| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 29, 2026 | 39190421L | ACTIVE | CLASS - 2 | CLASS 2 ITEMS: CLEAN ENTIRE PIT AREA. CITE: ASME A17.1 8.6.4.1. UPDATED CATEGORY 1 TEST TAG, CATEGORY 5 TEST TAG, AND... | $625 | $0 | Aug 6, 2026 |
| Dec 19, 2025 | 39171034H | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN ELEVATOR IN CODE COMPLIANT MANNER. SERVICE ELEVATOR AS PER BC3001.2 &27-987. UPON INSPECTION, THE... | $6,250 | $6,250 | Mar 26, 2026 |
| Jul 23, 2024 | 39119690H | RESOLVE | CLASS - 1 | CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR. CLASS 2 ITEMS: REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NE... | $3,125 | $3,125 | Aug 26, 2025 |
| Sep 14, 2023 | 39094812Z | RESOLVE | CLASS - 2 | VF. PIT HAVE WATER CLEAN. PIT LIGHT DEFECTIVE REPAIR. | $312 | $0 | Jan 4, 2024 |
| Aug 30, 2023 | 39093732Y | ACTIVE | CLASS - 1 | CLASS 1 97/X/17 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB. | $1,250 | $1,250 | Nov 9, 2023 |
| Jan 4, 2023 | 39076928L | ACTIVE | CLASS - 1 | CLASS 1... R.T.S. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE CREATING A HAZARDOUS CONTION PER 1RCNY 11... | $1,250 | $0 | Sep 7, 2023 |
| Aug 3, 2022 | 39067239L | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Jan 5, 2023 |
| May 18, 2022 | 39062414R | ACTIVE | CLASS - 1 | DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMANS SERVICE PRESENT IN CONTROLLER. INSTALL FIREMANS SERVICE SO DLM I... | $1,250 | $0 | Jun 27, 2023 |
| Apr 8, 2022 | 39059856R | RESOLVE | CLASS - 1 | D L M DEFECTIVE , REPAIR , RE INSPECTION REQUIRED. | $1,250 | $0 | Nov 17, 2022 |
| Feb 10, 2022 | 39055957H | ACTIVE | CLASS - 1 | DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMANS' SERVICE PRESENT IN THE ELEVATOR CONTROLLER. INSTALL FIREMANS' S... | $1,250 | $0 | Aug 4, 2022 |
| Jul 14, 2021 | 39044933J | RESOLVE | CLASS - 2 | CLASS 2 VIOLATION ISSUED NO SERVICE TO BASEMENT REMEDY; REPAIR DEVICE SO THAT IT STOPS IN BASEMENT,/PIT DIRTY REMEDY;... | $625 | $0 | Mar 17, 2022 |
| Jul 7, 2021 | 39044062N | RESOLVE | CLASS - 2 | PROVIDE CODE DATA TAG. BRAKE MAINTENANCE TAG MISSING, PERFORM BRAKE MAINTENANCE AND TAG DEVICE. PROVIDE FIRE SERVICE ... | $1,563 | $0 | Mar 17, 2022 |
| May 14, 2021 | 39041175X | RESOLVE | CLASS - 2 | HOIST MACHINE BRAKE MAINTENANCE TAG MISSING PROVIDE. | $312 | $0 | Nov 18, 2021 |
| Mar 18, 2021 | 39037908M | RESOLVE | CLASS - 2 | HOIST MACHINE BRAKE MAINTENANCE TAG MISSING , PROVIDE. HOIST MACHINE OIL LEAKING CLEAN, HOIST MACHINE OIL LEAKING SEAL. | $625 | $0 | May 6, 2021 |
| Jan 20, 2021 | 39035143K | RESOLVE | CLASS - 2 | PHONE NOT WORKING, FIX PHONE | $0 | $0 | Aug 26, 2021 |
| Jan 15, 2021 | 38273929J | RESOLVE | CLASS - 1 | 97-X-17=CLASS 1 RESTORE TO SERVICE REPAIR ELEVATOR & RESHORE TO SERVICE IMMEDIATELY CALL NYC DOB ELEVATOR DIBISION FO... | $3,125 | $0 | Jul 8, 2021 |
| Jan 6, 2021 | 39034388Y | RESOLVE | CLASS - 1 | R.T.S, ELEVATOR IN BUILDING OUT OF SERVICE, UP ON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE ,REPAIR AND RE... | $1,250 | $0 | Jul 8, 2021 |
| Dec 17, 2020 | 39033596Y | RESOLVE | CLASS - 1 | DOOR ELECTRIC EYE (PHOTO SENSOR) NOT WORKING. CEASE USE, RE-INSPECTION REQUIRED. PHONE IN CAR NOT WORKING. REPAIR. CA... | $1,250 | $0 | Jun 10, 2021 |
| Aug 3, 2020 | 37020024N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #382669358N ISSUED ON 6/12/19 AND TO FILE ... | $625 | $0 | Jun 10, 2021 |
| Jun 25, 2020 | 39024516K | RESOLVE | CLASS - 1 | CAR HAVE DOOR LOCK MONITORING BUT IS NOT WORKING REPAIR OR REPLACE, CAR FLOOR TO LANDING SILL NOT LEVEL ADJUST , ONE ... | $1,280 | $0 | Aug 13, 2020 |
| Jun 10, 2020 | 39023788J | RESOLVE | CLASS - 1 | IN CAR STOP SWITCH INOPERATIVE REPAIR. CAR STOPPING OFF LEVEL-ADJUST | $1,250 | $0 | Jul 30, 2020 |
| May 22, 2020 | 39022634M | RESOLVE | CLASS - 1 | 97-X-10 UPON INSPECTION ENTIRE DEVICE FOUND TO BE INOPERATIVE, REPAIR IMMEDIATELY AND NOTIFY DEPT OF BUILDINGS FOR RE... | $3,125 | $0 | Aug 13, 2020 |
| May 1, 2020 | 39021777P | RESOLVE | CLASS - 1 | 97-X-17 ENTIRE DEVICE INOPERATIVE REPAIR AND RESTORE TO SERVICE IMMEDIATELY, RE INSPECTION REQUIRED. | $1,250 | $0 | Jun 18, 2020 |
| Jul 23, 2019 | 38270658N | RESOLVE | CLASS - 1 | CU8V1,2X10,39M7,59M7,70Z2. 8V1-CAR FLOOR TO LANDING SILL NOT LEVEL ADJUST (CAR TO LANDING SILL IS 5 INS HEIGHT ABOVE ... | $1,250 | $0 | Sep 26, 2019 |
| Jun 12, 2019 | 38269358N | RESOLVE | CLASS - 2 | 5.E.1,16.J.1,23.X.10,29.J.1,67.L.10,59.M.7,56.Y.2,56.Y.(13)=5 E 1 CAR DOOR RUBBING ADJUST 16 J 1 HOIST DOOR MISALEIGN... | $625 | $0 | Aug 15, 2019 |
| May 9, 2016 | 38242627M | RESOLVE | CLASS - 2 | 59U15,68B07,99U15,42L01. NO TAG STATING DATE OF BRAKE MAINTENANCE NO ENTRY OF DATE OF BRAKE MAINTENANCE IN LOG, NO 1 ... | $0 | $0 | Jun 23, 2016 |
| Dec 16, 2015 | 38240125N | RESOLVE | CLASS - 1 | CU-08V01, 99M07,70Z09,71X10. 08V-OFF LEVEL-TRIPPING HAZARD-CALL 212- 393-2531 TO LIFT CEASE USE. | $1,000 | $0 | Feb 4, 2016 |
| Sep 2, 2015 | 38238446L | RESOLVE | CLASS - 2 | 08V01,01X10,42D06,02X10,60B07,05B01,56Y13,57BB07,99M05,46M07,35D06,12Q07,71X10,70O02,70Z09. 05B-REDUCE CAR DOOR GAP; ... | $1,250 | $0 | Oct 22, 2015 |
| Oct 10, 2007 | 38169795N | RESOLVE | Non-Hazardous | 08V01,12L10,05L10,31H11,27H11.08V-LEVELING IS OFF.12L-CAR LIGHTING IS OUT.08L-CAR DOOR DOESN'T OPEN ALL THE WAY. | $180 | -$180 | Nov 29, 2007 |
| Jan 12, 2005 | 34455743N | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR WALL DEFECTS NEED AT ROOF LEVEL PARAPET WALL NORTH FACADE STEP CRACKS NOTED:AT EAST CENT... | $0 | $0 | Mar 3, 2005 |
| Jan 11, 2005 | 34452162L | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. NOTED: AT NORTH ELEVATION PARAPET WALL- STEP CRACK IN BRICK MASONRY FROM ... | $350 | $0 | Mar 3, 2005 |
| Apr 14, 2003 | 32041703X | RESOLVE | Non-Hazardous | 34A 48A 50A 50B 50A WATER IN BOILER PT SUMP PUMP IS NOT WORKING 50B NO SYPHON ON STEAM GAGE | $440 | $0 | Sep 25, 2003 |
| Apr 14, 2003 | 32041632H | RESOLVE | Non-Hazardous | 48A, 50A. 50A- WATER IN BOILER PIT. SUMP PUMP IS NOT WORKING. 50B- NO SYPHON ON STEAM GAGE. | $440 | $0 | May 29, 2003 |
| Apr 14, 2003 | 32041633J | RESOLVE | Non-Hazardous | 34A | $180 | $0 | May 29, 2003 |
| Jan 3, 2003 | 32041014K | RESOLVE | Non-Hazardous | B4A-32A-48A-50A-50B. 32A-WIRING ON CERLING TOP OF BOILER EXPOSED FROM ELECTRIC BOX. 50A-WATER IN BOILER PITI SUMP PUM... | $180 | $0 | Feb 20, 2003 |
| Oct 18, 2002 | 32040725M | RESOLVE | Non-Hazardous | 34A/50A/50B/50C. 50A ELECTRICAL CONTRALS MISSING COVERS- 50B ELECTRICAL SUMP PUMP OULTET- REAR OF BOILER HANGING, EXP... | $800 | $0 | Jan 23, 2003 |
| Apr 27, 1999 | 38086819P | RESOLVE | Non-Hazardous | 22D 35L 53L 50Y 56M 57O 22 STORE 35 MOTOR RM STIRS 53 LIGHTING 50 OIL LEAK E5 PROVIDE 57 CLEAN | $0 | $0 | Jun 17, 1999 |
| May 23, 1997 | 38060081M | RESOLVE | Non-Hazardous | 75 PROVIDE 5 YEAR TEST | $0 | $0 | Aug 14, 1997 |