ECB violations
2 East 60 Street, Manhattan • Block 01374 • Lot 0069
36 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 3, 2025 | 39546626J | RESOLVE | CLASS - 2 | DURING MY INSPECTION OF AN ACTIVE 18-STORY ALT, I REQUESTED THE JORGE E. SINCHI TO PROVIDE THE SUPPORTED SCAFFOLD DAI... | $1,250 | $0 | Jan 8, 2026 |
| Nov 3, 2025 | 39546621K | RESOLVE | CLASS - 2 | AT THE TIME OF THE INSPECTION ON A ACTIVE JOB SITE,I OBSERVED PIPE SCAFFOLD AT EXP#3,4 WAS NOT BUILD AS PER CODE/APPR... | $0 | $0 | Jan 8, 2026 |
| Nov 3, 2025 | 39546619L | RESOLVE | CLASS - 2 | 1RCNY-3310-01(E)(1) AT THE TIME OF INSPECTION ON AN ACTIVE JOB SITE, IT WAS OBSERVED THAT THERE WERE WORKERS ON SITE.... | $0 | $0 | Jan 8, 2026 |
| Nov 3, 2025 | 39546628N | RESOLVE | CLASS - 2 | BC3303.7.2 - DURING MY INSPECTION OF AN 18-STORY ALT/ACTIVE JOB SITE, I OBSERVED THAT THE FIRE EXTINGUISHERS WERE INA... | $625 | $0 | Jan 8, 2026 |
| Feb 10, 2025 | 39536784X | RESOLVE | CLASS - 2 | BC 3314.16.4//CORNER ANGLE INSPECTION//-AT THE TIME OF MY INSPECTION OBSERVED 5 CORNER ANGLE SCAFFOLD INSTALLED AT EX... | $2,500 | $0 | Apr 17, 2025 |
| Jan 9, 2018 | 35296065Y | RESOLVE | CLASS - 2 | PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT TO 28-207.2 AND POSTED ON PREMISES.TEMP CONSTRUCTION EQUIPMENT ON ... | $830 | $0 | Mar 1, 2018 |
| Jan 9, 2018 | 35296063K | RESOLVE | CLASS - 2 | PARTIAL SWO ISSUED FOR SUPPORTED SCAFFOLD PURSUANT 28-207.2.AND POSTED ON PREMISES.FAILURE TO PROVIDE APPROVED PLANS ... | $0 | $0 | Mar 1, 2018 |
| Jan 9, 2018 | 35296064M | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED PLANS.AT TIME OF INSPECTION CROSS VRACES FOR THE SIDEWALK SHED ARE NOT INSTALLED FO... | $0 | $0 | Mar 1, 2018 |
| Jul 18, 2017 | 35259782Y | RESOLVE | CLASS - 2 | SEC. 3314.10 SUSPENDED ELEMENTS TO BE KEPT VERTICAL & PANELLEL. NOTE: AT TIME OF INSPECTION I OBSERVED SUSPENDED SCAF... | $400 | $0 | Sep 7, 2017 |
| Jul 18, 2017 | 35259778L | RESOLVE | CLASS - 2 | SEC. 3310.4 SITE CONDITION. CONDITION OF SITE HAS TO BE IN CONFORMANCE W/SSP. NOTE: AT TIME OF INSPECTION I OBSERVED ... | $0 | -$800 | Sep 7, 2017 |
| Jul 18, 2017 | 35259781M | RESOLVE | CLASS - 2 | SEC. 3307.6.4.4 VERTICALS. VARTICAL MEMBERS NEAREST THE CURB CUT OR VEHICULAR ACCESS POINT SHALL BE PROTECTED AGAINST... | $800 | $0 | Sep 7, 2017 |
| Jul 18, 2017 | 35259780K | RESOLVE | CLASS - 2 | BUILT IN ACCORDANCE W/PLANS EQUIPMENT ON SITE IS CONTRARY TO APPROVED PLANS. NOTE: AT TIME OF INSPECTION I OBSERVED S... | $250 | $0 | Sep 7, 2017 |
| Jul 18, 2017 | 35259779N | RESOLVE | CLASS - 2 | SEC. 3314.4.3.2 INSTALLATION INSPECTION. ALL EQUIPMENT IS TO BE INSPECTED ONCE INSTALLATION IS COMPLETE(AS POER DRAWI... | $400 | $0 | Sep 7, 2017 |
| Feb 11, 2017 | 35117041N | RESOLVE | CLASS - 1 | BC3301.2. CD #4705 CN #493/15 HMO #5982. FAILURE TO MAINTAIN CONSTRUCTION EQUIPMENT. AT TIME OF PERFORMING A AUDIT IN... | $1,600 | $0 | Mar 23, 2017 |
| Jan 10, 2017 | 35200285R | RESOLVE | CLASS - 1 | 3314.15.2 STIRRUPS.STIRRUPS ARE TO BE INSTALLED AS PER MANUFACTURING SPECS.NOTE:@TIME OF INSPECTION I OBSERVED SUSPEN... | $1,600 | $0 | Apr 20, 2017 |
| Sep 21, 2015 | 37000118X | RESOLVE | CLASS - 2 | 28-317.3 FAILURE TO REGISTER COOLING TOWER.REM:COMPLY WITH CODE. | $800 | $0 | Feb 11, 2016 |
| Aug 19, 2015 | 35145363Y | RESOLVE | CLASS - 1 | 3301.7 FAILURE TO PROVIDE DESIGN DRAWINGS W/ (VERTICAL) OR ENGINEERS SEAL.FOR TEMPORARY WOOD PLATFORM @ EXP2 & 3 @ 18... | $500 | $0 | Oct 8, 2015 |
| Aug 19, 2015 | 35145364X | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM APPROVED CONSTRUCTION/(SHED) DOCUMENTS;DESIGN DRAWINGS.PARAPET HAS NOT BEEN ERECTED AS SHOWS ON... | $0 | $0 | Oct 8, 2015 |
| Jul 2, 2015 | 35132421K | RESOLVE | CLASS - 1 | BC 3314.6.1 PSWO:ISSUED & POSTED @SERVICE ENTRANCE.(STOP ALL SUPPORTEDSCAFFOLD WORK FROM 15TH FL UP TO ROOF).SUPPORTE... | $1,600 | $0 | Aug 20, 2015 |
| Mar 24, 2015 | 35034984P | RESOLVE | CLASS - 1 | SWO - 032415DKM01. OPERATION OF ARTICULATING BOOM CRANE W/O A CERT OF OPERATION AT TIME OBSERVED EQUIPMENT BEING USED... | $1,000 | $0 | Oct 15, 2015 |
| Mar 9, 2015 | 35122553N | RESOLVE | CLASS - 1 | USE OF SUPPORTED SCAFFOLD W/O A SCAFFOLD USER CERTIFICATE. WORKER STEPHEN ESPOSITO ON PIPE SCAFFOLD USER CERTIFICATE ... | $1,600 | $0 | May 28, 2015 |
| Mar 9, 2015 | 35122554P | RESOLVE | CLASS - 1 | SEC. 28-110.1 OSHA 10 WORKERS: CARLOS NIETO JR (WELDER) OSHA 10 WAS TAKEN OVER 5YRS AGO. STEPHEN ESPOSITO OSHA10 DATE... | $400 | $0 | May 28, 2015 |
| Aug 30, 2013 | 35029920J | RESOLVE | CLASS - 3 | WORK W/O A PERMIT. WORK NOTED: AT TIME OF INSPECTION A DEBRIS CHUTE ISBEING USED W/O A PERMIT. DEBRIS IS BEING REMOVE... | $0 | $0 | Oct 17, 2013 |
| Jul 30, 2010 | 34858037M | RESOLVE | CLASS - 1 | SEC. 3314.15.5 NO MORE THAN 2 WORKERS SHALL BE PERMITTED TO WORK ON 1 SCAFFOLD AT 1 TIME. WRITTEN PERMISSION FROM THE... | $1,600 | $0 | Jul 28, 2011 |
| Jul 16, 2010 | 34858002M | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. MISSING CROSS BRACES ON EXP# 1, ... | $0 | $0 | Sep 9, 2010 |
| Feb 13, 2010 | 34835151Y | RESOLVE | CLASS - 2 | FAILURE TO FILE A C/C FOR VIO #34808360R. REMEDY: FILE C/C. | $4,000 | $0 | May 6, 2010 |
| Sep 15, 2009 | 34808360R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER NOTED AT CELLAR LEVEL AT EXP 1 WEST FACADE OF BLDG AT CELLAR LEVEL ... | $1,000 | $0 | Jun 24, 2010 |
| Dec 19, 2008 | 36006616J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $400 | $0 | Oct 29, 2009 |
| May 27, 2008 | 38185085Z | RESOLVE | Non-Hazardous | 85BB05,63M07,66O02,10H11.85BB-5YR EXPIRED 3/04 PERFORM & FILE TEST.63M-MAIN LINE.PANEL (1,2,3 CAR, HOUSE/PWR) CITY ID... | $180 | $0 | Jul 17, 2008 |
| May 27, 2008 | 38185084R | RESOLVE | Non-Hazardous | 08O02,38P06,84X10,51O02,55Y10,55Y13,59M07,84T07,64Q02,64O02,71Q03,85BB05.08O-SADDLES DIRTY SCRAP & CLEAN.38D-T.O.C. L... | $180 | $0 | Jul 17, 2008 |
| Oct 5, 2006 | 34538327H | RESOLVE | Non-Hazardous | FAILURE TO MAINATIN BLDG NOTED 1ST FLR COMMERCIAL SPACE @ E 60 ST EASTSIDE (PARKING GARAGE) HAVING DEFECTIVE NOT OPER... | $0 | -$180 | Nov 16, 2006 |
| Jan 2, 1998 | 38066466K | RESOLVE | Non-Hazardous | 30O,74O,57O,74M,36T, 74 TOP OF CAR 74 FIRE EXT MISSING | $0 | $0 | Feb 26, 1998 |
| Jan 2, 1998 | 38066465Z | RESOLVE | Non-Hazardous | 36O,36T,37U,50U,54U,50O,37O, | $0 | $0 | Feb 26, 1998 |
| Jan 2, 1998 | 38066464R | RESOLVE | Non-Hazardous | 37U,50U,54U,36T, | $0 | $0 | Feb 26, 1998 |
| Jan 2, 1998 | 38066463P | RESOLVE | Non-Hazardous | 46I,30O,31Q,74O,46 EXSESIVE BREAKS IN CABLE 74 TOP OF CAR | $0 | $0 | Feb 26, 1998 |
| Jun 5, 1991 | 38010269Z | RESOLVE | Non-Hazardous | 46L. | $75 | $0 | Aug 1, 1991 |