ECB violations
East 44 Street, Manhattan • Block 01337 • Lot 0006
49 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 1, 2025 | 39539730Y | RESOLVE | CLASS - 1 | UPON INSPECTING ACTIVE CONSTRUCTION SITE OBSERVED SIDEWALK SHED INSTALLED AT EXP. 1 CONTRARY TO DRAWINGS. OBSERVED MI... | $625 | $625 | Aug 7, 2025 |
| May 1, 2025 | 39539722Y | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION SITE. UPON REVIEW MANUFACTURE SPECS OF ALTREX NOTICE PLATFORM DOES... | $1,250 | $0 | Jul 10, 2025 |
| May 1, 2025 | 39539729R | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES. OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE 1. UPON R... | $1,250 | $0 | Jul 10, 2025 |
| May 1, 2025 | 39539728P | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES. UPON REVIEWING SIDEWALK SHED DRAWINGS OBSERVED STORAGE... | $1,250 | $0 | Jul 10, 2025 |
| Feb 4, 2025 | 35667839Z | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED SWS ALTERED AT CORNER OF EXP. 1(FRONT OF BUILDING) AND EXP. 2(LEFT SIDE OF BUILDING). ... | $2,500 | $0 | Apr 17, 2025 |
| Feb 4, 2025 | 39137400J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED SWS ALTERED AT CORNER OF EXP.1(FRONT OF BUILDING) AND EXP. 2 (LEFT SIDE OF BUILDING). ... | $0 | $0 | Apr 10, 2025 |
| Nov 26, 2024 | 39534729Y | RESOLVE | CLASS - 2 | UPON REQUEST GC WAS UNABLE TO PROVIDE MANUFACTURER SPECIFICATIONS FOR OBSERVED SUPPORTED SCAFFOLD AT EXPOSURE #1 OF T... | $1,280 | $0 | Mar 6, 2025 |
| Nov 26, 2024 | 39534727K | RESOLVE | CLASS - 2 | OBSERVED INADEQUATE HOUSEKEEPING AT THE ROOF LEVEL; NOTING THE ACCUMULATION OF DEBRIS AND BUILDING MATERIAL WHICH PRE... | $0 | $0 | Mar 6, 2025 |
| Nov 26, 2024 | 39534726Z | RESOLVE | CLASS - 2 | EXPOSURE #1 SIDEWALK SHED INSTALLED CONTRARY TO APPROVED SHED DRAWINGS (EQ-001.00, EQ-004.00 AND SSP-102.00). SHED FA... | $1,280 | $0 | Mar 6, 2025 |
| Jan 16, 2024 | 37026228M | ACTIVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FA... | $6,250 | $0 | May 19, 2025 |
| Jun 29, 2018 | 35324336M | RESOLVE | CLASS - 1 | BUILT CONTRARY TO PLAN. ALL EQUIPMENT MUST BE INSTALLED AS PER CD/5 APPROVED PLAN. NOTE: AT TIME OF INSPECTION I OBSE... | $2,500 | $0 | Aug 16, 2018 |
| Jun 29, 2018 | 35324335K | RESOLVE | CLASS - 2 | SEC. 3314.3.2 DESIGN/DRAWINGS FOR C-HOOKS. DRAWINGS ARE TO BE ON SITE AT TIME OF INSPECTION. NOTE: AT TIME OF INSPECT... | $625 | $0 | Aug 16, 2018 |
| Jun 29, 2018 | 35324334Z | RESOLVE | CLASS - 1 | SEC. 104-20 DESIGNATED FOREMAN/RIGGER-RIGGER OR DESIGNATED FOREMAN MUST BE ON SITE WHILE USE OF SUSPENDED SCAFFOLD IN... | $2,500 | $0 | Aug 16, 2018 |
| Jun 29, 2018 | 35324333R | RESOLVE | CLASS - 1 | SITE SAFETY MONITORING PROGRAM. NOTE: AT TIME OF INSPECTION I OBSERVEDACTIVE FACADE JOB IN PROGRESS W/NO SITE SAFETY ... | $10,000 | $0 | Aug 16, 2018 |
| Jun 29, 2018 | 35324337Y | RESOLVE | CLASS - 1 | SEC. 3314.10.1 SUSPENDED ELEMENTS TO BE KEPT VERTICAL. NOTE: AT TIME OF INSPECTION I OBSERVED SUSPENDED SCAFFOLD INST... | $2,500 | $0 | Aug 16, 2018 |
| Mar 20, 2018 | 35318603R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES SOUTH ELEVATION EXP1: CRACK AND SPALLING OF BRICKS AND... | $2,500 | $0 | May 10, 2018 |
| Mar 20, 2018 | 35318605K | RESOLVE | CLASS - 1 | OWNER FAILED TO REPAIR BUILDING EXTERIOR FACADE AND APPURTENANCES AS NOTED: QEWI STTES THAT CONDITIONS FROM CYCLE 7 S... | $2,500 | $0 | May 10, 2018 |
| Mar 20, 2018 | 35318604Z | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED MEASURES TO PROTECT PUBLIC FROM UNSAFE FACADEAS NOTED: ON 2/20/18 307 EST 44 ST FILED A FISP... | $0 | $0 | May 10, 2018 |
| Oct 5, 2015 | 38238465R | RESOLVE | CLASS - 2 | 06H11,18B06,21B07,58H10. 06H11-CAR DOOR GATE ROLLER WORN REPLACE; 18B06-1ST FLR HATCH DOOR SPRING CLOSER LOOSE BRACKE... | $0 | $0 | Nov 19, 2015 |
| Feb 7, 2013 | 38225368M | RESOLVE | CLASS - 2 | 05M07,100M07,71M07. 05M07-PROVIDE DOOR ZONE RESTRICTORS;100M07-PROVIDE SAFETY PLANK SWITCH; 71M07-PROVIDE PIT LIGHT. | $0 | $0 | Mar 28, 2013 |
| Jan 16, 2012 | 38220062R | RESOLVE | CLASS - 2 | 97X10;RESTORE TO SERVICE FOR PROPER D.O.B INSPECTIONS. | $250 | $0 | Mar 1, 2012 |
| Dec 7, 2008 | 36006516M | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE SIXTH ROUND TECHNICAL REPORT IN COMPLAINCE WITH CODE PROVISIONS: PERIODIC INSPECTION ... | $0 | $0 | Nov 12, 2009 |
| Apr 14, 2008 | 34636179Y | RESOLVE | Hazardous | 27-1046 1) NO RECORD OF DAILY INSPECTION OF THE SCAFFOLDS PERFORMED BY AN AUTHORIZED PERSON AT THE SITE. 2) STIRRUPS ... | $2,000 | $0 | Aug 14, 2008 |
| Apr 14, 2008 | 34636178M | RESOLVE | Hazardous | 1) LICENSED RIGGER FAILED TO NAME A DESIGNATED FOREMAN. "NO FOREMAN I.D." 2) LICENSED RIGGER FAILED TO ENSURED THAT T... | $250 | $0 | Aug 14, 2008 |
| Feb 17, 2006 | 38157288K | RESOLVE | Non-Hazardous | 83O02/38M07/58M07/33M07/70J01/49D07/43D06/33#09. 83- CLEAN ENTIRE DEVICE, OVERHEAD SHEAVES, ALL STEEL, RAILS, TOP OF ... | $0 | $0 | Apr 6, 2006 |
| Feb 17, 2006 | 38157285P | RESOLVE | Hazardous | 83O02/03#01/33M07/49D07/43D06/64Q07. 83- CLEAN ENTIRE DEVICE, OVERHEAD SHEAVES, ALL STEEL, RAILS, TOP OF CAR, UNDERSI... | $0 | $0 | Apr 6, 2006 |
| Feb 17, 2006 | 38157281H | RESOLVE | Non-Hazardous | 83O02/58M07/33M07/49D07/43D06/64Q07. 83- CLEAN ENTIRE DEVICE, OVERHEADSHEAVES & ALL STEEL, RAILS, TOP OF CAR, UNDERSI... | $0 | $0 | Apr 6, 2006 |
| Nov 8, 2004 | 38137343X | RESOLVE | Non-Hazardous | 12M07/19M07/80D06 12-M-07 PROVIDE LIGHT GUARD IN CAR AND UNDER 19-M-07PROVIDE COVER FOR LOBBY LEVEL INTER LOCK 80-D-0... | $0 | $0 | Dec 23, 2004 |
| Jun 24, 2003 | 38139734M | RESOLVE | Non-Hazardous | 84M7 40M7 84-M-7-PROVIDE TOW GUARD UNDER CAR 40-M-7-PROVIDE SIGN FOR MOTOR ROOM DOOR. | $350 | $0 | Dec 18, 2003 |
| Apr 4, 2003 | 34381847Z | RESOLVE | Non-Hazardous | ALTERED BUILDING OCCUPIED W/O A VALID CERTIFICATE OF OCCUPANCY NOTED :C OF O # 92491 STATES ON 1ST FL AS BEING A DRUG... | $0 | $0 | May 22, 2003 |
| Nov 22, 2002 | 38135182P | RESOLVE | Non-Hazardous | 18I12/ 19Q3/ 23M7/ 18-I-12 REPLACE VISION GLASS ON 1ST FLOOR 19-Q-03 - INTERLOCK COVER MISSING ON BASEMENT LOCK 27-M-... | $180 | $0 | Mar 13, 2003 |
| Nov 28, 2000 | 32020753L | RESOLVE | Hazardous | 49-32A-26 FUMES FROM BOILER CAUSING HAZARDOUS CONDITIONS. EXPOSED ON CONTROLS END JUNCTION BOXES. TEST LEVER MISSING ... | $800 | $0 | Mar 1, 2001 |
| Oct 31, 2000 | 38108799L | RESOLVE | Non-Hazardous | 37U16,50U16,54U16,50Y14,74B07. 37&50&54U16-PROPERTY TAG DEVICE WITH CITY ID NO.,50U14-SEAL OIL LEAK,74B07-PROVIDE MAI... | $350 | -$350 | Dec 21, 2000 |
| Jul 26, 2000 | 34236925Y | RESOLVE | Non-Hazardous | OCCUAPNCY CONTRARYT TO THAT ALLOWED BY THE C OF O APTM REMEDY; DICONTINUE ILELGAL USE OR AMEND C OF O. | $800 | $0 | Nov 2, 2000 |
| Nov 9, 1999 | 34228324Z | RESOLVE | Non-Hazardous | ILLEGAL USE IN A COMMERCIAL DISTRICT NOTED: BSMT 1ST FLOOR OF FRONT SECTION OF BUILDING NOW OCCUPIED AS ADULT EDUCATI... | $0 | $0 | Mar 2, 2000 |
| Nov 9, 1999 | 34228323R | RESOLVE | Non-Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C/O #92491 ISSUED JULY 88 NOTED : BSMT LEVEL /1ST FLOOR CONVERTED FROM RESI... | $0 | $0 | Mar 2, 2000 |
| Dec 12, 1997 | 38067439J | RESOLVE | Non-Hazardous | 50D47B75U54U74D74B 50-EXPOSE WIRE ON MACHINE 47-GOVERNOR SHORTING 75-5 YEAR TEST TAG 54 NO CITY TAG 74-WIRES EXPOSE O... | $180 | $0 | Feb 5, 1998 |
| Dec 12, 1997 | 38067441Z | RESOLVE | Non-Hazardous | 50D44D54U 50-WIRE EXPOSE ON MACHINE 44-WIRES EXPOSE ON GENERATOR 54-NO CITY TAG. | $180 | $0 | Feb 5, 1998 |
| Dec 12, 1997 | 38067440R | RESOLVE | Non-Hazardous | 75U50Y50D37B74D54U 25-5 YEAR TEST TAG 50-OIL LEAK ON MAIN MACHINE 50-WIRES EXPOSE ON MACHINE 37 PROVIDE GUARD FOR OVE... | $180 | $0 | Feb 5, 1998 |
| May 13, 1997 | 38059782R | RESOLVE | Non-Hazardous | 22D30I35O34I37#50Y57O35I (30) PATCH ALL HOLE IN HOISTWAY (37) WIRE ON CONTROLLER WORN | $200 | $0 | Sep 25, 1997 |
| May 12, 1997 | 38059779X | RESOLVE | Non-Hazardous | 18M22Q32M34I34H35O46H47H57O61H64E75# (18) COVER MISSING ON INTERLOCK ON BMENT LFOOR (32) COVER MISSING UNDER CAR CW C... | $200 | $0 | Sep 25, 1997 |
| May 12, 1997 | 38059777M | RESOLVE | Non-Hazardous | 28H30O32M35O49#46#47H50Y50#57O75932)COVER MISSING ON DUCT WORK TOP OF CAR (44) GENERATOR BURSHS LOW REPLACE TEHM (50)... | $200 | $0 | Sep 25, 1997 |
| May 12, 1997 | 38059778Y | RESOLVE | Non-Hazardous | 13M28H30O32M35O35Q50Y75# 32 COVER MISSING ON DUCT WORK TOP OF CAR 35 METAL WALL BUY THE PIT & MOTOR RM IS LOOSE PROPE... | $200 | $0 | Sep 25, 1997 |
| Nov 13, 1995 | 38052223Z | RESOLVE | Non-Hazardous | 75U, 60L, 18Q ##, 26Q, 27Q, 36I, 36W, 57O, 50O, 52O. ##-SADDLE DAMAGED B-1 FLOORS REPAIR. | $100 | $0 | Jan 4, 1996 |
| Jan 5, 1993 | 38028143Z | RESOLVE | Non-Hazardous | 19M | $250 | $0 | Mar 5, 1993 |
| Jan 5, 1993 | 38028144K | RESOLVE | Non-Hazardous | 11Q,14M,19M,22D,35Z, (35) ABOVE GENERATOR | $100 | $0 | Feb 19, 1993 |
| Sep 3, 1991 | 38015711P | RESOLVE | Non-Hazardous | 18L;22M;08M;37G;19M;73#;50H;39H;46H; 18.LOBBY SIDE. 08.CORNER FOR SAFESAFETY WIDE. 73.PERFORM 5 YR TEST PROPERLY TAG ... | $0 | $0 | Jan 10, 1992 |
| Sep 3, 1991 | 38015712R | RESOLVE | Non-Hazardous | 19M | $150 | $0 | Nov 21, 1991 |
| Jun 8, 1988 | 34007306X | RESOLVE | Non-Hazardous | ATLERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY ALT1710 REMEDY: OBTAIN A VALED CERTIFICATE OF OCCU... | $0 | $0 | Jul 28, 1988 |