ECB violations
1372 York Avenue, Manhattan • Block 01485 • Lot 0002
21 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 16, 2012 | 34947630H | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. WORK NOTED: AT CELLAR LEVEL NEW OPENING IN FOUNDATION PARTY WALL INTO ADJACENT BLDG 1374 APPROX 3'... | $0 | $0 | Jun 13, 2012 |
| Feb 16, 2012 | 34947629K | RESOLVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BUILDING DEPT RECORDS. ILLEGAL OCCUPANCY NOTED: CELLAR OCCUPANCY AS AN OFFI... | $0 | $0 | Apr 12, 2012 |
| Feb 16, 2012 | 34947633N | RESOLVE | CLASS - 2 | SEC. 1208 FAILURE TO PROVIDE MINIMUM INTERIOR SPACE DIMENSIONS FOR MABITABLE ROOMS NOTED: 2 FRONT BEDROOMS IN APTS #2... | $0 | $0 | Apr 12, 2012 |
| Feb 16, 2012 | 34947631J | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSTRUCTION NOTED: REAR EXIT PASSAGEWAY INTO E 73RD ST EXIT DISCHARG... | $0 | $0 | Jun 7, 2012 |
| Feb 16, 2012 | 34947632L | RESOLVE | CLASS - 1 | UNSAFE STORAGE OF COMBUSTIBLE MATERIALS & EQUIPMENT. NOTED: AT REAR YARD STORED WOODEN CONSTRUCTION MATERIALS AS PLAN... | $2,400 | $0 | Jun 13, 2012 |
| May 4, 2011 | 34907318R | RESOLVE | CLASS - 1 | OCCUPANCY CONTRARY TO THAT ALLOWED BY DOB RECORDS.ILLEGAL OCCUPANCY NOTED:CLASS 'A' APT CONVERTED INTO TRANSIENT HOTE... | $0 | $0 | Oct 10, 2013 |
| May 4, 2011 | 34907320X | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.DEFECTS NOTED:DROP LADDER FROM FIRE ESCAPE FRONT OBSTRUCTED BY AWNING... | $0 | $0 | Oct 10, 2013 |
| May 4, 2011 | 34907323L | RESOLVE | CLASS - 2 | ILLEGAL USE IN RESIDENTIAL DISTRICT.BLDG OCCUPIED AS A TRANSIENT HOTEL IN APT#1A,1B,2A,2B,1C,3A,3C,4A,4B,4C IN R10 RE... | $0 | $0 | Oct 10, 2013 |
| May 4, 2011 | 34907324N | RESOLVE | CLASS - 1 | WORK W/O PERMIT.WORK NOTED:IN APTS# 1A,1B,1C,2A,2B,3A,3C,4A,4B,4C ERECT FULL HEIGHT PARTITIONS TO CREATE EXTERIOR ROO... | $0 | $0 | Oct 10, 2013 |
| May 4, 2011 | 34907319Z | RESOLVE | CLASS - 1 | 1001.4)FAILURE TO PROVIDE REQUIRED MEANS OF EGRESS FROM ROOM OR SPACE.ROOMS#1A,1B,2A,2B,1C,3A,3C,4A,4B,4C OCCUPIED AS... | $0 | $0 | Mar 6, 2014 |
| May 4, 2011 | 34907325P | RESOLVE | CLASS - 1 | BC907.2.8)FAILURE TO PROVIDE FIRE ALARM SYSTEM.NOTED:BLDG OCCUPIED AS A TRANSIENT HOTEL W/O PROVIDING FIRE ALARM.REM:... | $0 | $0 | Mar 6, 2014 |
| May 4, 2011 | 34907326R | RESOLVE | CLASS - 1 | BC903.2.7)FAILURE TO PROVIDE AUTOMATIC SPRINKLER SYSTEM.BLDG OCCUPIED AS A TRANSIENT HOTEL W/O PROVIDING AUTOMATIC SP... | $0 | $0 | Mar 6, 2014 |
| May 4, 2011 | 34907327Z | RESOLVE | CLASS - 1 | BC1008.1.2.2)FAILURE TO COMPLY W/ DIRECTION OF SWING.EXIT LOBBY DOORS @ GROUND FLR SWINGS AGAINST THE DIRECTION OF EG... | $0 | $0 | Mar 6, 2014 |
| May 4, 2011 | 34907328K | RESOLVE | CLASS - 1 | 1208.2)FAILURE TO COMPLY W/ MIN CEILING HEIGHTS.NOTED:CEILING HEIGHTS IN VARIOUS APTS ARE 6'1".(8"MIN REQUIRED).REM:C... | $0 | $0 | Mar 6, 2014 |
| May 4, 2011 | 34907337M | RESOLVE | CLASS - 1 | SEC. 1004.1.2 FAILURE TO COMPLY W/MAXIMUM FLOOR AREA REQUIREMENTS PER OCCUPANT LOAD. ROOMS IN APT #1A,1B,2B,2A,3A,3C,... | $0 | $0 | May 31, 2012 |
| May 4, 2011 | 34907329M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER.USE OF PROHIBITED HARDWARE PER BC1008.1.8;27-371(J).REM:PROVIDE LEG... | $0 | $0 | May 31, 2012 |
| Feb 2, 2010 | 34754577R | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAYS NOTE:AT REAR OF BLDG THERE EXIST A HORIZONTAL EXIT DISCHARGE WHICH I... | $0 | $0 | Jan 26, 2012 |
| Feb 2, 2010 | 34754578Z | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMITWORK NOTED:AT 2ND FL APT 1A FULL HEIGHT PARTITIO NS ERECTED CREATING A SEPARATION OF PLUMBING FI... | $0 | $0 | Jan 26, 2012 |
| Apr 29, 2009 | 34775186M | RESOLVE | CLASS - 2 | WORK W/O A PERMIT NOTED AT BASE LVL AT VENTILATION LIGHT SET BACK COURTYARD BTWN 1374 & 1372 YORK AV AN APPROX 10'0" ... | $0 | $0 | Jun 18, 2009 |
| Apr 29, 2009 | 34775185K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS AT CENTER VENTILATION & LIGHT SHAFT COURTYARD BTWN... | $0 | $0 | Jun 18, 2009 |
| Jan 6, 2004 | 34428026R | RESOLVE | Non-Hazardous | WORK WITHOUT A PERMIT HAVING REMOVED WOOD STRUCTURE FROM LOBBY ENTRANCE TO CELLAR AREA AN IN PROCESS OF REPLACING SAM... | $500 | $0 | Jul 15, 2004 |