| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 14, 2024 | 39130308P | ACTIVE | CLASS - 2 | OBSERVED NON SELF CLOSING DOORS THROUGHOUT BASEMENT. INCASE OF FIRE THIS CAN BE A FIRE OR SMOKE HAZARD., REPAIR/REPLA... | $625 | $0 | Nov 21, 2024 |
| Nov 14, 2024 | 39130295P | ACTIVE | CLASS - 2 | I OBSERVED IN THE BASEMENT MAINTENANCE STORAGE AREA ENERGIZED BX CABLES EXPOSED AND NOT TERMINATED IN A JUNCTION BOX ... | $800 | $0 | Nov 21, 2024 |
| Nov 14, 2024 | 39130296R | ACTIVE | CLASS - 2 | I OBSERVED IN THE FIRST FLOOR MAINTENANCE ROOM NO GFCI PROTECTION WITHIN 6 FEET OF A SINK., INSTALL GFC1 PROTECTION; ... | $2,400 | $0 | Nov 21, 2024 |
| Nov 14, 2024 | 39130307N | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,500 | $0 | Nov 21, 2024 |
| Apr 5, 2023 | 39083144Z | ACTIVE | CLASS - 2 | I OBSERVED IN THE MAINTENANCE CLOSET THE RECEPTACLE WITHIN 6 FEET OF THE SINK NOT OF THE GFCI TYPE., INSTALL GFC1 PRO... | $2,400 | $0 | Apr 27, 2023 |
| Jan 4, 2023 | 39076969H | ACTIVE | CLASS - 2 | OBSERVED: AT CELLAR LEVEL, FRONT EXIT DOOR AND FIRST FLOOR MAIN ENTRANCE DOOR DO NOT CLOSE PROPERLY WHEN INSPECTED., ... | $625 | $0 | Jan 10, 2023 |
| Jan 4, 2023 | 39076970P | ACTIVE | CLASS - 2 | OBSERVED: CERTIFICATE OF OCCUPANCY # 107465/1995, INDICATED AT THE CELLAR LEVEL (STORAGE ROOMS AND COMPACTOR ROOM),OB... | $1,250 | $0 | Jan 10, 2023 |
| Jan 4, 2023 | 39076963R | ACTIVE | CLASS - 2 | GAS PIPING IN THE BASEMENT HAS AREAS OF RUST AND CORROSION. AS PER PC 102.3 INSTALLATIONS, BOTH EXISTING AND NEW, AND... | $625 | $0 | Jan 10, 2023 |
| Nov 5, 2021 | 35631756Z | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES AND PUBLIC... | $1,250 | $0 | Feb 17, 2022 |
| Sep 11, 2019 | 39009383K | RESOLVE | CLASS - 2 | NOTED: OBSERVED AT EXPOSURE #1 SOUTH ELEVATION, BULGING CEMENT AND AN APPROXIMATELY 1" HORIZONTAL CRACK THROUGHOUT TH... | $0 | $0 | Sep 20, 2019 |
| Mar 22, 2019 | 35383816L | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES NOTED: OBSERVED HORIZONTAL CRACKS IN THE RETAINING WALL AT EXP1... | $0 | $0 | May 30, 2019 |
| Mar 23, 2018 | 35322498X | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUIDLING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED AT FIRST FLOOR VESTIBULE NEXT TO UNIT 1-B,SPALLI... | $0 | $0 | May 31, 2018 |
| Mar 23, 2018 | 35322497Y | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTED:OBSERVED ATFRONT OF BUILDING THE RETAINING WALLS ADJACENT ... | $0 | $0 | May 31, 2018 |
| Aug 22, 2017 | 35290002J | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVED AT FRONT OF BUILDING. RETAINING WALL IS IN DIS... | $0 | $0 | Dec 21, 2017 |
| Aug 22, 2017 | 35290275P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN BSMT ANUNSERVICEABLE ELECTRICALLY POWERED GARBAGE COMP... | $2,500 | $0 | Oct 19, 2017 |
| Aug 22, 2017 | 35290276R | ACTIVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,DEVICES,MATERIALS,APPLIANCES OR WIRING IN USE. OBSERVED I... | $8,000 | $0 | Oct 19, 2017 |
| Aug 22, 2017 | 35289645P | ACTIVE | CLASS - 1 | FGC 411.1 RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT OBSERVED ON 8/22/2017 @ABOVE ADDRESS RESIDENTIAL GAS FLEX... | $0 | $0 | Dec 21, 2017 |
| Mar 27, 2017 | 35235743P | ACTIVE | CLASS - 2 | FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER RE: INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC102... | $0 | $0 | Apr 27, 2017 |
| Mar 27, 2017 | 35235744R | ACTIVE | CLASS - 1 | SEC. 401.1 GAS PIPING NOT LABELED OBSERVED ON 3-27-17 GAS PIPING NOT LABELED IN BASEMENT. REMEDY: COMPLY W/SUMMONS. | $0 | $0 | Apr 27, 2017 |
| Sep 16, 2016 | 35207828X | ACTIVE | CLASS - 2 | EXIT DOOR NOT SELF-CLOSING.NOTE: EXIT DOOR TO ROOF LEVEL NOT SELF CLOSING. RMDY: REPAIR/REPLACE DOOR. | $0 | $0 | Nov 17, 2016 |
| Sep 16, 2016 | 35207840Z | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN IN CODE-COMPLIANT MANNER. DEFECT NOTED:RETAINING WALL AT FRONT OF PREMISES HAS APPROX 2"WIDE HORI... | $0 | $0 | Nov 17, 2016 |