ECB violations
152-158 East 103 Street, Manhattan • Block 01630 • Lot 0041
16 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 14, 2024 | 39103488H | RESOLVE | CLASS - 1 | SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE TO CRACK ABOVE WINDOW LENTIL OF APARTMENT 5F ALONG WITH WATER DAMAGE TO SH... | $1,250 | $0 | Mar 21, 2024 |
| Feb 24, 2023 | 39080235K | RESOLVE | CLASS - 1 | I OBSERVED IN LAUNDRY ROOM IN CELLAR NEWLY INSTALLED SPRINKLER PIPING AND HEADS FOR SEVERAL COMMERCIAL GAS DRYERS AND... | $2,500 | $0 | Nov 2, 2023 |
| Feb 24, 2023 | 39080236M | ACTIVE | CLASS - 2 | I OBSERVED IN LAUNDRY ROOM IN CELLAR NEWLY INSTALLED SPRINKLER PIPING AND HEADS FOR SEVERAL COMMERCIAL GAS DRYERS AND... | $1,250 | $0 | Nov 2, 2023 |
| Feb 24, 2023 | 39080234Z | RESOLVE | CLASS - 1 | I OBSERVED IN LAUNDRY ROOM IN CELLAR AREA SEVERAL COMMERCIAL GAS DRYERS WITH ALL NECESSARY PIPING; HOWEVER C OF O STA... | $1,250 | $0 | Nov 2, 2023 |
| Jun 9, 2014 | 38231662Y | RESOLVE | CLASS - 2 | 57R05,70Z09,70O02,71M07,WORK W/O PERMIT,57-AC MOTOR WAS INSTALLED W/O PERMIT BEING OBTAINED & APPLICATION BEING FILED... | $4,000 | $0 | Jul 24, 2014 |
| Mar 22, 2013 | 38226279P | RESOLVE | CLASS - 2 | B251:52Q03,70O02,71L10,70AM07,15I10,11I10.52:FRONT CABLE GUARD MISSING.70:CLEAN PIT.71:FIX PIT LIGHT.70A:COVER SUMP P... | $530 | -$530 | May 9, 2013 |
| Oct 26, 2011 | 38218756Z | RESOLVE | CLASS - 2 | 02X10,01B10,77B11,03B10,70Z09,70O02,16E01. 01X10-ALARM DOES NOT WORK WITH STOP SW. 77B11-REPLACE TOE GUARD TO 21" AS ... | $250 | $0 | Dec 15, 2011 |
| Mar 2, 2010 | 38209700P | RESOLVE | CLASS - 2 | 61/L/10,98/BB/05,68/M/07,69/M/07,67/X/10,71/X/10,70/B/07,61-L-REPAIR MAINLINE BOX WHEN IN THE OFF POSITION,POWER REMA... | $500 | $0 | Apr 22, 2010 |
| Dec 23, 2009 | 38206314N | RESOLVE | CLASS - 2 | 99BB05 46Q07 56E10 46O02 46O02 61P09 41M07 03O02 17M07 70Q07 67L10 34O02 74O02 46-PROVIDE COVER FOR GOVERNOR ELECTRIC... | $500 | $0 | Feb 11, 2010 |
| Jun 26, 2009 | 32065996P | ACTIVE | CLASS - 3 | B354151650A50B50C. 50A CHECK VALVE REQUIRED TO BE BETWEEN BACK FLOW PREVENTOR AND PRESSURE REDUCING VALVE 50B RELIEF ... | $200 | $0 | Apr 22, 2010 |
| Apr 17, 2009 | 38202413K | RESOLVE | CLASS - 2 | 98BB5.17H07.67L10.17H7 HOISTWAY DOOR GIBS ARE WORN PROVIDE WERE NEEDED 67L10 EMERGENCY INTERCOM IN ELEVATOR NOT WORKI... | $500 | $0 | Jun 11, 2009 |
| Feb 23, 2005 | 38151118K | RESOLVE | Non-Hazardous | 85BB05/51H11/43H10. | $2,500 | $0 | Jul 28, 2005 |
| Jan 4, 2000 | 38093313N | RESOLVE | Non-Hazardous | 15L11,16H12,09H12,22D06,35O02,37G1214M07. 15L11- NOT SELF CLOSING 2,3 AND 4 FLOORS 16H12= 1ST FLOOR 37G12=1, AND 10 A... | $0 | $0 | Feb 24, 2000 |
| Mar 25, 1999 | 38085843K | RESOLVE | Non-Hazardous | 35Z11,50Y11,40A11,50O2. -40A11 REMOVE KNOCKING FROM GOVERNOR | $180 | $0 | Aug 12, 1999 |
| Sep 2, 1998 | 38079283K | RESOLVE | Non-Hazardous | 01X.#01X11 CEASE USE TILL REPAIR IS MADE CALL 312-8732 BEFORE RESTORING TO SERVICE. | $500 | $0 | Oct 22, 1998 |
| Oct 11, 1991 | 38019082J | RESOLVE | Non-Hazardous | 74L; 74.REPAIR, ELECTRIC EYE FOR INNER DOOR. | $1,000 | $0 | Jan 16, 1992 |