ECB violations
1850-1852 2 Avenue, Manhattan • Block 01558 • Lot 0050
110 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 11, 2026 | 39557773N | ACTIVE | CLASS - 1 | 3314.4.5.4 OBS. WORKER PERFORMING WORK FROM SUSPENDED SCAFFOLD W/O REQ'D 16-HR SUSPENDED SCAFFOLD USER TRAINING/CARD.... | $2,400 | $2,400 | Oct 15, 2026 |
| Aug 11, 2026 | 39557774P | ACTIVE | CLASS - 2 | 3301.1.3 OBS. SUPPORTED & SUSPENDED SCAFFOLD SYSTEMS IN USE. UPON REQUEST, CONTRACTOR FAILED TO PROVIDE MFR. SPECS FO... | $2,500 | $2,500 | Oct 15, 2026 |
| Aug 11, 2026 | 39557771J | ACTIVE | CLASS - 2 | 3314.3.4 OBS SUPPORTED SCAFFOLD INSTALLED ON TOP OF A SIDEWALK SHED. UPON REQUEST, NO ENGINEER'S LOAD-IMPOSED LETTER ... | $2,500 | $2,500 | Oct 15, 2026 |
| Aug 11, 2026 | 39557772L | ACTIVE | CLASS - 1 | OBS. FACADE WORK IN PROGRESS AT 25 STORY BLDG. UPON REQUEST, COMPETENT PERSON FAILED TO PROVIDE REQ'D DRAWINGS/CD5, P... | $2,500 | $2,500 | Oct 15, 2026 |
| Aug 11, 2026 | 39557770H | ACTIVE | CLASS - 1 | OBS. SUSPENDED SCAFFOLD IN USE AT EXP. 1 W/O DIRECT SUPERVISION OF A LICENSED RIGGER OR DESIGNATED RIGGING FOREMAN. U... | $5,000 | $5,000 | Oct 15, 2026 |
| Aug 11, 2026 | 39557776Z | ACTIVE | CLASS - 2 | 3307.4.7 OBS. CONSTR. WORK IN PROGRESS ADJACENT TO SWS AT EXP. 1. WORK ZONE LOCATED WITHIN SIDEWALK BENEATH SHED W/O ... | $2,500 | $2,500 | Oct 15, 2026 |
| Aug 11, 2026 | 39557775R | ACTIVE | CLASS - 1 | 3314.4.3.1.1 OBS. PARAPET CLAMPS IN USE AT NEIGHBORING ROOF BETWEEN EXP. 1 & 4 AS RIGGING SUPPORT. UPON REQUEST, COMP... | $5,000 | $5,000 | Oct 15, 2026 |
| Jun 30, 2026 | 39556028Z | ACTIVE | CLASS - 1 | 3314.4.5.4 OBSERVED WORKER LUIS A. MOROCHO PERFORMING FACADE WORK FROM A SUSPENDED SCAFFOLD WITHOUT EVIDENCE OF COMPL... | $5,000 | $5,000 | Sep 10, 2026 |
| Jun 30, 2026 | 39556027R | ACTIVE | CLASS - 1 | 3301.7 OBSERVED ACTIVE CONSTRUCTION AT A 25-STORY ALTERATION PROJECT WITH WORK IN PROGRESS ON THE 10TH AND 22ND-25TH ... | $5,000 | $5,000 | Sep 10, 2026 |
| Jun 30, 2026 | 39556029K | ACTIVE | CLASS - 2 | OBSERVED AT EXPOSURE 3 THAT THE REQUIRED CONTROLLED ACCESS ZONE (CAZ), AS INDICATED ON THE APPROVED SITE SAFETY PLAN ... | $1,250 | $1,250 | Sep 10, 2026 |
| Jun 30, 2026 | 39556031J | ACTIVE | CLASS - 1 | 3307.6.5.1 OBS @EXPOSURE 3 OVERHEAD PROTECTION WORK AREA INCOMPLETE& NOT MAINTAINED IN SAFE CONDITION JUNIOR BEAMS NO... | $5,000 | $5,000 | Sep 10, 2026 |
| Jun 30, 2026 | 39556030H | ACTIVE | CLASS - 1 | OBSERVED AT EXPOSURES,2, 3 AND 4 INADEQUATE HOUSEKEEPING CONSISTING OF PLYWOOD, STYROFOAM, GARBAGE BAGS NOT PLACED IN... | $2,500 | $2,500 | Sep 10, 2026 |
| Apr 30, 2026 | 39553807Y | RESOLVE | CLASS - 2 | SIDEWALK SHED NON-CONFORMING TO APPROVED CONSTRUCTION DOCUMENTS: ENTIRE BAY MISSING; POSTS MISALIGNED/UNEVEN; HEADER ... | $1,250 | $1,250 | Sep 10, 2026 |
| Apr 30, 2026 | 39553798L | RESOLVE | CLASS - 1 | MIS VIO 3314.10 THROUGH 3314.10.14 OBSERVED RIGGING UTILIZING ROPES AND CABLES TIED WITH KNOTS/SPLICES IN LIEU OF PRO... | $5,000 | $5,000 | Sep 10, 2026 |
| Apr 30, 2026 | 39553797J | RESOLVE | CLASS - 1 | INADEQUATE HOUSEKEEPING OBSERVED AT EXPOS. 1,2, 3, AND 4. DEBRIS, LOOSE MATERIALS, AND EQUIPMENT SCATTERED ACROSS WAL... | $2,500 | $2,500 | Sep 10, 2026 |
| Feb 6, 2026 | 39550012R | RESOLVE | CLASS - 2 | OBSERVED SIDEWALK SHED @ EXP#1 WITH STEEL BEAMS, CONCRETE MIXER & MATERIALS STORED ON TOP. BC 3307.6.4.2.2 STATES MAT... | $2,400 | $2,400 | Apr 16, 2026 |
| Oct 29, 2025 | 39546438M | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF A 26-STORY BUILDING,I OBSERVED SIDEWALK SHED ERECTED EXP#1 DURING MY INSPECTION I NOTICED SI... | $1,250 | $1,250 | Jul 23, 2026 |
| Oct 29, 2025 | 39546439Y | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF A 26-STORY RESIDENTIAL BUILDING,I OBSERVED OUTRIGGER SUSPENDED SCAFFOLDS INSTALL AT EXP#1 UP... | $2,500 | $2,500 | Jul 23, 2026 |
| Sep 4, 2025 | 39544428J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTON I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE # 1 WITHOUT SIGNS OR PROJECT INFORMATION PANEL ON... | $3,125 | $3,125 | Sep 11, 2026 |
| Mar 13, 2025 | 35689894Z | RESOLVE | CLASS - 2 | 27-MISC, 28-MISC, BC-MISC. UNSECURED DEBRIS NETTING ON SUPPORTED SCAFFOLDING. AT TIME OF INSPECTION IT WAS OBSERVED A... | $625 | $625 | Mar 19, 2026 |
| Jan 14, 2025 | 39135431N | RESOLVE | CLASS - 2 | FLEXIBLE SIGNS THAT READ F & A DISCOUNTS, THAT APPROX (2) 15 SQ FT AND 30 SQ FT ARE ATTACHED TO PARAPET. SIGNS ARE UN... | $2,500 | $0 | Apr 17, 2025 |
| May 13, 2024 | 39528565X | RESOLVE | CLASS - 1 | A 25 STORY FACADE ALTERATION, ON MAIN ROOF EXPOSURE 3 I OBSERVED LOOSE, UNSECURE CABLES LOOPED AROUND PRAPET CLAMPS &... | $0 | $0 | Dec 11, 2025 |
| May 13, 2024 | 39528566H | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION OF 25 STORY FACADE ALTERATION, I REQUESTED FROM QSP EMITA EGBES & RIGGING FOREMAN, ARIF HUS... | $0 | $0 | May 8, 2025 |
| May 13, 2024 | 39528568L | RESOLVE | CLASS - 2 | I OBSERVED 2 WORKERS ONSITE ON MAIN ROOF. WITH REQUEST FOR TRAINING CONNECT SST CARD FROM WORKER, JUAN ANTONIO GALLEG... | $2,500 | $2,500 | Dec 11, 2025 |
| May 13, 2024 | 39528567J | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION OF 25 STORY FACADE ALTERATION, I REQUESTED FROM QSP EMITA EGBES , 6 MONTH PERIODIC INSPECTI... | $1,250 | $1,250 | Dec 11, 2025 |
| Aug 21, 2023 | 39520846X | ACTIVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT THERE WAS NO DOB LICENSED RIGGER FOREMAN ON SITE WHILE A SUSPENDED SCAFFOL... | $625 | $625 | Oct 26, 2023 |
| Aug 21, 2023 | 39520848J | ACTIVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT TIE-BACK LINES WERE CONNECTED TO ANGLE PLATES SECURED TO THE FLOOR OF THE ... | $1,250 | $1,250 | Oct 26, 2023 |
| Aug 21, 2023 | 39520849L | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT THE TIE-BACK LINE AND THE COUNTERWEIGHT LINES WERE CONNECTED TOGETHER CONT... | $0 | $0 | Mar 7, 2024 |
| Aug 21, 2023 | 39520847H | RESOLVE | CLASS - 2 | AT THE TIME OF INSPECTION, I OBSERVED THAT WIRES AROUND THE BULKHEAD EDGES WERE NOT PROTECTED FROM CHAFING AND CUTS; ... | $0 | $0 | Mar 7, 2024 |
| Feb 24, 2023 | 35662283J | ACTIVE | CLASS - 2 | NOTE:OBSERVED 23 STORY BUILDING WITH SIDEWALK SHED AT EXP #1 DETERIORATED MUDSILLS 1 STEEL BEAM BENT APROX 2 INCHES C... | $2,400 | $1,064 | May 4, 2023 |
| Feb 6, 2023 | 39512823N | ACTIVE | CLASS - 2 | UPON REACHING THE SIDEWALK SHED DECK, I OBSERVED MASONRY DEBRIS APPROX. 10 FT X 10FT X 3FT HIGH STORED ON SHED, I ALS... | $2,400 | $2,400 | Feb 8, 2024 |
| Feb 6, 2023 | 39512822L | ACTIVE | CLASS - 1 | OBSERVED WORKER ON ROOF WITH NO / MISSING GUARDRAILS, OBSERVED PARAPET REMOVED AT EXPOSURE # 3 WITH NETTING PLACED AC... | $5,000 | $5,000 | Feb 8, 2024 |
| Apr 27, 2022 | 35654189N | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN/DISPLAY ONSITE DOCUMENTS REQUIRED BY BC CHAPTER 33NOTE AT THE TIME OF MY INSPECTION AT A 25 STORY... | $2,500 | $2,500 | Oct 27, 2022 |
| Apr 27, 2022 | 35654188L | RESOLVE | CLASS - 1 | 3307.2.1 OBSTRUCTION OF STREETS OR SIDEWALKS.NO DOT PERMIT.NOTE AT THETIME OF MY INSPECTION ACTIVE CONSTRUCTION SITE,... | $2,500 | $2,500 | Oct 27, 2022 |
| Nov 15, 2021 | 35635369R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTE: AT THE TIME OF INSPECTION OBSE... | $0 | $0 | Apr 27, 2023 |
| Nov 15, 2021 | 35635368P | ACTIVE | CLASS - 1 | SEC. BC 3309.1 FAILURE TO PROVIDE ADEQUATE ROOF PROTECTION AT ADJOINING PROPERTY. NOTE: AT THE TIME OF INSPECTION,OBS... | $6,250 | $0 | Apr 27, 2023 |
| Sep 30, 2021 | 35589047J | RESOLVE | CLASS - 1 | BC3309.1 FAILURE TO PROVIDE ADEQUATE ROOF PROTECTION AT ADJOINING PROPERTY.AS NOTED:AT TIME OF INSPECTION OBSERVED AT... | $2,500 | $0 | Dec 30, 2021 |
| Sep 30, 2021 | 35589046H | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.AS NOTED:AT TIME OF INSPECTION OBSERVED ON STAIRS AT ROOF LEADING TO ... | $312 | $0 | Dec 30, 2021 |
| Sep 30, 2021 | 35589048L | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS.AS NOTED:AT TIME OF INSPECTION OBSE... | $0 | $0 | Dec 30, 2021 |
| Sep 22, 2021 | 35580374X | RESOLVE | CLASS - 1 | WORK DOESNT CONFORM TO APPROVED PLANS OR CONST DOCS&APPROVED AMENDMENTS CD5,NOTE:ATOI ON ALT2 JOB IN PROGRESS SUSPEND... | $2,500 | $2,500 | Dec 23, 2021 |
| Aug 3, 2021 | 35589259L | RESOLVE | CLASS - 2 | DOCS TO BE KEPT ONSITE ATOI ON ACTIVE JOBSITE,OBSERVED SUSPENDED SCFS INSTALLED@EXP2&4.SUSPENDED SCF PLATFORMS EQUIPP... | $625 | $625 | Mar 3, 2022 |
| Aug 3, 2021 | 35589258J | RESOLVE | CLASS - 2 | TEMP CONST EQUIPMENT ONSITE-EXPIRED PERMIT (CD5) FOR SUSPENDED SCF.ATOI ON ACTIVE JOBSITE,OBSERVED SUSPENDED SCFS INS... | $0 | $0 | Oct 21, 2021 |
| Aug 3, 2021 | 35589265H | RESOLVE | CLASS - 2 | BC3307.6.5.7 SWS INSTALLATION INSP OBSERVED SWS INSTALLED@EXP1&3 UNDERPERMIT140614823-SH EXPIRES8/2/22 UPON REQUEST F... | $0 | $0 | Oct 21, 2021 |
| Aug 3, 2021 | 35589266J | RESOLVE | CLASS - 2 | INADEQUATE SWS HOUSEKEEPING ATOI ON ACTIVE JOBSITE OBSERVED EXCESSIVE DEBRIS ON SWS DECK CREATING TRIP&FALL HAZARD TO... | $625 | $625 | Aug 25, 2022 |
| Aug 3, 2021 | 35589263Y | RESOLVE | CLASS - 1 | BC3314.8.2 FAILURE TO MAINTAIN SUPPORTED SCF DEBRIS/SAFETY NETTING.ATOI ON ACTIVE JOBSITE,OBSERVED PIPE SCF APPROX50'... | $2,500 | $2,500 | Mar 3, 2022 |
| Aug 3, 2021 | 35589261K | RESOLVE | CLASS - 1 | PERMIT HOLDER FAILED TO ENSURE WORKERS REC SSO OR REFRESHER ATOI ON ACTIVE JOBSITE,OBSERVED SUSPENDED SCF INSTALLED@E... | $5,000 | $5,000 | Mar 3, 2022 |
| Aug 3, 2021 | 35589260Z | RESOLVE | CLASS - 1 | PERMIT HOLDER FAILED TO ENSURE WORKERS ATTEND PRESHIFT SAFETY MEETING PRIOR TO COMMENCEMENT OF WORK ATOI ON ACTIVE JO... | $5,000 | $5,000 | Mar 3, 2022 |
| Aug 3, 2021 | 35589264X | RESOLVE | CLASS - 2 | BC3314.3.4 LOADS IMPOSED OBSERVED PIPE SCF APPROX50'H ERECTED ON TOP OF SWS@EXP1&4@REAR.UPON REQUEST FOR LETTER OF LO... | $0 | $0 | Oct 21, 2021 |
| Aug 3, 2021 | 35589262M | RESOLVE | CLASS - 2 | WORK DOESNT CONFORM TO APPROVED CONST DOCS &/OR APPROVED AMENDMENTS.ATOI ON ACTIVE JOBSITE,OBSERVED PIP SCF APPROX50'... | $0 | $0 | Oct 21, 2021 |
| Jun 3, 2020 | 37019171P | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTED AMENDED CYCLE 7B & 8B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL... | $0 | $0 | Sep 10, 2020 |