| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 4, 2014 | 36019629L | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXT... | $0 | $0 | Jan 8, 2015 |
| Nov 27, 2007 | 38180018X | RESOLVE | Non-Hazardous | 55Y10,55O02,86BB05,39O02,38O02,66O02,84X10,86BB05. 55-Y HOIST MACHINE OILED,REPAIR,SEAL & CLEAN. 39-O CLEAN MOTOR ROO... | $180 | $0 | Jan 17, 2008 |
| Jan 24, 2005 | 38156621K | RESOLVE | Non-Hazardous | #M07/#M07 #-FIRE EXTINGUSHER (MOUNTED)IS MISSING FORM MACHINE ROOM # SMIE DIRECTOR IS MISSING FORM MACHINE ROOM | $180 | $0 | Jul 28, 2005 |
| Oct 15, 2001 | 38119401X | RESOLVE | Non-Hazardous | 3MT, 5J11, 31Q3, 55X4, 3M7-CAPACITY PLATE 5J11- TOO MUCH GAP TO POST 31Q3- CAR TOP | $0 | $0 | Nov 29, 2001 |
| Oct 15, 2001 | 38118774Y | RESOLVE | Non-Hazardous | 5J11, 9H12, 15L11, 16H12, 31Q3, 50Y14, 55X11, 60U5, 74M7, 5J11=TOO MUCH GAP TO POST 15L11= NOT SELF CLOSING 1&PH, 16H... | $0 | $0 | Nov 29, 2001 |
| Jun 26, 2001 | 38116308H | RESOLVE | Non-Hazardous | 40O02-74M07-40M14. 74-M-07 AS PER RULE 27-1004A & B 40-M-14 PROPEALY SEAL GOV. | $180 | $0 | Sep 25, 2001 |
| Jun 26, 2001 | 38116309J | RESOLVE | Non-Hazardous | 40M14-74M07-40O02. 40-M-14 PROPERLY SEAL GOV. 74-M-07 AS PER RULE 27-1004A. | $180 | $0 | Aug 16, 2001 |
| Jun 26, 2001 | 38116310R | RESOLVE | Non-Hazardous | 40O02-40M14. 40-M-14 PROPERLY SEAL GOV. | $180 | $0 | Sep 25, 2001 |
| Nov 8, 1997 | 38065162R | RESOLVE | Non-Hazardous | 54M7, 36T7, 54D6, 55I11, 56M7, 57O2, 74M7. PROVIDE GROUND IN MAIN LINE. LABEL MOTOR ROOM DOOR SECURE MAIN LINE SWITCH... | $0 | $0 | Jan 22, 1998 |
| Nov 8, 1997 | 38065163Z | RESOLVE | Non-Hazardous | 54M7, 36T7, 54D6, 55I11, 56M7, 57O2, 74M7. PROVIDE GROUND IN MAIN LINE SWITCH. LABEL MOTOR ROOM DOOR. SECURE MAIN LIN... | $0 | $0 | Jan 22, 1998 |
| Nov 8, 1997 | 38065164K | RESOLVE | Non-Hazardous | 54M7, 36T7, 54D6, 55I11, 56M7, 57O7, 74M2, 22D6. PROVIDE GROUND IN MAIN LINE SWITCH. LABEL MOTOR ROOM DOOR. | $0 | $0 | Jan 22, 1998 |
| Jul 27, 1994 | 38044730N | RESOLVE | Non-Hazardous | 73H RENEW CAR DOOR SILL(TRACKS) + HOIST DOOR SADDLES | $100 | $0 | Dec 1, 1994 |
| Jul 27, 1994 | 38044731P | RESOLVE | Non-Hazardous | 73H 73)RENEW CAR DOOR SADDLE AND HOIST DOORS SADDLES | $0 | $0 | Dec 1, 1994 |
| Jul 27, 1994 | 38044732R | RESOLVE | Non-Hazardous | 73H 73 RENEW CAR DOOR SADDLE AND HOISTWAY DOORS SADDLES | $100 | $0 | Dec 1, 1994 |
| Jul 11, 1994 | 34113081N | RESOLVE | Non-Hazardous | WORK WITHOUT APERMIT. WORK NOTE: INSTALLATION OF EXHAUST FAN & DUCT WORK IF LAUNDRY ROOM WINDOW AT CELLAR LEVEL FRONT... | $175 | $0 | Aug 25, 1994 |