Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 1, 2026 39190683L ACTIVE CLASS - 2 NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 FAILURE TO MAINTAIN VIOLATION #39116571L ISSUED 6/11/2024 CITING DOO... $1,250 $1,250 Oct 8, 2026
Mar 4, 2026 39179117J ACTIVE CLASS - 1 I OBSERVED IN APT 2E IN A MULTI FAMILY DWELLING INSTALLATION OF BOXES IN BATHROOM LIVING ROOM WITHOUT AN ELECTRICAL P... $2,530 $2,530 Jul 2, 2026
Mar 4, 2026 39179116H ACTIVE CLASS - 1 I OBSERVED UNSAFE UNSUITABLE ELECTRICAL CONDITIONS IN APT 2E IN A MULTI-FAMILY DWELLING,INSTALLATION OF BOXES IN BATH... $1,630 $1,630 Jul 2, 2026
Dec 30, 2024 39134025N RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER TO FILE A CERT OF CORRECTION WITH THE DEPT OF BUILDINGS FOR ECB VIOLATION ... $3,125 $3,125 Mar 6, 2025
Dec 30, 2024 39134022H RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER TO FILE A CERT OF CORRECTION WITH THE DEPT OF BUILDINGS FOR ECB VIOLATION ... $3,125 $3,125 Mar 6, 2025
Aug 26, 2024 37029105X RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS#39058559X ISSUED ON 3/22/2022 AND FAILURE TO FILE A ... $3,125 $3,125 Feb 6, 2025
Jun 11, 2024 39116571L ACTIVE CLASS - 1 SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE TO DOOR KNOB IN A STATE OF DISREPAIR DUE TO MISSING DOOR KNOB ON THE INSID... $1,250 $0 Aug 15, 2024
May 29, 2024 39115464L RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDERS TO FILE A CERT OF CORRECTION WITH THE DEPT OF BUILDINGS. NOTED NO CERT OF... $5,000 $3,560 Aug 8, 2024
May 29, 2024 39115474P ACTIVE CLASS - 2 WORK DOES NOT CONFORM TO APPROVED PLANS OR AMENDMENTS. NOTED JOB #123368140 WITH PERMIT ISSUED 09/24/2018 SHOW TENNAN... $6,250 $6,250 Jan 9, 2025
May 29, 2024 39115467R ACTIVE CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. USE OF PROHIBITED DOOR HARDWARE PER BC 1008. NOTED (4) BEDROOM... $3,125 $0 Aug 8, 2024
Mar 22, 2022 39058559X ACTIVE CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING RECORDS. NOTED: APT # 1E WAS RENOVATED UNDER JOB # 120508129 AND REC R... $3,125 $0 May 12, 2022
Jan 7, 2021 39034473Z RESOLVE CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPARTMENT RECORDS. JOB 120508129 IND... $0 $0 Feb 25, 2021
Aug 13, 2018 35387286L RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35329518X ISSUED ON 05/01/18 AND TO F... $3,125 $0 Nov 15, 2018
Jul 30, 2018 35387440K RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35329518K ISSUED ON 05-01-18 & TO FILE A C OF C PURSUAN... $1,250 $0 Dec 13, 2018
Jun 13, 2018 35336861Z RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35329518X ISSUED ON 05-01-18 & TO FILE A C OF C PURSUAN... $1,250 $0 Sep 27, 2018
May 1, 2018 35329519H RESOLVE CLASS - 2 WORK W/O A PERMIT. AT CELLAR LEVEL, OBSERVED AT TIME OF INSPECTION FULL HEIGHT PARTITIONS CRETING 4 BECROOM, 2 PC BAT... $1,250 $0 Aug 23, 2018
May 1, 2018 35329518X RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY OR BUILDING DEPT RECORDS. NOTED: JOB #120508129 INDICA... $1,250 $0 Aug 23, 2018
Mar 11, 2011 34890183K RESOLVE CLASS - 3 FAILURE TO MAINTAIN 3'6"GUARDRAIL OR EQUIVALENT AROUND ALL FLR & PERIMETER OPENINGS @ TIME OF INSP I DID OBSERVE @ EX... $0 $0 Apr 28, 2011
Mar 11, 2011 34890179H RESOLVE CLASS - 2 STOP ALL WORK:WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS&/OR APPROVED AMENDMENTS.@ TIME OF INSPECTION I... $0 $0 Apr 28, 2011
Mar 11, 2011 34890180P RESOLVE CLASS - 3 FAILURE TO PERFORM INSP & DOCUMENT CONDITIONS OF EXISTING STRUCTURES ADJOINING A CONSTRUCTION ON DEMO SITE IN A PRE-C... $0 $0 Apr 28, 2011
Mar 11, 2011 34890181R RESOLVE CLASS - 2 FAILURE TO POST "NO SMOKING"SIGN @ CONSTRUCTION/DEMO SITE IN VIOLATIONOF NYC FIRE CODE.@ TIME OF INSPECTION NO "NO SM... $0 $0 Apr 28, 2011
Mar 11, 2011 34890182Z RESOLVE CLASS - 3 (MISC)37-1009A/BC3303.2.4FAILURE TO PROVIDE REQUIRED TEMP OR PERMANENTSANITRAY FACILITIES DURING CONST OPERATIONS.@ T... $0 $0 Apr 28, 2011
Jan 20, 2011 34892556N RESOLVE CLASS - 2 FAILURE TO COMPLY W/COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION FOR NOV #34889450H. REMEDY: FILE CERTIFI... $0 $0 Apr 7, 2011
Nov 20, 2010 34889450H RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS:STAIRCASE LEADING FROM 1FLR TO 2FLR H... $0 $0 Feb 3, 2011
Aug 3, 2010 34852181J RESOLVE CLASS - 2 WORK W/O A PERMIT WORK NOTED: BLDG HAVING ERECTED 1 5/8 METAL STUD FRAMING FOR DROP CEILINGS (APPROX 6" DOWN) ON PUBL... $0 $0 Mar 3, 2011
May 20, 2010 34853050Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER IN THAT IN APT 1W THE BATHROOM CEILING IS DEFECTIVE SECTION HAS FAL... $0 $0 Sep 22, 2010
Apr 20, 2010 34819960Y RESOLVE CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONST OPERATION.NOTED:OWNER WAS TOLD TO PROVIDE FIRE GUARD ... $12,000 $0 Jun 10, 2010
Apr 19, 2010 34819951M RESOLVE CLASS - 1 SEC 714.1 FAILURE TO PROVIDE REQD FIRE RATINGON STRUCTURAL MEMBERS OR ASSEMBLIES.NOTED AT TIME OF INSPECTION.CONTRACT... $8,000 $0 Jun 10, 2010
Apr 19, 2010 34819954H RESOLVE CLASS - 2 FAILURE TO SAFE GUARD ALL PERSONS AND PROPERTY AFFECTED BY CONST OPERATIONS.NOTED:@ TIME OF INSPECTION CONTRACTOR FAI... $1,200 $0 Oct 14, 2010
Apr 19, 2010 34819952Y RESOLVE CLASS - 2 SEC 2810477 FAILURE TO FILE TRI FORM AND DESIGNATE OPERATION SUBJECT TO CONTROLLED INSPECTION ON PLAN PRIOR TO THE CO... $4,000 $0 Jun 10, 2010