ECB violations
12 East 89 Street, Manhattan • Block 01500 • Lot 0062
27 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Feb 1, 2024 | 35679717Z | RESOLVE | CLASS - 2 | REMOVAL OF PUBLIC PROTECTION FROM UNSAFE FACADE WITHOUT APPROVAL FROM THE DEPARTMENT. NOTE: AT TIME OF INSPECTION, OB... | $1,250 | $0 | Apr 11, 2024 |
| Feb 1, 2024 | 35679716R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: OBSERVED AT EXPOSURE #3(SOUTH FACADE) SPALLING ... | $1,250 | $0 | Apr 11, 2024 |
| Jan 16, 2024 | 37026515P | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITION DESCRIBED IN INTIAL FACA... | $1,250 | $0 | May 2, 2024 |
| May 20, 2020 | 35538385M | RESOLVE | CLASS - 1 | 1RCNY -103-04=OWNER FAILED TO REPAIR BUILDING EXTEIROR FACADE AND APPURTENANCES WITHIN THE RECOMMENDED COMPLETION DAT... | $2,500 | $0 | Jul 30, 2020 |
| Nov 13, 2019 | 35460512Z | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE/HAVE ON SITE CONSTRUCTION DOCUMENT REQUIRED BY CHAPTER 33(DRAWING FOR OVERHEAD PROTECTION)AT THE T... | $2,500 | $0 | May 14, 2020 |
| Jul 5, 2017 | 35288127K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. AT TIME OF INSPECTION I OBSERVED 6 STORIES, WITH ... | $2,400 | $0 | Oct 26, 2017 |
| Jul 5, 2017 | 35288126Z | RESOLVE | CLASS - 1 | 3314.4.8 SCAFFOLD ALL COMPONENT OF AND ATTACHMENTS TO THE SCAFFOLD AND ALL SUPPORT AND ANCHORAGES OF THE SCAFFOLD INS... | $1,600 | $0 | Oct 26, 2017 |
| Jun 20, 2017 | 37002135R | RESOLVE | CLASS - 2 | FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004220 HASBEEN INSPECTED, TESTED, AND DISINFECTED, AND TH... | $0 | $0 | Aug 17, 2017 |
| May 4, 2017 | 35238496K | RESOLVE | CLASS - 2 | CONCRETE WASHOUT WATER AT TIME OF INSPECTION OBSERVED CONCRETE WASHOUT WATER WAS ENTERING STREET DRAIN ON CORNER OF M... | $1,200 | $0 | Dec 21, 2017 |
| May 4, 2017 | 35238495Z | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD PERSONS & PROPERT IN RESPONSE TO AN INCIDENT WHERE A CONCRETE PUMP TRUCK THAT A MECHANICAL FAILU... | $5,000 | $0 | Dec 21, 2017 |
| May 4, 2017 | 35238497M | RESOLVE | CLASS - 2 | SEC. 3303.15.1 CONCRETE WASHOUT CONTAINER. AT TIME OF INSPECTION OBSERVED THAT THE CONCRETE WASHOUT CONTAINER IN USE ... | $1,200 | $0 | Dec 21, 2017 |
| Mar 8, 2016 | 35156999N | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION. AT THE TIME OF INSPECTION NO DOB APPROV... | $250 | $0 | Apr 28, 2016 |
| Jan 27, 2010 | 36012365P | RESOLVE | CLASS - 2 | FAIL TO FILE AN ARCHITECT/ENGINEER REPORT CERTIFYING EXIT/DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURCE/S... | $4,000 | $0 | Nov 4, 2010 |
| Oct 20, 2008 | 38192462K | RESOLVE | CLASS - 2 | 56Y10.40O02.56Y10 HOIST MACHINE LEAK OIL REPAIR 40O02 CLEAN MACHINE ROOM | $500 | $0 | Dec 11, 2008 |
| Oct 20, 2008 | 38192461Z | RESOLVE | CLASS - 2 | 100O02.08V10.56Y10.71X10.100O02 CLEAN OVERHEAD ROOM 08V10 REPAIR CAR FL TO LANDING SILL NOT LEVEL 56Y10 REPAIR HOIST ... | $500 | $0 | Dec 11, 2008 |
| Oct 15, 2003 | 32042790H | RESOLVE | Non-Hazardous | 34A 50 B4B REMOVED BY PASS FROM BALL FLOW PREVENTER BACK FLOW PREVENTOR LEAKING | $0 | $0 | Dec 4, 2003 |
| Sep 23, 2003 | 32043113P | RESOLVE | Non-Hazardous | 6A,36 6A BOILER NEEDS RELIEF VALVE | $350 | $0 | Nov 13, 2003 |
| Sep 3, 2002 | 38125196R | RESOLVE | Non-Hazardous | 8V1-15E11-15R09-31Q3-33P17-35Y2-50Y2-51B7-73U16. 15-E-11 1 FLOOR 15-R-9 LOCK ON 6 FLOOR. 51-B-7 OIL 73-U-16 TAG ALL M... | $350 | $0 | Jul 17, 2003 |
| Jul 31, 2002 | 38124525Y | RESOLVE | Non-Hazardous | 38F11/ 37L10 <<< SECOND OFFECE 37B11/ 02B11/ 50F11/ (28) ELIMINATE EXCESSIVE LOST MOTION IN CAR SHOE ( TOP & BOT ) (3... | $880 | $0 | Sep 19, 2002 |
| Jul 19, 2002 | 38124512P | RESOLVE | Hazardous | 54I10-37D01-01X07-08V01-15D09. 54-CEASE USE UNTIL MAIN DISCONNECT IS REPAIRED OR REPLACE 37-ADJUST TIMER ON CONTROLLE... | $500 | $0 | Aug 29, 2002 |
| May 21, 2002 | 34324167Y | RESOLVE | Non-Hazardous | FAILURE TO OBTAIN A PERMIT FOR TEMPORARY CONSTRUCTION: SIDEWALK SHED PERMIT# 102153599 HAS EXPIRED ON 4/1/02 AT ABOVE... | $0 | $0 | Jul 11, 2002 |
| Sep 28, 2001 | 38119183R | RESOLVE | Non-Hazardous | 75B05/ 54I10/ 53B07/ 35D09/ 37B01/ 75 - PERFORM REG. 5 YEARS TESTA 54 - REPAIR DAMAGED MIN DISCONNECT & WIRING 53 - A... | $0 | $0 | Nov 15, 2001 |
| Sep 28, 2001 | 38119184Z | RESOLVE | Non-Hazardous | 28F11-37L10-35D06 28=ELIMINATE EXCESSIVE LOST MOTION IN CAR SHOE(4) 37-ADJ ACC SW & H RELAY PROVIDE TIME TO OPEN GATE... | $0 | $0 | Nov 15, 2001 |
| Sep 28, 2001 | 38119182P | RESOLVE | Non-Hazardous | 30D06/ 30- SEAL ALL DOORS ON THIS REMOVED DEVICE ALL DOORS ARE NOW ABLE TO BE OPENED WITH KEY ( DEADLOCK CYLINDER ) | $2,500 | $0 | Feb 28, 2002 |
| Nov 28, 2000 | 38109864N | RESOLVE | Non-Hazardous | 46B15,47H12.46-PROVIDE PROPER CWT TO BUFER RUNBY CLEANER. | $0 | $0 | Jan 18, 2001 |
| Nov 28, 2000 | 38109863L | RESOLVE | Non-Hazardous | 50M7 35#9 74M7 46I12 50 M 7 WIRES WIRE NUT 35#9 NON ELEVATOR EQUIP. 74M7 M/R FIRE EXTINGUISHOR 46I12 SHACKEL SPRINGS ... | $0 | $0 | Jan 18, 2001 |
| Aug 15, 1990 | 34044377X | RESOLVE | Hazardous | FAILURE OT HAVE APPROVED PA PLAN AVAILABLE FOR INSPECTION REMEDY PROVIDE APPROVE PLAN FOR INSPECTION | $115 | $0 | Sep 27, 1990 |