ECB violations
1682-1690 2 Avenue, Manhattan • Block 01550 • Lot 0001
28 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 10, 2021 | 35580060N | ACTIVE | CLASS - 1 | BC 3307.6.4 DESIGN AND CONSTRUCTION OF SIDEWALK SHED.AT THE TIME OF INSPECTION I OBSERVED A SWS IN PLACE AT EXPOSURE ... | $1,250 | $0 | Mar 24, 2022 |
| Aug 10, 2021 | 35580059X | ACTIVE | CLASS - 1 | PARAPET LETTER NOT ONSITE AT THE TIME OF INSPECTION I ASKED FOR THE PARAPET LETTER FROM THE ENGINEER OF RECORD.THIS L... | $625 | $0 | Mar 24, 2022 |
| Aug 10, 2021 | 35580058Y | ACTIVE | CLASS - 1 | BC 3314.3.3 DRAWINGS.AT THE TIME OF INSPECTION I OBSERVED SUSPENDED SCAFFOLDS ONSITE.UPON FURTHER INSPECTION OF THE S... | $2,500 | $0 | Mar 24, 2022 |
| Mar 3, 2021 | 35548876X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTE:OBSERVED AT EXPOSURE 1 SOUTH ELV LOOSE/HANGING MO... | $1,250 | $0 | May 20, 2021 |
| Mar 3, 2021 | 35548875Y | RESOLVE | CLASS - 1 | FAILURE TO REPAIR SWARMP CONDTIONS IN A TIMELY MANNER.OWNER FAILED TO REPAIR DELAMINATING AND SPALLING GLAZED BRICKS ... | $2,500 | $0 | May 20, 2021 |
| Jan 21, 2020 | 35467673L | ACTIVE | CLASS - 2 | VIOLATION OF DISCRETIONARY ZONING CONDITIONS ON PRIVATELY OWNED PUBLICSPACE. AT TIME OF INSPECTION NOTED AS PER POPS#... | $5,000 | $5,000 | Nov 19, 2020 |
| Aug 29, 2018 | 35344381J | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED:UPON INSPECTION OF CELLAR BUSINESS CONGRETE JUNGLE OBSER... | $625 | $0 | Jan 10, 2019 |
| Feb 12, 2018 | 35317448L | RESOLVE | CLASS - 2 | VIOLATION OF CONDITION AS OF RIGHT PRIVATELY OWNED PUBLIC SPACE GENERAL MAINTENANCE NON COMPLIANT NYC ZONING RESOLUTI... | $0 | $0 | Jun 21, 2018 |
| Apr 20, 2015 | 35115524Z | RESOLVE | CLASS - 1 | WORK W/O A PERMIT.-INSTALLATION OF WASHER + DRYER INSPECTION TIME 12:40 ON 4/20/15,I OBSERVED IN UNIT 19C A ELECTRIC ... | $0 | $0 | Jun 4, 2015 |
| Jul 29, 2011 | 36016484X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $8,000 | $0 | Dec 15, 2011 |
| Jul 27, 2011 | 34921903Z | RESOLVE | CLASS - 2 | 3310.6)FAILURE TO HAVE DESIGNATED SSM AS INDICATED ON PW2 PRESENT ON SITE @ MIN OF ONCE EVERY 2 WEEKS.EXAMINATION OF ... | $0 | -$400 | Sep 15, 2011 |
| Oct 19, 2010 | 34837561X | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BLDG WALLS & APPURTENANCES INSECURE METAL BALCONY RAILINGS WERE FOUND @ VARIOUS FLRS (9/F 7/F 5/F... | $1,000 | $0 | Dec 9, 2010 |
| Oct 19, 2010 | 34837560Y | RESOLVE | CLASS - 1 | LOCAL LAW 6TH CYCLE REPORT FILED AS UNSAFE BY ARCHITECT ENGINEER NO AMENDED REPORT WAS FILED UNSAFE CONDITIONS REQUIR... | $1,600 | $0 | Dec 9, 2010 |
| Sep 17, 2010 | 36014891Y | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED... | $2,000 | $0 | May 5, 2011 |
| Mar 26, 2010 | 36012794N | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $8,000 | $0 | Nov 18, 2010 |
| Mar 17, 2010 | 34837111Z | RESOLVE | CLASS - 1 | SEC 27/BC- MISC 28-302.5 MISC VIOL: LOCAL LAW REPORT FILED AS "UNSAFE"BY ARCHITECT/ENGINEER; NO AMENDED REPORT WAS FI... | $8,000 | $0 | May 6, 2010 |
| Mar 17, 2010 | 34837112K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. (I)INSECURE METAL BALCONY RAILINGS WERE FOUND AT 15/F. AT NORT... | $5,000 | $0 | May 6, 2010 |
| Aug 11, 2009 | 34744376L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG. SOUTH ELEVATION OBSERVED EXPOSED REBARS IN BALCONY FACADE; EXPOSED FOOTING IN BALC... | $500 | $0 | Oct 1, 2009 |
| Jan 14, 2009 | 34753312R | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONST DOCUMENTS AND OR APPROVED AMENDMENTS NOTED SIDEWALK SHED AT EXPOSURE 2 IS APP... | $0 | $0 | Mar 5, 2009 |
| Sep 25, 2008 | 34700160H | RESOLVE | CLASS - 1 | LIFELINES TIEBACKS & SUSPENSION ROPES SHALL EACH BE ATTACHED TO A DIFFERENT POINT OF ANCHORAGE OBSERVED:THREE LIFE LI... | $1,600 | $0 | Jan 29, 2009 |
| Feb 21, 2008 | 34418654Z | RESOLVE | Hazardous | LOCAL LAW REPORT WAS FILED AS "UNSAFE" UNSAFE CONDITIONS EXIST & NO MEASURE TAKEN TO SECURE SAFETY OF PUBLIC AS PER 2... | $800 | $0 | Apr 10, 2008 |
| Oct 9, 2007 | 34605615J | RESOLVE | Hazardous | LICENSED RIGGER FAILED TO ENSURE THAT THE SCAFFOLD WORKERS MET MINIMUMREQUIREMENTS. WORKERS ON SCAFFOLD W/O CERTIFICA... | $1,500 | $0 | Mar 6, 2008 |
| Jun 10, 2003 | 38139301R | RESOLVE | Non-Hazardous | 55,Y,13 33,Y,2 10,H,11 84,H,11 17,H,11 66,0,2 33 STOP OF SHATWAY 84 CAR DOOR SADDLE WORN 17 10 FL | $180 | $0 | Jul 31, 2003 |
| Jan 16, 2001 | 38110783J | RESOLVE | Non-Hazardous | 16H12,35I11,35D6,48B15,57O2.16H12=5C,C,1,3,5,12,14 & 25FLS. 35I11=ENTRANCE WALL 35D6=STAIR RAILING. | $0 | $0 | Mar 8, 2001 |
| Jan 16, 2001 | 38110784L | RESOLVE | Non-Hazardous | 11Q3,55X11,16H12,05J11,23U16,35I11,60U5,75U5. 11Q3=CAR TOP 16H12=CELLAR FL. 05J11=TOO MUCH GAP TO POST. | $180 | $0 | Mar 8, 2001 |
| Dec 13, 2000 | 34267382Z | RESOLVE | Non-Hazardous | XAILURE TO MAINTAIN BLDG WALL. NOTED: IN APT. 6A-TERRACE WALL HAS A 1/2"CRACK FROM TERRACE LANDING TO 7TH FL., 2)RETA... | $0 | $0 | Feb 1, 2001 |
| Oct 30, 1992 | 38029441L | RESOLVE | Non-Hazardous | 04M,46H, 04-5 PIN CYLINDER | $0 | $0 | Dec 17, 1992 |
| Oct 30, 1992 | 38029440J | RESOLVE | Non-Hazardous | 04M,08V,15L,18M,24L,28L,46H,74#, 04-5 PIN CYLINDER 15-HANGERS AND/OR ROLLERS 18-DUST COVERS 28-ROLLERS 74-STEODYING P... | $0 | $0 | Dec 17, 1992 |