Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 13, 2026 | 39200417P | ACTIVE | CLASS - 2 | CLASS2 ITEM: RTS FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, SERVICE ELEVATOR EQUIPMENT AS PER CODE BC3001... | $625 | $625 | Oct 22, 2026 |
| Jun 8, 2026 | 39194925N | ACTIVE | CLASS - 1 | CLASS 1 RTS:LURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987.... | $1,250 | $0 | Jul 9, 2026 |
| Jun 8, 2026 | 39194924L | ACTIVE | CLASS - 1 | CLASS 1 RTS:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-9... | $1,250 | $0 | Jul 9, 2026 |
| Jun 2, 2026 | 39190910M | ACTIVE | CLASS - 2 | RTS CLASS 2: UPON INSPECTION, THE ELEVATOR WAS FOUND STALLED AT THE 10TH FLOOR WITH THE HOISTWAY DOORS CLOSED AND FAI... | $625 | $0 | Jul 9, 2026 |
| Jun 2, 2026 | 39190911Y | ACTIVE | CLASS - 1 | CEASE USE ITEM: ELEVATOR DOOR ZONE RESTRICTOR INOPERATIVE. AS PER (ASME A17.1-2013 / NYC APPENDIX K 2.26.1.40.1 AND 8... | $1,250 | $0 | Jul 9, 2026 |
| Oct 14, 2025 | 39163538L | ACTIVE | CLASS - 3 | AERCO BOILER HAS THE #1 HEATING CIRCULATOR LEAKING WATER+FLANGES LEAKING WATER@DOMESTIC HW HEAT EXCHANGER #2;CORRECT ... | $500 | $0 | Oct 20, 2025 |
| Feb 20, 2018 | 38261359Z | RESOLVE | CLASS - 1 | CU05A10,02X10,68B07. 05A10- CEASE USE ITEM. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH DISABLED ND RENDERED INOPERAT... | $0 | $0 | May 3, 2018 |
| Jan 14, 2014 | 35078047P | RESOLVE | CLASS - 1 | PARTIAL *SWO* FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES:NOTE:NO GUARDRAILS NOTICED @TIME OF INSPECTION.... | $2,400 | $0 | Mar 6, 2014 |
| Jan 14, 2014 | 35087252Z | RESOLVE | CLASS - 2 | 28-301.1 OWNERS RESPONSIBILITY ALL BLDG, ALL PARTS & ALL OTHER STRUCTURES SHALL BE MAINTAINED IN A SAFE CONDITION.NOT... | $0 | $0 | Mar 6, 2014 |
| Jan 14, 2014 | 35087250P | RESOLVE | CLASS - 1 | 3303.1.2 SERVICE LINE AND CONDUIT CONSTITUTE TRIPPING HAZARDS.NOTE:@TIME OF INSPECTION ELECTRICAL CORDS ON FLOORS THR... | $400 | $0 | Apr 3, 2014 |
| Jan 14, 2014 | 35087251R | RESOLVE | CLASS - 1 | FAIL TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES-NO HANDRAILS/NOTE:@TIME OF INSPECTION NOTICED HANDRAILS MISSING ... | $1,000 | $0 | Apr 3, 2014 |
| Jan 14, 2014 | 35078049Z | RESOLVE | CLASS - 1 | FULL *SWO* FAILURE TO SAFEGUARD ALL PERSONS AND PROP AFFECTED BY CONSTRUCTION OPS.@TIME OF INSPECTION INCIDENT FORKLI... | $2,400 | $0 | Apr 3, 2014 |
| Jan 14, 2014 | 35078048R | RESOLVE | CLASS - 1 | PARTIAL *SWO* FAIL TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQ.NOTE:@TIME OF INSPECTION INADEQUATE HOUSEKEEPING... | $2,400 | $0 | Mar 6, 2014 |
| Jul 5, 2013 | 35018868H | RESOLVE | CLASS - 1 | 3303.15.2 FAILURE TO PROVIDE COLLECTION AND CONTAINMENT OF CONCRETE WASHOUT.AT TIME OF INSPECTION OBSERVED PILE OF CO... | $1,600 | $0 | Sep 26, 2013 |
| Jun 18, 2013 | 35018296L | RESOLVE | CLASS - 1 | SEC. 3301.2 HOLES/OPENINGS NOT COVERED,AT TIME OF INSPECTION OBSERVED OPEN PENETRATIONS ON 3RD FL WORKING DECK. HOLES... | $1,600 | $0 | Aug 8, 2013 |
| Jun 18, 2013 | 35018297N | RESOLVE | CLASS - 1 | SEC. 3307.6.4.5 SIDEWALK SHED DOES NOT MEET CODE SPECS. AT TIME OF INSPECTION SIDEWALK SHED CONSTRUCTED ON 2ND AVE,HA... | $1,600 | $0 | Aug 8, 2013 |
| Jun 18, 2013 | 35018299R | RESOLVE | CLASS - 1 | HOUSEKEEPING/FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING OBSERVED STANDING WATER THROUGHOUT 1ST FL APP 2" OBSERVED DEBR... | $400 | $0 | Aug 8, 2013 |
| Jun 18, 2013 | 35018850J | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATION/AT TIME OF INSPECTION OBSERVED REBAR A... | $2,400 | $0 | Aug 8, 2013 |
| Jun 18, 2013 | 35018851L | RESOLVE | CLASS - 1 | SEC. 3307.6.2 AREAS TO BE PROTECTED. DURING TIME OF INSPECTION NO OVERHEAD PROTECTION OVER ENTERANCES OF JOBSITE,LOCA... | $1,600 | $0 | Aug 8, 2013 |
| Jun 18, 2013 | 35018295J | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE GUARDRAILS. AT TIME OF INSPECTION OBSERVED NO GUARDRAILS AT WORKING 3RD FL DECK,NO PERIMETER GUARD... | $1,200 | $0 | Aug 8, 2013 |
| Jun 18, 2013 | 35018298P | RESOLVE | CLASS - 1 | SEC. 3301.1.2 SERVICE LINE CONDUIT & POWER CORDS CONSTITUTE A TRIPPINGHAZARD. AT TIME OF INSPECTION APPROX 10 TO 15 P... | $1,600 | $0 | Aug 8, 2013 |
| Jun 12, 2013 | 35018307H | RESOLVE | CLASS - 1 | SEC. 3303.11. REQUIRED MEANS OF EGRESS SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION OR DEMO. NOTED: ONE EGRES... | $1,600 | $0 | Aug 1, 2013 |
| Sep 29, 2008 | 34698872X | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN INTERIOR.AS PER INSPECTION & P.E.REPORT.2FL SLAB CRACKED IN SEVERAL PLACES,METAL BEAM ARE DAMAGED... | $0 | $0 | Apr 16, 2009 |
| Sep 17, 2008 | 34698856X | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR.CONCRETE SLAB FLOOR IS SAGGING IN SEVERALLOCATIONS ON 2FL & CEILING HAS SEVERAL HOLES IN... | $0 | $0 | Apr 16, 2009 |
| Mar 7, 2008 | 34618901N | ACTIVE | Hazardous | FAILURE TO MAINTAIN BUILDING DEFECT NOTED BLDG HAVING AT 2ND SL NORTH SIDE CEILING SEVERAL HOLES WITH RUSTING HANGING... | $800 | $0 | Apr 24, 2008 |
| Apr 9, 2004 | 34460477X | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $0 | $0 | Sep 16, 2004 |