ECB violations
101 East 97 Street, Manhattan • Block 01625 • Lot 0102
16 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| May 28, 2015 | 35132124Y | RESOLVE | CLASS - 2 | 3314.3.3 PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT TO 28-207.2 AND POSTED ON PREMISES.FAILURE TO PROVIDE DRA... | $0 | $0 | Jul 16, 2015 |
| May 28, 2015 | 35132123M | RESOLVE | CLASS - 1 | PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT TO 28-207.2 AND POSTED ON PREMISES.NOTIFICATION OF ADJUSTABLE SUSP... | $8,000 | $0 | Jul 16, 2015 |
| May 28, 2015 | 35132200R | RESOLVE | CLASS - 1 | 3314.4.5.4(TRAINING)FOR SUSPENDED SCAFFOLD.NOTED:@ TIME OF INSP.FOLLOWING WORKER:JOSE YAMASGUI WORKING ON SUSPENDED S... | $8,000 | $0 | Jul 16, 2015 |
| Dec 23, 2014 | 35150218Y | RESOLVE | CLASS - 2 | 3314.4.6,USE OF SUPPORTED SCAFFOLD W/O A SCAFFOLD USER CERT.NOTED:@ TIME OF INSP FOLLOWING WORKER:LUIS CAMPOS WORKING... | $400 | $0 | Feb 12, 2015 |
| Dec 23, 2014 | 35150217M | RESOLVE | CLASS - 1 | 3314.8,PARTIAL SWO ISSUED FOR SUPPORTED SCAFFOLD PURSUANT 28-207.2 & POSTED ON PREMISES.FAILED TO PROVIDE TOEBOARDS,G... | $1,600 | $0 | Feb 12, 2015 |
| Dec 23, 2014 | 35150216K | RESOLVE | CLASS - 2 | PARTIAL SWO ISSUED FOR SUPPORTED SCAFFOLD PURSUANT 28-207.2 & POSTED ON PREMISES.WORK W/O PERMIT.NOTED @ IME OF INSP ... | $0 | $0 | Feb 12, 2015 |
| Nov 6, 2013 | 35037619K | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE BLDG:SERVICE ENTRANCE,200MP SERVICE SWITCH, SUBFEEDERS,SUBPANELS, BRANCH CIR... | $1,600 | $0 | Jan 30, 2014 |
| Mar 15, 2013 | 34999758L | RESOLVE | CLASS - 2 | FAILURE TO FILE A SPECIAL INSPECTION STATEMENT OF RESPONSIBILITY PRIORTO PERMIT ISSUANCE AND PRIOR TO START OF WORK U... | $800 | $0 | Jun 13, 2013 |
| Mar 14, 2013 | 34999755X | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERAIONS: 1) C-JOISTS HAVE BEEN USED AS A TEMP... | $2,400 | $0 | Jun 13, 2013 |
| Mar 14, 2013 | 34999756H | RESOLVE | CLASS - 2 | OBSERVED RECENT SMOKING REFUSE W/I CONSTRUCTION SITE IN VIO OF NYC FIRE CODE. EVIDENCE CONSISTS ON CIGARETTE CARTON O... | $1,200 | $0 | Jun 13, 2013 |
| Mar 14, 2013 | 34999757J | RESOLVE | CLASS - 2 | FAILURE TO POST "NO SMOKING" SIGNS AT CONSTRUCTION SITE IN VIOLATIONS OF FIRE CODE. NO SMOKING SIGNS THROUGHOUT THE C... | $400 | $0 | Jun 13, 2013 |
| Mar 14, 2013 | 34999753M | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET BLDG CODE SPECIFICATION. THE ELECTRICAL WIRING FOR THE SHED IS GROSSLY INADEQUATE. INADEQ... | $2,400 | $0 | Jun 13, 2013 |
| Mar 14, 2013 | 34999754Y | RESOLVE | CLASS - 1 | SEC. 3301.2. FAILURE TO PROVIDE 3'-6" GUARD RAIL OR EQUIPMENT AROUND ALL FLR AND PERIMETER OPENINGS. GUARDRAILS ARE M... | $1,600 | $0 | Jun 13, 2013 |
| Feb 26, 2013 | 34989744L | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION. NOTED: SHED POST AT EXPOSURE #1,LEANING/OUT OF PLUMB. REMEDY: CONFORM... | $2,400 | $0 | Apr 18, 2013 |
| May 18, 2011 | 34908247N | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION - NO GUARD RAILS. 1- NO GUARDRAILS ... | $0 | $0 | May 1, 2014 |
| Feb 17, 2011 | 34879657X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER DEFECTS NOTED AT TIME OF INSP THERE IS MISSING DETERIORATED MORTA... | $0 | $0 | May 1, 2014 |