Issued Violation Status Severity Description Penalty Balance due Hearing
Jan 6, 2012 34898022X RESOLVE CLASS - 1 LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQUIREMENTS. NOTED:THE FOLLOWING WORKERS ON RIGGING THA... $1,600 $0 Apr 5, 2012
Jan 6, 2012 34898020M RESOLVE CLASS - 2 FAILED TO NOTIFY DEPARTMENT/OBTAIN PERMIT PRIOR TO USE/INST OFF "C" HOOKS IN CONNECTION WITH SUSPENDED SCAFFOLDS. NOT... $400 $0 Apr 5, 2012
Jan 6, 2012 34898021Y RESOLVE CLASS - 1 RIGGER FAILED TO DESIGNATED A FOREMAN. NOTED:NO RIGGING FOREMAN ON SITE WHILE RIGGING WAS IN USE. A MR. JOSE REYES DI... $400 $0 Apr 5, 2012
Apr 10, 2007 34572041L RESOLVE Non-Hazardous FAILURE TO COMPLY W/ PROTECTIVE RAILING HEIGHT REQUIREMENTS: DEFECTS NOTED: AT 10 FL TERRACE NORTH SIDE OF BLDG TERRA... $2,500 $0 May 31, 2007
Apr 10, 2007 34572042N RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR DEFECTS NOTED: AT 10TH FL TERRACE NORTH SIDE,PLUMBING STACK VENT PIPES AFFIXED TO APT BU... $2,500 $0 May 31, 2007
Dec 19, 2006 34560050P RESOLVE Hazardous OPERATION OF A CRANE,DERRICK OR HOISTING EQUIPMENT IN AN UNSAFE MANNEROBSERVED @ TIME OF INSPECTION DUE TO IMPROPER C... $0 $0 Aug 16, 2007
Dec 19, 2006 34560051R RESOLVE Hazardous SECT.27-1045.ALL SUSPENSION ELEMENTS ARE VERTICAL & INPARALLEL TO THE WALL AT ALL TIMES.(ROPES & CABLES CANNOT JUMP O... $0 $0 Aug 16, 2007
Dec 19, 2006 34560052Z RESOLVE Hazardous SECT.27-1055.ROPES & CABLES SHALL NOT BE MADE FAST TO SHARP OBJECTS ORSURFACES OBSERVED @ TIME OF INSPECTION THE TWO ... $0 $0 Aug 16, 2007
Dec 19, 2006 34560053K RESOLVE Hazardous SEC.27-1042.ALL SCAFFOLDS SHALL BE ERECTED & MAINTAINED SO THAT THE SAFETY OF THE PUBLIC & PROPERTY WILL NOT BE IMPAI... $0 $0 Aug 16, 2007
Dec 19, 2006 34560055Y RESOLVE Hazardous NO TOE BOARD ON A TWO POINT SUSPENSION SCAFFOLD OBSERVED @ TIME OF INSPECTION NO TOE BOARD ON SCAFFOLD. $0 $0 Aug 16, 2007
Dec 19, 2006 34560056X RESOLVE Hazardous NO CENTER IRON ON A TWO POINT SUSPENSION SCAFFOLD OBSERVED @ TIME OF INSPECTION THERE IS NO CENTER IRON EXISTING ON A... $0 $0 Aug 16, 2007
Dec 19, 2006 34560057H RESOLVE Hazardous FAILURE TO OBTAIN PROPER PERMITS (CD5 FOR OUTRIGGER BEAMS)OBSERVED AT TIME OF INSPECTION THERE WAS NO CD5 PERMITS W/ ... $0 $0 Aug 16, 2007
Dec 19, 2006 34560058J RESOLVE Hazardous APPROVED PLANS NOT AVAILABLE FOR INSPECTION OBSERVED @ TIME OF INSPECTION THERE IS NO APPROVED PLANS ON JOBSITE &/OR ... $0 $0 Aug 16, 2007
Dec 19, 2006 34560059L RESOLVE Hazardous USE OF A TWO POINT SUSPENSION SCAFFOLD W/ STIRRUPS PLACED APPROXIMATE LY TWO FEET FROM THE END OF THE PLATFORM.OBSERV... $0 $0 Aug 16, 2007
Dec 19, 2006 34560060Z RESOLVE Hazardous USE OF RIGGING EQUIPMENT W/O PROPER DANGER SIGNS OBSERVED @ TIME OF INSPECTION TWO POINT SCAFFOLD HANGING OVER A PUBL... $0 $0 Aug 16, 2007
Dec 19, 2006 34560061K RESOLVE Hazardous LICENSED RIGGER DESIGNATED AN UNQUALIFIED FOREMAN OBSERVED @ TIME OF INSPECTION THERE IS NO QUALIFIED FOREMAN ON JOBS... $0 $0 Aug 16, 2007
Dec 19, 2006 34560062M RESOLVE Hazardous LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKERS MET MINIMUM REQUIRE MENTS.OBSERVED AT TIME OF INSPECTION THERE IS N... $0 $0 Aug 16, 2007
Dec 19, 2006 34560063Y RESOLVE Hazardous SUPERVISION OR USE OF RIGGING EQUIPMENT W/O A SPECIAL RIGGERS LICENSE OBSERVED @ TIME OF INSPECTION THERE IS NO SPECI... $0 $0 Aug 16, 2007
Dec 19, 2006 34560064X RESOLVE Hazardous OPERATION OF A CRANE OR HOISTING EQUIPMENT IN AN UNSAFE MANNER. OBSERVED AT TIME OFINSP DUE TO IMPROPER CABLE ATTACHM... $4,000 $0 Aug 16, 2007
Dec 19, 2006 34560065H RESOLVE Hazardous SEC. 27-1045. ALL SUPERVISION ELEMENTS ARE VERTICAL AND IN PARALLEL TOTHE WALL AT ALL TIMES.(ROPES AND CABLES CANNOT ... $500 $0 Aug 16, 2007
Dec 19, 2006 34560066J RESOLVE Hazardous SEC.27-1055. ROPES AND CABLES SHALL NOT BE MADE FAST TO SHARP OBJECTS,OR SURFACES. OBSERVED AT TIME OF INSPECTION THE... $500 $0 Aug 16, 2007
Dec 19, 2006 34560067L RESOLVE Hazardous SEC.27-1042 ALL SCAFFOLDS SHALL BE ERECTED & MAINTAINED SO THAT THE SAFETY OF THE PUBLIC & PROPERLY WILL NOT BE IMPAI... $500 $0 Aug 16, 2007
Dec 19, 2006 34560068N RESOLVE Hazardous SEC.27-1046(E)(2) TWO OR MORE TWO POINT SUSPENSION SCAFFOLD COMBINED INTO ONE BY BRIDGING THE DISTANCE B/W THEM OR BY... $500 $0 Aug 16, 2007
Dec 19, 2006 34560069P RESOLVE Hazardous NO TOEBOARDS ON A 2 POINT SUSPENSION SCAFFOLD. OBSERVED AT TIME OF INSPECTION NO TOE BOARDS ON SCAFFOLD. $750 $0 Aug 16, 2007
Dec 19, 2006 34560070M RESOLVE Hazardous NO CENTER IRON ON TWO POINTS SUSPENSION SCAFFOLD OBSERVED AT TIME OF INSPECTION THERE IS NO CENTER IRON EXISTING ON A... $750 $0 Aug 16, 2007
Dec 19, 2006 34560071Y RESOLVE Hazardous FAILURE TO OBTAIN PROPER PERMITS (CD5 FOR OUTRIGGER BEAMS) OBSERVED ATTIME OF INSPECTION THERE WAS NO CD5,PERMIT W/ T... $500 $0 Aug 16, 2007
Dec 19, 2006 34560072X RESOLVE Hazardous APPROVED PLANS NOT AVAILABLE FOR INSPECTION.OBSERVED AT TIME OF INSPECTION THERE IS NO APPROVED PLANS ON JOB SITE AND... $500 $0 Aug 16, 2007
Dec 19, 2006 34560073H RESOLVE Hazardous SEC.27-1046 USE OF A TWO POINT SUSPENSION SCAFFOLD W/ STIRRUPS PLACED APPROX. TWO FT FROM THE END OF THE PLATFORM. OB... $500 $0 Aug 16, 2007
Dec 19, 2006 34560074J RESOLVE Hazardous USE OF RIGGING EQUIPMENT W/O PROPER DANGER SIGNS.OBSERVED AT TIME OF INSPECTION TWO POINT SCAFFOLD HANGING OVER A PUB... $500 $0 Aug 16, 2007
Dec 19, 2006 34560075L RESOLVE Hazardous LICENSED RIGGER DESIGNATED AN UNQUALIFIED FOREMAN. OBSERVED AT THE TIME OF THE INSPECTION THERE IS NO QUALIFIED FOREM... $500 $0 Aug 16, 2007
Dec 19, 2006 34560076N RESOLVE Hazardous LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKERS MET MINIMUM REQUIREMENTS.OBSERVED AT THE TIME OF INSPECTION THERE I... $500 $0 Aug 16, 2007
Dec 19, 2006 34560077P RESOLVE Hazardous SUPERVISION OR USE OF RIGGING EQUIPMENT W/O A SPECIAL RIGGERS LICENSE.OBSERVED AT TIME OF INSP THERE IS NO SPECIAL RI... $500 $0 Aug 16, 2007
Sep 24, 2003 34416486J RESOLVE Non-Hazardous FAILURE TO SUBMINT A FIFTH ROUND TECHINCAL REPORT PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $0 $0 Apr 29, 2004
Mar 3, 2003 34384396M RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... $0 $0 Mar 18, 2004
Oct 16, 2000 34257607L RESOLVE Non-Hazardous PLUMBING WORK WITHOUT A PERMIT. (INSTALLING GAS PIPE + METER BAR WITH OUT A PERMIT.) REMEDY:OBTAIN A PERMIT IF FEASIB... $800 $0 Nov 30, 2000
Dec 10, 1997 38067174N RESOLVE Non-Hazardous 03O,25O,30O, $0 $0 Feb 5, 1998