Skip to content

ECB violations

424 East 83 Street, Manhattan • Block 01562 • Lot 0034

25 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 21, 2014 35091274L RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER NOTED: @ APT #1W IN THE FRONT BEDRM AN APPX 10' X 8' SECTION CEILIN... $2,500 $0 Jun 5, 2014
Dec 10, 2012 32072966J RESOLVE CLASS - 3 B354,15,16,50A,50B,50C,50D,50E,50F,50G. 50A-SEAL ALL HOLES IN BOILER ROOM;50B-VALVE REQUIRED ON TOP OF OIL TANK ON SU... $100 $0 Mar 14, 2013
Nov 20, 2012 32072717Z RESOLVE CLASS - 1 B154,50A - 50A-DEFECTIVE OIL BURNER. $250 $0 Apr 18, 2013
Jun 30, 2011 34915433M RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. DEFECTS NOTED: AT TIME OF INSPECTION BOXES AND A TOILET ARE STORED I... $800 $0 Aug 19, 2011
Jun 30, 2011 34915432K RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG WALLS OR APPURTNENANCES DEFECTS NOTED: AT TIME OF INSPECTION THERE IS CRACKED/SPALLING BROWN... $500 $0 Aug 18, 2011
Nov 5, 2008 32060913H RESOLVE CLASS - 3 B354,15,16,40,50A,50B,50C. 50A FRESH AIR TO BOILER ROOM MUST HAVE SCREEN TO PROTECT FIRE DAMPER (FUSIBLE LINK) 50B SO... $250 -$250 Dec 18, 2008
Mar 6, 2008 34618804L RESOLVE Non-Hazardous SEC.27-777 FAILURE TO TERMINATE EXHAUST VENT AS PER CODE AND REFERENCE STANDARD NOTED EXHAUST VENT FROM BOILER ROOM T... $2,500 $0 Apr 24, 2008
Nov 13, 2007 32052658J RESOLVE Non-Hazardous B4A,39,50A,B,C. 50A. NO THERMOSTATIC MIXING VALVE. 50B. FLUE PIPE IS NOT DOUBLE WALL WHERE IT ENTERS THE ALLEYWAY & C... $2,500 $0 Jan 10, 2008
May 2, 2007 32050498K RESOLVE Non-Hazardous B4A,50,50A,50B,50C,50D.50-MISSING SHUT OFF VALVE AT OIL TANK.50A-ANTISYPHON VALVE AT OIL TANK MOUNTED WRONG.50B-NO AI... $2,500 $0 Jun 21, 2007
Sep 25, 2006 32051429L RESOLVE Hazardous 3B/ 50B/ 50D/ 50F/ 50A/ 50C/ 50E/ 50A DRAFT DAMPER DEFECTIVE - DAMPER NOT FOR USE ON OIL- (TOO SHORT ALSO) 3B- HAZ - ... $2,500 $0 Jun 28, 2007
May 11, 2006 34518238H RESOLVE Non-Hazardous FAILURE TO MAINTAIN. 1)AT FRONT OF PREMISES. STOP HAS CRACKS & MISSINGPART AT JOINT WITH BLDG STONE DELAMINATED & CRA... $2,500 $0 Apr 26, 2007
Apr 10, 2006 32049572L ACTIVE Hazardous B4B/41/50/50A/50B/50C/50D. 50- OIL LEAKING UNDER OIL BURNER & BOILER. 50A- INADEQUATE FRESH AIR TO ENCLOSED BOILER RM... $2,500 $0 Apr 26, 2007
Sep 14, 2005 32048667J RESOLVE Non-Hazardous 50A/50B/50C. HB SMITH C.L. BOILER LP STEAM OIL FIRED. 50A-EXCESSIVE AMBIENT TEMPERATURE IN THE BOILER ROOM. FIXED FRE... $2,500 $0 Apr 26, 2007
May 10, 2005 32047926K RESOLVE Non-Hazardous B4A/16/40/50/50A/50-HOLES IN BOILER ROOM WALL AND CEILING 50A-BOILER CLEANOUT PLATES BOLTS AND GASKETS DEFECTIVE # 1 ... $2,500 $0 Apr 26, 2007
Apr 7, 2005 32047501P ACTIVE Hazardous 3B/50/51 50-HAZARDOUS EXTREME PULSATION FROM THE BOILER 3B-HAZARDOUS SMOKING. $2,500 $0 Apr 26, 2007
Jul 19, 2004 32045731L RESOLVE Non-Hazardous 32A- WIRING AND SWITCHES NOT SECURED IN ELETRICAL BOXES AND CABLE, OR CONDUIT. $800 $0 Jan 6, 2005
Apr 15, 2004 34426479K ACTIVE Non-Hazardous PLUMBING WORK WITHOUT A PERMIT-HAZARDOUS.LOCATION-BASEMENT.INSTALLED GAS FIRED HOT WATER HEATER AND STORAGE TANK.OPEN... $250 $0 Jun 3, 2004
Apr 15, 2004 34426480H ACTIVE Non-Hazardous FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.LOCATION:BASEMENT.UTILIZING GAS FOR GAS FIRED HOT WATER HEATER ... $400 $0 Jun 3, 2004
Apr 3, 2004 34432027K RESOLVE Hazardous FAILURE TO MAINTAIN BLDG.NOTED:AT STREET METAL STAIR FROM CELLAR TO STREET TOP STEP DISLODGED CREATING HAZARDOUS COND... $800 $0 Aug 19, 2004
Mar 15, 2004 32044233Y RESOLVE Non-Hazardous B4A,16,24A,32A,40,44A,48A,50A,50B,50C,50E,50F. 50A-DABRIS IN BOILER ROOM 50B-BOILER FEED PIPE IS NOT PIPED INTO STEAM... $350 $0 Sep 9, 2004
Mar 15, 2004 32044234X RESOLVE Non-Hazardous B4B,4A,16,22C,24A,32A,36,50A,50B,50C.50A-PRESSURE AND TEMP SAFETY FROMSTORAGE TANK.50B-BOILER SAFETY VALVE NOT PIPED ... $800 $0 Sep 9, 2004
Mar 10, 2004 34415874R RESOLVE Hazardous FAILURE TO MAINTAIN BLDG: METAL STAIR CASE LEADING TO CELLAR PARTIALLY COLLAPSED AND GUARDRAIL AT GROUND LEVEL MISSIN... $800 $0 Oct 7, 2004
Jul 10, 2002 34330944K RESOLVE Non-Hazardous FAILURE TO MAINTAIN NOTE EXCESSIVE DEBRIS THROUGHOUT CELLAR AREA BOXESWOOD HOUSE APPLIANCES SINKS REFIGERATORS ETC RE... $180 $0 Aug 29, 2002
May 17, 2002 34316151J RESOLVE Non-Hazardous PLUMBING WORK WITHOUT A PERMIT ROUGHING NEW PLUMBING 3,4,5,FLOOR REMEDY OBTAIN A PERMIT IF FEASIBLE OR RESTORE TO PRI... $800 $0 Jul 11, 2002
Nov 4, 1999 34227781J RESOLVE Non-Hazardous WORK WITHOUT A PERMIT WORK NOTED: INTERIOR REHABILITATION TO APTS, BATHROOMS, KITCHEN AND LIVING ROOM FLOOR AND CEILI... $0 $0 Dec 23, 1999