| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 27, 2014 | 38231850L | RESOLVE | CLASS - 2 | 34I04. 34I04-PATCH HOLES IN SHAFTWAY. | $0 | $0 | Aug 14, 2014 |
| Jun 16, 2008 | 38185808N | RESOLVE | Non-Hazardous | 27-987 86M05, 36T07, 86M PERFORM & FILE CURRENT 2 YR TEST 36T PROVIDE LABEL ON OVER HEAD DOOR | $0 | $0 | Aug 7, 2008 |
| Jan 29, 2008 | 34418074M | RESOLVE | Hazardous | LOCAL LAW REPORT WAS FILED AS "UNSAFE,UNSAFE CONDITIONS EXIST & NO MEASURES TAKEN TO SECURE SAFETY OF PUBLIC AS PER 2... | $0 | $0 | Jun 19, 2008 |
| Jul 17, 2007 | 38168022R | RESOLVE | Non-Hazardous | 86T05,36T07,55Y10,66O02.LL10/FAILED-86T05-2YR FILE TEST PERFORM.36T07-OVERHEAD DOOR(S)LABEL.55Y10-HOIST MACHINE OILED... | $0 | $0 | Sep 13, 2007 |
| Aug 8, 2003 | 38140296J | RESOLVE | Non-Hazardous | 53BB12,74B14,44M13,03B07. 53 RESEARCH CAR COUNTER WEIGHT CABLES. 74 SHORTN CABLES TO PROVIDE PROPER COUNTERWEIGHT RUN... | $0 | $0 | Sep 25, 2003 |
| Oct 2, 2002 | 38125926J | RESOLVE | Non-Hazardous | 27Q3-31Q3-18Q3. 27-Q-3 COVER TOP FINAL LIMIT 31-Q-3 HALF WAY BOXES A UNDER CAR BOXES MISSING COVERS. 18-Q-3 13 FLOOR ... | $0 | $0 | Nov 21, 2002 |
| Dec 26, 2000 | 38110068K | RESOLVE | Non-Hazardous | 75B16 19L11 75B-PROVIDE TAG ON GOVERNOR.19L-REPAIR PARKING DEVICE. | $0 | $0 | Feb 15, 2001 |
| Oct 16, 1999 | 38091254N | RESOLVE | Non-Hazardous | 47B15,50Y14. 47- SHORTEN GOVERNOR CABLE. #50- CHANGE PACKING GLAND ON MACHINE PREVENT OIL LEAK | $0 | $0 | Dec 9, 1999 |
| Jun 2, 1999 | 34211458N | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLANS. NON-CONFORMING WORK. NOTED:APPLICATION #101653391. DECREASING SIZE OF DOORS ... | $130 | $0 | Jul 22, 1999 |
| Feb 25, 1999 | 34195069M | RESOLVE | Non-Hazardous | INSULATION MATERIALS USED AT 13 S PENTHOUSE EXTERIOR WALLS IS NOT AN APPROVED MEA TYPE MATERIAL. IN THAT THE SAID INS... | $0 | $0 | May 13, 1999 |
| Feb 25, 1999 | 34205866L | RESOLVE | Non-Hazardous | MAXIMUM RISER HEIGHT & MINIMUN TREAD WITDTH IN J-3 BUILDINGS MUST BE 8/1/4 INCHES HIGH & 9 INCHES + 1/2 INCH WIDE FOR... | $0 | $0 | Jul 15, 1999 |
| Feb 17, 1999 | 34205853M | RESOLVE | Non-Hazardous | INSULATION MATERIALS USED IN RENOVATING 13S PNTHOUSE EXTERIOR WALLS IS NOT AN APPROVED M E A TYPE MATERIAL PER N Y CI... | $0 | $0 | May 13, 1999 |
| Nov 25, 1998 | 34186288H | RESOLVE | Non-Hazardous | INSULATION MATERIALS USED AT 13N PENTHOUSE EXTEIOR WALLS IS NOT APPRO-VED MEA TYPE. IN THAT THE SAID INSULATION MATER... | $0 | $0 | Mar 4, 1999 |
| Nov 2, 1998 | 38080937Z | RESOLVE | Non-Hazardous | 48B13,49B13. | $0 | $0 | Dec 24, 1998 |
| Oct 30, 1998 | 34157592J | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLANS. NON-CONFORMING WORK NOTED: LOCATION SIZE OF FIRE ESCAPE IS DIFFERENT THEN SH... | $250 | $0 | Mar 4, 1999 |
| Jul 28, 1998 | 34178506R | RESOLVE | Hazardous | PLUBMING WORK WITHOUT A PERMIT. NOTED KITCHEN AND BATHROOM DEMOLISHED.STEAM LINES REMOVED AND BEING REROUTED NEW 4" A... | $800 | $0 | Nov 19, 1998 |
| Jul 28, 1998 | 34178507Z | RESOLVE | Hazardous | ELECTRICAL WORK WITHOUT A PERMIT. NOTED CIRCUIT BREAKER PANEL REMOVED NEW BX CABLE INSTALLED AT DIFFERENT LOCATIONS. ... | $800 | $0 | Nov 19, 1998 |
| May 13, 1998 | 34175880N | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLANS R-4 DATED DECEMBER 6,1997 CERTIFIED UNDER DIRECTIVE 14/1975. WORK NOTED: INST... | $250 | $0 | Sep 10, 1998 |
| May 13, 1998 | 34175883Z | RESOLVE | Hazardous | FAILURE TOMAINTAIN. DEFETC NOTED: THE CANOPY WOODEN STRUCTURE EXPOSE AND THE CEMENT PLASTER CEILING IS MOVING AWY FRO... | $800 | $0 | Sep 10, 1998 |
| May 13, 1998 | 34175882R | RESOLVE | Hazardous | FAILURE TO MAINTAIN. DEFECT NOTED: A STRUCTURE APPROX. 3'-0" X 18'-0" HIGH ERECTED WITH WOOD MATERIALS ENCLOSED WITH ... | $0 | $0 | Sep 10, 1998 |
| May 13, 1998 | 34175881P | RESOLVE | Non-Hazardous | WORK DOES NOT CONFORM TO APPROVED PLAN DETALE 07535-20 DWGHR-5. WORK NOTED: SECTION OF THE BASE FLASHING APPROX 7'-0"... | $250 | $0 | Sep 10, 1998 |
| Dec 17, 1997 | 34168445N | RESOLVE | Hazardous | FAILURE TO PROVIDE AT LEAST TWO MEANS OF EGRESS FORM ROOM OR SPACE WHERE REQUIRED, NOTED: AT LOWER LEVEL OF APT 13S, ... | $480 | $0 | Feb 11, 1999 |
| Dec 17, 1997 | 34168444L | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT NOTED REMOVAL OF FEW RESISTANT PROOF EXTERIOR WALL SHINGLES ON ROOF LEVEL STRUCTER EXPOSED REMO... | $500 | $0 | Feb 12, 1998 |