skip to content

ECB violations

329-335 East 41 Street, Manhattan • Block 01334 • Lot 0013

15 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Dec 7, 2020 35542248H RESOLVE CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE:ROOF LEVEL:CRACK ON PARAPET AT EXPOSURE 2,WEST E... $1,250 $0 Feb 18, 2021
Sep 21, 2012 34990125K RESOLVE CLASS - 1 NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AUTHORIZED PERSON AT SITE - NOTED: NO DAILY INSPECTI... $2,400 $0 Feb 7, 2013
Sep 21, 2012 34952537J RESOLVE CLASS - 1 FAILURE TO PROVIDE/USE LIFELINE WHILE WORKING ON SCAFFOLD. NOTED: AT TIME OF INSPECTION OBSERVED A MR. MARCELO TENETE... $1,600 $0 Feb 7, 2013
Sep 21, 2012 34952538L RESOLVE CLASS - 2 FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INST OFF OUTRIGGER BEAMS IN CONNECTION W/SUSPENDED SCAFFOLDS. NOTED:... $400 $0 Feb 7, 2013
Sep 21, 2012 34952534Y RESOLVE CLASS - 1 WORK W/O A PERMIT. NOTED: EXPIRED FACADE PERMIT ON 9.15.12 AT TIME OF INSPECTION, WORKERS ON SITE WERE WORKING ON PAR... $800 $0 Apr 25, 2013
Sep 21, 2012 34952535X RESOLVE CLASS - 2 EXPIRED PERMIT. NOTED: EXPIRED CD-5 FOR OUTRIGGER BEAMS ON 9.7.11, OUTRIGGERS BEAMS WERE IN USE AT PARAPET AT TIME OF... $400 $0 Feb 7, 2013
Sep 21, 2012 34990126M RESOLVE CLASS - 1 RIGGER FAILED TO DESIGNATE A FOREMAN. NOTED: AT TIME OF INSPECTION, NORIGGING FOREMAN ON SITE, WHILE SUSPENDED SCAFFO... $1,600 $0 Feb 7, 2013
Sep 21, 2012 34952536H RESOLVE CLASS - 1 FAILURE TO FILE EVIDENCE OF LIABILITY INSURANCE. NOTED: EXPIRED LIABILITY INSURANCE ON 9.15.12 JOB SITE WAS ACTIVE AT... $0 $0 Feb 7, 2013
Jul 15, 2002 38122424X RESOLVE Non-Hazardous 26I11/50B11/50Y14. 26I11 REPAIRED DEMAYED UPPER LXXXX XX. 50B11 REPAIRED HOIST MOTOR COMMUTATOR. 50-Y-14 REPAIRED AND... $0 $0 Aug 29, 2002
Jun 25, 2002 38123746N RESOLVE Non-Hazardous 73R2. OPERATING AN EWUIPMENT WITH OUT PERMIT CAUSE USE CALL THE DEPT OF BUILDING FOR APPOINTMENT TO TEST 5071-02 ART ... $0 $0 Aug 15, 2002
Apr 23, 2002 38123161H RESOLVE Non-Hazardous 17Q07. PROVIDE VISION GUARDS ON SHAFT DOORS. $0 $0 Jun 27, 2002
Dec 29, 1997 38068647Z RESOLVE Non-Hazardous 29I,46U,47B,50Y, 29-CHANGE BROKEN SPRING ON CWT. 46-RESHACKLE TOP OF CAR CABLES 47-SHORTEN GOVERNOR CABLE 50-SEAL MAC... $0 $0 Feb 19, 1998
Dec 29, 1997 38068646R RESOLVE Non-Hazardous 46U,50Y,07X,15M, 46-RESHACKLE TOP OF CAR HOIST ROPES 50-SEAL MACHINE 07-REPAIR SAFETY EDGE 15-COVER ELECTRICAL BOX IN... $0 $0 Feb 19, 1998
Jun 15, 1991 38014002H RESOLVE Non-Hazardous 28H,02X,35P $0 $0 Sep 26, 1991
Jan 19, 1989 34020632H RESOLVE Non-Hazardous WORK WITHOUT A PERMIT WORK NOTED INTERIOR PARTITIONS WORK MADE OF WOOD AND METAL STUDS AT 2 & 3 STYS POLUMBING WORK I... $0 $0 Mar 2, 1989