ECB violations
2-6 East 61 Street, Manhattan • Block 01375 • Lot 0067
83 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 4, 2023 | 35670325Z | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE & APPURTENANCE.NOTE:AT TIME OF INSPECTION OBSERVED AT EXP #3 WEST ELEVAT... | $2,500 | $0 | Apr 13, 2023 |
| Dec 2, 2022 | 37024027R | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE9A REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTEN... | $6,250 | $0 | Feb 23, 2023 |
| Aug 18, 2022 | 39505218J | ACTIVE | CLASS - 2 | TIME OF INSPECTION OBSERVED FROM SIDEWALK/STREET ERECTED SCAFFOLD/STAIR TOWER AT EXPOSURE 1,2 AND 4. UPON REVIEW ON B... | $1,280 | $0 | Nov 17, 2022 |
| Mar 16, 2022 | 39058170H | RESOLVE | CLASS - 1 | I OBSERVED IN APT ON 18TH FLOOR SPRINKLER HEADS REMOVED AND AS PER DOB RECORDS PLUMBER THAT PERFORMED WORK DOES NOT H... | $0 | $0 | Dec 28, 2023 |
| Mar 15, 2022 | 35645353L | ACTIVE | CLASS - 1 | BC3314.1 UNSAFE SUPPORTED SCF ATOI OF ACTIVE JOBSITE OF 4STYB OBSERVEDWORKERS PERFORMING WORKS ON LEVEL2&USING SUPPOR... | $2,500 | $0 | Jun 16, 2022 |
| Mar 14, 2022 | 39058171J | RESOLVE | CLASS - 1 | I OBSERVED REMOVAL OF 2 SPRINKLER HEADS IN APT ON 18TH FLOOR AND THERE WAS PERMIT ISSUED FOR WORK PERFORMED; HOWEVER ... | $0 | $0 | Dec 28, 2023 |
| Aug 4, 2021 | 35589110N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33NOTED AT TIME OF INSPECTION AT A 41 STORY FACAD... | $1,250 | $1,250 | Jun 2, 2022 |
| Aug 4, 2021 | 35589112R | RESOLVE | CLASS - 1 | 3314.4.4.3.2.1 FAILURE TO PROVIDE PRE AND POST INSTALLATION INSPECTIONLETTER/REPORT.NOTED AT TIME OF INSPECTION AT A ... | $2,500 | $0 | Mar 3, 2022 |
| Aug 4, 2021 | 35589111P | ACTIVE | CLASS - 2 | EXPIRED SCAFFOLD PERMIT.NOTE AT TIME OF INSPECTION AT A 41 STORY FACADE RESTORATION OPEN ACTIVE SITE,OBSERVED SUPPORT... | $625 | $625 | Jun 2, 2022 |
| Aug 4, 2021 | 35589108Y | ACTIVE | CLASS - 1 | FAILURE TO FILE EVIDENCE OF LIABILITY OR PROPERTY DAMAGE INSURANCE-LIABILITY INSURANCE EXPIRED.NOTED AT TIME OF MY IN... | $625 | $625 | Jun 2, 2022 |
| Aug 4, 2021 | 35589109X | ACTIVE | CLASS - 2 | WORK WITHOUT A PERMIT-PERMIT EXPIRED.NOTED AT TIME OF INSPECTION AT A 41 STORY FACADE RESTORATION OPEN ACTIVE SITE OB... | $625 | $625 | Jun 2, 2022 |
| May 26, 2021 | 35557300H | RESOLVE | CLASS - 1 | BC33012-SAFETY MEASURES AND STANDARDS(MISSING GUARRAILS AND HAND RAILSAT THE TIME OF INSPECTION ON AN ACTIVE JOB SITE... | $2,500 | $2,500 | Apr 7, 2022 |
| May 26, 2021 | 35556699Y | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.(MAINTENANCE)AT THE TIME OF MY INSPECTION ON AN ACTIVE JOB SI... | $2,400 | $0 | Feb 24, 2022 |
| Jun 3, 2020 | 37019151H | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A AND 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INI... | $0 | $0 | Jan 28, 2021 |
| Jan 11, 2020 | 35411351X | RESOLVE | CLASS - 2 | BC3301.4&1RCNY 3316-01=FAILURE TO PROVIDE INSPECTION LOGS CD4493 WAS OBSERVED SET UP & HOISTING HVAC MATERIAL EAST 61... | $0 | $0 | Mar 19, 2020 |
| Aug 12, 2019 | 35448941P | ACTIVE | CLASS - 1 | FAILURE TO FILE EVIDENCE OF COMPLIANCE W/WORKERS COMP LAW &/OR DISABILITY(BENEFITS LAW). AT 41 EXISTING BLDG ON AN AC... | $25,000 | $25,000 | Jul 16, 2020 |
| Jun 21, 2019 | 35435330N | RESOLVE | CLASS - 1 | PROHIBITED OUTDOOR ADVERTISING COMPANY SIGN ON SIDEWALK SHED OR CONSTRUCTION FENCE.AT TIME OF INSPECTION,I OBSERVED S... | $0 | $0 | Aug 22, 2019 |
| Jun 21, 2019 | 35435331P | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.STORAGE ON SHE D.NOTED:AT TIME OF INSPECTION,I OBSERVED SWS IN... | $0 | $0 | Aug 22, 2019 |
| Jan 11, 2019 | 35411350Y | RESOLVE | CLASS - 2 | FAILURE DISPLAY DANGER SIGNS CD4492 WAS OBSERVED SET UP ON EAST 61 ST HOISTING HVAC MATERIAL UPON AUDIT NO REQUIRED D... | $1,250 | $0 | Sep 10, 2020 |
| Jul 18, 2018 | 35308234L | RESOLVE | CLASS - 2 | FAILURE TO FILE A FINAL INSPECTION FOR COMPLETED WORK WITHIN 1 YEAR OFPERMIT EXPIRATION. PREMISES UNDER ALT2 #1205273... | $620 | $0 | Sep 6, 2018 |
| Feb 27, 2018 | 35265177R | ACTIVE | CLASS - 1 | FAILURE TO TAKE REQUIRED MEASURES TO PROTECT PUBLIC FROM UNSAFE FACADEAS NOTED ON 2/22/18 BUILDING FILED A FISP3 UNSA... | $2,400 | $0 | Jun 28, 2018 |
| Jun 23, 2017 | 35264101X | ACTIVE | CLASS - 2 | REMOVAL OF SAFETY MEASURES/SIDEWALK SHEDS WITHOUT DEPARTMENTS APPROVAL,NOTE:AT THE TIME OF THE INSPECTION BUILDING FA... | $800 | -$11 | Aug 10, 2017 |
| Jun 20, 2017 | 37002138M | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004356 HASBEEN INSPECTED, TESTED, AND DISINFECTED, AND TH... | $2,000 | $0 | Dec 14, 2017 |
| Jun 20, 2017 | 37002139Y | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004357 HASBEEN INSPECTED,TESTED AND DISINFECTED,AND THAT ... | $2,000 | $0 | Dec 14, 2017 |
| Jun 20, 2017 | 37002140L | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004359 HASBEEN INSPECTED,TESTED AND DISINFECTED,AND THAT ... | $2,000 | $0 | Dec 14, 2017 |
| Jun 20, 2017 | 37002141N | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004361 HASBEEN INSPECTED,TESTED AND DISINFECTED,AND THAT ... | $2,000 | $0 | Dec 14, 2017 |
| Jun 20, 2017 | 37002142P | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004362 HASBEEN INSPECTED,TESTED AND DISINFECTED,AND THAT ... | $2,000 | $0 | Dec 14, 2017 |
| Jun 20, 2017 | 37002143R | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004367 HASBEEN INSPECTED,TESTED AND DISINFECTED,AND THAT ... | $2,000 | $0 | Aug 23, 2018 |
| Dec 11, 2015 | 36023706H | ACTIVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBE... | $400 | $0 | May 26, 2016 |
| Sep 10, 2013 | 34778648L | RESOLVE | CLASS - 1 | CONSTRUCTION DOCUMENTS. SCOPE. ON 10.28.10, MR. KAHANE FILED A SET OF ALT TYPE 2 DRAWINGS FOR "EXTERIOR LOCAL LAW 11 ... | $0 | $0 | Jan 16, 2014 |
| Sep 10, 2013 | 34778647J | ACTIVE | CLASS - 1 | ON 2.17.12, MR. KAHANE FILED AN "UNSAFE" FISP REPORT FOR FACADE OF 2 E61ST ST PER A/C 28.302.3 MAINTENANCE OF EXT WAL... | $1,200 | $0 | Dec 19, 2013 |
| Jan 8, 2013 | 35001650Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN FACADE AND APPURTENANCES NOTED: AT MULTIPLE LOCATIONS CRACKED MASONRY FACADE UNITS WERE OBSERVED ... | $250 | $0 | Mar 14, 2013 |
| Mar 15, 2012 | 34944034H | RESOLVE | CLASS - 2 | FAILED TO NOTIFY DEPT/OBTAIN PERMIT PRIOR TO USE/INST OFF OUTRIGGER BEAMS IN CONNECTION WITH SUSPENDED SCAFFOLDS. NOT... | $800 | $0 | May 3, 2012 |
| Aug 25, 2011 | 34898445H | RESOLVE | CLASS - 1 | SEC. 3314.1.2 NOTIFICATION OF SCAFFOLDING ACCIDENTS. THE PERMIT HOLDEROR PERSON DIRECTLY IN CHARGE OF ANY SCAFFOLDING... | $0 | $0 | Dec 1, 2011 |
| Aug 9, 2011 | 34921917J | RESOLVE | CLASS - 1 | FAILURE TO SAFE GUARD PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATION PARTIAL STOP WORK ORDER ISSUED PURSUANT ... | $2,400 | $0 | Sep 22, 2011 |
| Aug 9, 2011 | 34921918L | RESOLVE | CLASS - 2 | BC3310.3)FAILURE TO COMPLY W/ SAFETY PLAN & PROGRAM.NOTE:@ TIME OF INSPEC UPON REQUEST NO SAFETY LOG BOOK WAS PRESENT... | $0 | $0 | Sep 29, 2011 |
| Mar 5, 2011 | 34893802Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMMS ORDER TO FILE A CERT OF CORRECTION W/ THE DOB NOTED RESPONDENT FAILED TO COMPLY W/ THE... | $0 | $0 | Apr 21, 2011 |
| Dec 11, 2010 | 34878567H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLAINT MANNER. NOTED: AT ROOF TOP LEVEL A/C CHILLER UNIT LEAKING WATER & CA... | $0 | $0 | Apr 21, 2011 |
| Jan 27, 2010 | 36012350M | ACTIVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT/ENGINEER REPORT CERTIFYING EXIT/DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURC... | $4,000 | $0 | Nov 4, 2010 |
| Jun 30, 2009 | 34744981J | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. @ TIME OF INSPECTION I NOTICE THAT THE MASTER PLUMBER TILED THIS JOB UNDER HIS MASTER PLUMBING LIC... | $800 | $0 | Jul 22, 2010 |
| Jul 13, 2005 | 38153926H | RESOLVE | Non-Hazardous | 63M07/40T07/56D06/12Q03/03D06/85BB05.(63) NEW YORK CITY DEVICE NUMBER MISSING FROM MACHINE DISCONNECT SWITCH.(40) ELE... | $180 | $0 | Sep 1, 2005 |
| Jul 12, 2005 | 38153398N | RESOLVE | Non-Hazardous | 85BB05/51A#/63M07/03D06.(85) CURRENT 5 YEAR TEST TAG HAS EXPIRED.(51) HOIST ROPE INDICATING EARLY SIGN OF ROUGING.(63... | $180 | $0 | Sep 1, 2005 |
| Jul 12, 2005 | 38153925X | RESOLVE | Non-Hazardous | 63M07/05#10.(63) NEW YORK CITY ELEVATOR DEVICE NUMBER IS MISSING FROM THE MACHINE DISCONNECT SWITCH.(05) ELEVATOR CAR... | $180 | $0 | Sep 1, 2005 |
| Jul 12, 2005 | 38153397L | RESOLVE | Non-Hazardous | 85BB05/66O02/38O02.(85) CURRENT FIVE YEAR TEST TAG HAS EXPIRED.(66) ELEVATOR PIT IS DIRTY,HAS ACCUMULATED PAPER AND O... | $180 | $0 | Sep 1, 2005 |
| Jul 12, 2005 | 38153396J | RESOLVE | Non-Hazardous | 85BB05/03D06.(85) CURRENT 5 YEAR TEST TAG HAS EXPIRED.(03) HAND RAILS IN CAB ARE LOOSE. | $180 | $0 | Sep 1, 2005 |
| Jul 12, 2005 | 38153399P | RESOLVE | Non-Hazardous | 85BB05/39D06. (85) CURRENT 5 YEAR TEST TAG HAS EXPIRED.(39) MAIN AND SECONDARY MACHINE ROOM FLOOR GRATINGS ARE UNSECU... | $180 | $0 | Sep 1, 2005 |
| Jul 6, 2005 | 38153392M | RESOLVE | Non-Hazardous | 63M07/85BB05/59Q03/59L10/03D06/66O02/38O02/64L10 63) NEW YORK CITY DEVICE NUMBER IS MISSING FROM MAIN LINE DISCONNECT... | $180 | $0 | Aug 25, 2005 |
| Jul 6, 2005 | 38153394X | RESOLVE | Non-Hazardous | 63M07/85BB05/66O02/38O02/64L10/03D06/58#11/39D06 63) NEW YORK CITY DEVICE NUMBER IS MISSING FROM MACHINE DISCONNECT S... | $350 | $0 | Aug 25, 2005 |
| Jul 6, 2005 | 38153393Y | RESOLVE | Non-Hazardous | 63M07/59Q03/85BB05/03D06 63) NEW YORK CITY DEVICE NUMBER IS MISSING FROM HOIST MACHINE AND MAIN LINE DISCONNECT SWITC... | $180 | $0 | Aug 25, 2005 |
| Jul 6, 2005 | 38153395H | RESOLVE | Non-Hazardous | 85BB05/66O02/38O02/40D06/03D06/11L10/01A10/02A10 85) CURRENT FIVE YEARTEST TAG HAS EXPIRED. 66) ELEVATOR PIT HAS ACCU... | $180 | $0 | Aug 25, 2005 |