Skip to content

ECB violations

Frick Collection, Manhattan • Block 01385 • Lot 0001

21 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Sep 12, 2023 39521623N RESOLVE CLASS - 2 ACTIVE JOBSITE, I OBSERVED IN PLACES ON ROADWAY WITH INSTALLED YODOCK INCLUDING YODOCK WITH MESH SCREENS IN MULTIPLE ... $0 $0 Nov 16, 2023
Feb 5, 2022 35639657J RESOLVE CLASS - 1 BC3307.4.7 WORK OR STORAGE ZONES.AT THE TIME OF INSPECTION I OBSERVED INADEQUATE BARRIERS AT WORK OR STORAGE ZONE AT ... $625 $0 May 5, 2022
Feb 5, 2022 35639656H RESOLVE CLASS - 1 BC3303.12.4 FAILURE TO CONVERT ELEVATOR TO CONSTRUCTION OPERATION USE.AT THE TIME OF INSPECTION OF 8 STORY ALT 1 JOBS... $2,500 $0 May 5, 2022
Jan 26, 2022 35636798J RESOLVE CLASS - 2 PERMIT/NONE:ATO MY INSP OF 9STYALT.I OBSERVED NEEDLE BEAM SYSTEM@9FL LEVEL ABOVE ADJ PROPERTY ROOF&@EXP1,3,4,&AFTER R... $0 $0 Apr 28, 2022
Jan 21, 2022 35633299L RESOLVE CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-MISSING AND INADEQUATE GUARDRAILS.A... $2,500 $0 Jul 7, 2022
Jan 21, 2022 35641902R RESOLVE CLASS - 1 FAILURE TO DESIGNATE AND/OR HAVE A CONSTRUCTION SUPERINTENDENT PRESENTAT SITE AS REQUIRED.AT THE TIME OF MY INSPECTIO... $0 $0 Jul 7, 2022
Jan 21, 2022 35641900N RESOLVE CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33(SUPPORTED SCAFFOLD LOGBOOK).AT THE TIME OF MY ... $0 $0 Apr 21, 2022
Jan 21, 2022 35641901P RESOLVE CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.AT THE TIME OF MY INSPECTION ON AN ACTIVE JOBSITE ... $0 $0 Apr 21, 2022
Jan 21, 2022 35633298J RESOLVE CLASS - 1 BC 3314.9.2 FAILURE TO ERECT AND MAINTAIN SUPPORTED SCAFFOLD AS PER CODE-FOUNDATION(MISSING MUDSILLS).AT THE TIME OF ... $625 $0 Jul 7, 2022
Jan 21, 2022 35633297H RESOLVE CLASS - 1 BC 3301.6 DESIGN,SIZES,AND CAPACITY OF MATERIALS,STRUCTURES TEMPORARY CONSTRUCTION AND EQUIPMENT(NO DESIGN DRAWINGS).... $0 $0 Jul 7, 2022
Jul 27, 2021 35547429J RESOLVE CLASS - 1 HOUSEKEEPING POORLY MAINTAIN. EXISTING 9 STORY BUILDING NOTE AT THE TIME OF INSPECTION I OBSERVED ACTIVE CONSTRUCTION... $2,530 $0 Oct 14, 2021
Sep 21, 2015 37000223H RESOLVE CLASS - 2 28-317.3 FAILURE TO REGISTER COOLING TOWER.REM COMPLY W/ CODE. $0 $0 Nov 12, 2015
Jun 26, 2001 38117333Y RESOLVE Non-Hazardous ELEVATOR PART 46 VIOLATING CONDITION H SUGGESTED REMEDY HOIST CABLES $0 $0 Aug 16, 2001
Jul 11, 2000 38106336X RESOLVE Non-Hazardous 73X07,57Z09.73-DEVICE IS NON-OPERATIONAL.57-PIT LESS WATER. $0 $0 Sep 21, 2000
Aug 5, 1999 38089185X RESOLVE Non-Hazardous 74,57Y,73T. REPAIR OIL LEAK ON PITON, REMOVE OIL IN PIT. PROVIDE CITY NUMBER ON ALL EQUIPTMENT. $350 $0 Mar 16, 2000
Aug 5, 1999 38089184Y RESOLVE Non-Hazardous 30P,57P,43T. ACCESS, PROVIDE. DEVICE FOR TWO YEAR TEST. $350 $0 Mar 16, 2000
Aug 5, 1999 38089183M RESOLVE Non-Hazardous 1L,57Z. REPAIR TOGGLE SWITCH ON EMERGENCY STOP, WATER IN PIT. $350 $0 Mar 16, 2000
Sep 21, 1994 38043787J RESOLVE Non-Hazardous 73X RETURN TO SERVICE OR FILE WITH THIS DEPT FOR DISMANTLE $500 $0 Dec 8, 1994
Apr 28, 1993 38033176L RESOLVE Non-Hazardous 03Q 05Q 06Q 05Q 06Q 26B 02B 37B 02B 74 A SUBBSMT PROVIDE ELECT CONTACT ON EXISTING GATE 74 AT 1ST BSMT PROVIDE CONTAC... $0 $0 Aug 5, 1993
Apr 9, 1993 38030121K RESOLVE Hazardous 74#,28#,73#.(73)REPAIR ANY DAMAGE DUE TO ACCIDENT (74)CEASE USE UNTEL SAFETY DEVICE HAVE BEEN TESTED IN THE PRESENT O... $0 $0 Aug 5, 1993
Feb 28, 1989 34012879J RESOLVE Hazardous FAILURE TO HAVE APPROVED P.A. PLANS AVALABLE FOR INSPECTION. REMEDY: PROVIDE APPROVE P.A. PLANS. $0 $0 Apr 13, 1989