ECB violations
191 East 100 Street, Manhattan • Block 01628 • Lot 0030
23 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 14, 2024 | 39130741X | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HANDRAIL AT BASEMENT LEVEL DETRACTED FROM WALL. BROKE... | $1,250 | $0 | Nov 21, 2024 |
| Nov 14, 2024 | 39130250L | ACTIVE | CLASS - 2 | I OBSERVED IN THE FIRST FLOOR MAINTENANCE ROOM NO GFCI PROTECTION WITHIN 6 FEET OF A SINK., INSTALL GFC1 PROTECTION; ... | $2,400 | $0 | Nov 21, 2024 |
| Nov 14, 2024 | 39130740Y | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 ... | $2,500 | $0 | Nov 21, 2024 |
| Apr 5, 2023 | 39083146M | ACTIVE | CLASS - 2 | I OBSERVED IN THE MAINTENANCE CLOSET THE RECEPTACLE WITHIN 6 FEET OF THE SINK NOT OF THE GFCI TYPE., INSTALL GFC1 PRO... | $2,400 | $0 | Apr 27, 2023 |
| Jan 4, 2023 | 39076997P | ACTIVE | CLASS - 2 | -OBSERVED: AT CELLAR LEVEL, FRONT EXIT DOOR AND FIRST FLOOR MAIN ENTRANCE DOOR DO NOT CLOSE PROPERLY WHEN INSPECTED, ... | $625 | $0 | Jan 10, 2023 |
| Jan 4, 2023 | 39076964Z | ACTIVE | CLASS - 2 | OBSERVED GAS PIPING IN THE BASEMENT HAS AREAS OF RUST AND CORROSION. AS PER PC 102.3 INSTALLATIONS, BOTH EXISTING AND... | $625 | $0 | Jan 10, 2023 |
| Jan 4, 2023 | 39076999Z | ACTIVE | CLASS - 2 | OBSERVED: AT ROOF LEVEL, STAIRCASE EXTERIOR WALLS CRACKED NEAR EXIT DOOR., MAINTAIN EXTERIOR BUILDING WALL | $1,250 | $0 | Jan 10, 2023 |
| Jan 4, 2023 | 39076998R | ACTIVE | CLASS - 2 | OBSERVED: AT CELLAR LEVEL, STORAGE ROOMS, RETAINING WALL SHOWS DETERIORATION, PEELING PAINT, MOLD, AND LOSS MORTAR, D... | $1,250 | $0 | Jan 10, 2023 |
| Apr 15, 2022 | 39060430H | ACTIVE | CLASS - 2 | - AT FIRST FLOOR, BACK SIDE ,METAL STAIRS OF THE EVACUATION ROUTE ARE DAMAGED BY DETERIORATION AND CORROSION., REPAIR... | $625 | $0 | Apr 19, 2022 |
| Nov 5, 2021 | 35631754P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.LACK OF EMERGENCY LIGHTING FOR EXITS EXIT DISCHARGES AND PUBLIC... | $1,250 | $0 | Feb 17, 2022 |
| Sep 11, 2019 | 39009389L | RESOLVE | CLASS - 2 | NOTED: OBSERVED AT EXPOSURE #1 SOUTH ELEVATION, BULGING CEMENT AND AN APPROXIMATELY 1" HORIZONTAL CRACK THROUGHOUT TH... | $0 | $0 | Sep 20, 2019 |
| Mar 22, 2019 | 35383818P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVEDCRACKS AND BULGING CONCRETE ALONG THE LENGTH OF... | $0 | $0 | May 30, 2019 |
| Sep 28, 2018 | 35361395P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NO FIRE STOPPINGPER BC712.3;27-345. NOTED:AT CELLAR, IN SUPPLY ... | $0 | $0 | Nov 29, 2018 |
| Sep 28, 2018 | 35361394N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED:AT ROOF, COPING STONES ARE LOOSE AND MISSING IN VARIOUS ... | $0 | $0 | Nov 29, 2018 |
| Mar 23, 2018 | 35325703J | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTED:OBSERVED ATFRONT OF BUILDING THE RETAINING WALL HAVE CRACK... | $0 | $0 | May 31, 2018 |
| Aug 22, 2017 | 35290005P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED: OBSERVED AT FRONT OF BUILDING, RETAINING WALL HAS HORIZ... | $0 | $0 | Dec 21, 2017 |
| Aug 22, 2017 | 35290277Z | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED IN BSMT ANUNSERVICEABLE ELECTRICALLY POWERED GARBAGE COMP... | $2,500 | $0 | Oct 19, 2017 |
| Aug 22, 2017 | 35289647Z | ACTIVE | CLASS - 1 | FGC 411.1 RESIDENTIAL GAS FLEX USED ON COMMERCIAL EQUIPMENT.OBSERVED ON 08/22/17 @ABOVE ADDRESS RESIDENTIAL GAS FLEX ... | $0 | $0 | Dec 21, 2017 |
| Mar 27, 2017 | 35235747M | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. OBSERVED ON 3-27-17 IN BASEMENT FIRE STOP MATERIAL IS COVERING GAS... | $0 | $0 | Apr 27, 2017 |
| Mar 27, 2017 | 35235749X | ACTIVE | CLASS - 1 | SEC. 401.1 GAS PIPING NOT LABELED. ON 3-27-17 IN BASEMENT/CELLAR LEVELAT ABOVE ADDRESS GAS PIPING NOT LABELED. REMEDY... | $0 | $0 | Apr 27, 2017 |
| Mar 27, 2017 | 35235748Y | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 3-27-17IN BASEMENT/CELLAR AT ABOVE ADDRESS JIM CAPS AR... | $0 | $0 | Apr 27, 2017 |
| Sep 16, 2016 | 35208030L | ACTIVE | CLASS - 1 | MISC VIOL. OBSERVED ON 9/16/16 AT 10:20AM IN LAUNDRY ROOM RESID GAS FLEX ON COIN OP COMM GAS DRYER. PHOTOS TAKEN. RMD... | $0 | $0 | Nov 17, 2016 |
| Sep 16, 2016 | 35207842M | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN IN CODE COMPLIANT MANNER. DEFECTS NOTED:RETAINING WALL AT FRONT OF PREMISES HAS APPRX 2"WIDE HORI... | $0 | $0 | Nov 17, 2016 |