ECB violations
Mt Sinai Hess Center For Science, Manhattan • Block 01607 • Lot 0005
14 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Oct 1, 2024 | 37030946Z | RESOLVE | CLASS - 1 | FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE OR A PE... | $0 | $0 | May 12, 2026 |
| Mar 1, 2011 | 34874963L | RESOLVE | CLASS - 2 | FAIL TO PROVIDE VERTICAL NETTING.UPON INSPECTION AS NOTED ON ACTIVE CONSTRUCTION SITE UP TO 12TH (ROOF)THE VERTICAL N... | $0 | $0 | Apr 21, 2011 |
| Feb 24, 2011 | 34874958R | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS:UPON INSPECTION AS NOTED ON ACTIVE CO... | $0 | $0 | Jul 28, 2011 |
| Nov 30, 2010 | 34875562P | RESOLVE | CLASS - 2 | FAILURE TO STORED STRENGTH TEST CYLINDER IN FIELD STORAGE CURING BOX @ SITE AS NOTED @ TIME OF INSPECTION @ AN ACTIVE... | $1,600 | $0 | Jan 20, 2011 |
| Nov 30, 2010 | 34875563R | RESOLVE | CLASS - 2 | FAILURE TO STORED STRENGTH TEST CYLINDER IN FIELD STORAGE CURING BOX @ SITE AS NOTED @ TIME OF INSPECTION @ ACTIVE CO... | $0 | $0 | Jan 20, 2011 |
| Nov 15, 2010 | 34860920Y | RESOLVE | CLASS - 2 | SEC. 3301.1.2. FAILURE TO COMPLY W/NYC FIRE CODE. NO FIRE WATCH PERSONS. AT THE TIME OF MY INSPECTION APPROX 40 WORKE... | $0 | $0 | Jan 6, 2011 |
| Aug 10, 2010 | 34860776Z | RESOLVE | CLASS - 2 | 3303.2.2 FAILURE TO HAVE AUTHORIZATION FROM APPROPRIATE AGENCY FOR USING FIRE HYDRANT. OBSERVED WATER BEEN USED FOR C... | $0 | $0 | Sep 30, 2010 |
| Jul 28, 2010 | 34860142R | RESOLVE | CLASS - 2 | SEC. 28-407.1 FAILURE TO PROVIDE NYC D.O.B. WELDERS LICENSE FOR WELDING ON STRUCTURAL MEMBER. OBSERVE A WORKER WELDIN... | $0 | $0 | Sep 16, 2010 |
| Jul 1, 2010 | 34769493L | RESOLVE | CLASS - 2 | FAILURE TO PERFORM REQUIRED RESPONSIBILITIES - UPON INSPECTIO NOTED: THE NB PERMIT #104631141 OF THIS JOB HAS BEEN EX... | $0 | $0 | Aug 26, 2010 |
| Jul 1, 2010 | 34769492J | RESOLVE | CLASS - 2 | WORK W/O A PERMIT - EXPIRED PERMIT - UPON INSPECTION, CONSTRUCTION WORK IN PROGRESS, WORKERS INSTALLING STAIRS AT THE... | $0 | $0 | Aug 26, 2010 |
| Jan 20, 2010 | 34826860M | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION NO TOE BOARDS. AS NOTED: AT TIME OF... | $1,000 | $0 | Mar 11, 2010 |
| Dec 9, 2009 | 34819281M | RESOLVE | CLASS - 1 | SEC. 3307.8.1. FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURESOR TEMPORARY CONSTRUCTION - NO TOE BOARDS. NOTE... | $1,600 | $0 | May 6, 2010 |
| Apr 20, 2000 | 38097210Z | RESOLVE | Non-Hazardous | 43B07,11R09. 43-PERFORM REQUIRED PERIODIC TESTS (PRESSURE RATED AND RELIEF ) 11-ELIMINATES TILE CONTROL OF CAR LIGHTI... | $0 | $0 | Jun 8, 2000 |
| Apr 20, 2000 | 38097211K | RESOLVE | Non-Hazardous | 43B07,11R09.43- PERFORM REQUIRED PERIODIC TESTS (PRESSURE RATED AND RELIEF ) 11-ELIMINATE THE CONTROL OF CAR AND FAN ... | $0 | $0 | Jun 8, 2000 |