Skip to content

ECB violations

317-323 East 104 Street, Manhattan • Block 01676 • Lot 0011

49 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Nov 17, 2025 39167187R RESOLVE CLASS - 1 CLASS 1 CEASE USE ITEMS: 1) DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY... $1,250 $1,250 Jan 22, 2026
Nov 17, 2025 39167202X ACTIVE CLASS - 2 OBSERVED IN LAUNDRY ROOMS ON FLOORS 2,3,4,AND 5 COMMERCIAL ELECTRICAL DRYERS WITH NO SPRINKLER COVERAGE ON SECOND FLO... $1,250 $1,250 Sep 22, 2026
Jan 22, 2025 39136220H RESOLVE CLASS - 2 CLASS 2 ITEMS: IN-CAR EMERGENCY LIGHTING INOPERATIVE. PROVIDE AN UPDATED MAINTENANCE LOG. PROVIDE A MAINTENANCE PROGRAM. $0 $0 Apr 3, 2025
Jan 22, 2025 39136221J RESOLVE CLASS - 1 CEASE USE ITEM: FR-1 2 AMP FUSE BYPASSED IN CONTROLLER. . REMEDY: RESTORE TO SERVICE IMMEDIATELY AND CALL THE DOB ELE... $1,250 $0 Apr 3, 2025
Jan 22, 2025 39136147K ACTIVE CLASS - 2 FOUND HYDROTHERM BOILER #2 UNIT 14 GAS FIRED BOILER NOT OPERABLE, ALSO CORRODED FLANGES ON DHW CIRCULATOR. $655 $0 Apr 3, 2025
Sep 27, 2022 39070917Z RESOLVE CLASS - 1 DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLED(CU). RUSTED CABLES ON THE MACHINE CLEAN AND MONITOR CONDITION... $1,280 $0 Nov 17, 2022
Sep 27, 2022 39070895R RESOLVE CLASS - 2 I OBSERVED IN THE BASEMENT SEWER/LAUNDRY ROOM FLEXIBLE RACEWAY SUPPLYING POWER TO THE WASHING EQUIPMENT WITH NO EQUIP... $2,430 $0 Nov 17, 2022
Sep 27, 2022 39070916R RESOLVE CLASS - 2 GRINGING NOISE COMING FROM THE HOISTWAY. NO SLACK CABLE SWITCH FOR THE HOIST ROPES. $655 $0 Nov 17, 2022
Sep 27, 2022 39070889K RESOLVE CLASS - 2 OBSERVED AT FIRST FLOOR & CELLAR LEVEL, UTILITY ROOMS/ELEVATOR ROOM, SEVERAL OPENING, DUE, PIPE PENETRATION THROUGH T... $0 $0 Nov 17, 2022
Sep 27, 2022 39070894P RESOLVE CLASS - 2 I OBSERVED IN THE METER AREA AT THE REAR OF THE MAIN ELECTRICAL ROOM EXCESSIVE STORAGE OF WOOD MATERIALS. PHOTOS TAKE... $0 $0 Nov 17, 2022
Sep 27, 2022 39070893N RESOLVE CLASS - 3 I OBSERVED ON ALL FLOORS IN THE LAUNDRY ROOM AND IN THE BASEMENT SEWER/LAUNDRY ROOM ELECTRICAL PANELS WITH THE BRANCH... $0 $0 Nov 17, 2022
May 24, 2022 39062774K RESOLVE CLASS - 2 I OBSERVED ON ALL FLOORS CONVENIENCE RECEPTACLES NOT OF THE TAMPER RESISTANT TYPE NOR MADE TAMPER PROOFED. THIS IS A ... $0 $0 Jul 14, 2022
May 24, 2022 39062771P RESOLVE CLASS - 2 FIRE PROOF SELF-CLOSING DOOR AT FIRST FL, BACK SIDE DOES NOT SELF-CLOSING PROPERLY WHEN INSPECTED., REPAIR/REPLACE DOOR $0 $0 Jul 14, 2022
May 24, 2022 39062775M RESOLVE CLASS - 2 I OBSERVED IN THE CHILDCARE ROOM NEXT TO THE SINK AND IN THE STORAGE CLOSET. THE INSTALLATION OF FEEDER WIRING , AN E... $830 $0 Jul 14, 2022
Apr 23, 2019 38269224H RESOLVE CLASS - 2 28-310447.THE OWNER SHALL HAVE A MAINTENANCE CONTRACT WITH AN APPROVEDAGENCY TO PERFORM ELEVATOR REPAIR WORK AND MAIN... $620 $0 Jun 20, 2019
Apr 23, 2019 38269223X RESOLVE CLASS - 1 5A10.52K2.52E10.67X10.78B14.59B10.98B7.(5A10)DOOR ZONE RESTRICTOR NOT WORKING TAMPERED WITH DISABLE.(52U2)HOIST CABLE... $1,250 $0 Jun 20, 2019
Mar 25, 2019 35401915N RESOLVE CLASS - 2 ELECTRICAL WORK W/O A PERMIT. OBSERVED IN THE WATER BOOSTER PUMP ROOM,THE INSTALLATION OF AN ELECTRIC HOT WATER HEATE... $400 $0 May 16, 2019
Mar 25, 2019 35401916P RESOLVE CLASS - 2 FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS. OBSERVED THE ARMORED CABLES TO SUPPLY BR... $400 $0 May 16, 2019
Jun 27, 2018 32097251R RESOLVE CLASS - 2 B254,50A,50B,50C,50D,50E. AS PER CLASS 2 (B254) 28.301.1 FAILURE TO MAINTAIN; 50A-NO SPILL SWITCH INSTALLED ON TWO EI... $312 $0 Aug 16, 2018
Apr 6, 2018 35328719H RESOLVE CLASS - 2 FAILURE TO SECURE/SUPPORT RACEWAYS/CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS.OBSERVED THROUGHOUT BASEMENT AREA EMT RAC... $400 $0 Sep 6, 2018
Apr 6, 2018 35328717Y RESOLVE CLASS - 2 LUMINAIRES AND LAMPHOLDERS NOT INSTALLED IN AN APPROVED MANNER.OBSERVED IN THE BASEMENT AREA THE INSTALLATION OF CHAI... $250 $0 Sep 6, 2018
Apr 6, 2018 35328716M RESOLVE CLASS - 2 UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,DEVICES,MATERIALS,APPARATUS,APPLIANCES AND OR WIRING IN USE.OBSERVE... $400 $0 Sep 6, 2018
Apr 6, 2018 35325719Y RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NO FIRE-STOPPING PRE BC 7123.;27-345.NOTED:OBSERVED AT CELLAR LEVEL... $0 $0 May 24, 2018
Apr 6, 2018 35328718X RESOLVE CLASS - 2 FAILURE TO PROPERLY CONNECT CONDUCTORS TO TERMINALS.OBSERVED IN ELEVATOR,DISCONNECT SWITCH THE TERMINATION OF TWO CON... $600 $0 Sep 6, 2018
Jan 27, 2018 35280195X RESOLVE CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35297191J ISSUED 12/06/17 AND TO FILE... $0 $0 Mar 15, 2018
Dec 12, 2017 38259573R RESOLVE CLASS - 2 8V1,69B7. 8V1 DEVICE IS OFF LEVEL ON FLOORS 4 & 5 ADJUST.69B7 CODE DATA PLATE IS NEITHER ETCHED OR PUNCHED(HAND WRITT... $250 $0 Feb 1, 2018
Dec 6, 2017 35297191J RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON 12/06/17 AT ABOVE ADDRESS GAS LEAK TO THE SUPPLY ON... $0 $0 Jan 25, 2018
Aug 23, 2017 35289818Y RESOLVE CLASS - 2 FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN WATER METER ROOM WATER MAIN GROUND CLAMP IN ... $0 $0 Apr 12, 2018
Aug 23, 2017 35289819X RESOLVE CLASS - 2 FAILURE TO PROPERLY LABEL/GROUP DISCONNECTS. OBSERVED IN ELECTRICAL SERVICE ROOM SERVICE DISCONNECT SWITCHES W/O LABE... $0 $0 Apr 12, 2018
Aug 23, 2017 35289820N RESOLVE CLASS - 2 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT,MATERIALS,APPARATUS DEVICE,APPLIANCE,OR WIRING IN USE. OBSERVED IN ... $0 $0 Apr 12, 2018
Aug 23, 2017 35289817M RESOLVE CLASS - 2 FAILURE TO PROVIDE)GFCI)GROUND FAULT CIRCUIT INTERRUPTER PROTECTION ASREQUIRED. OBSERVED IN ALL LAUNDRY ROOMS RECEPTA... $0 $0 Apr 12, 2018
Jun 10, 2017 35231706H RESOLVE CLASS - 2 FAILURE TO COMPLY W/COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35235484J ISSUED ON 03/27/17AND TO FILE A COFC... $400 $0 Jan 11, 2018
Mar 31, 2017 38253809R RESOLVE CLASS - 2 59M07. PERFORM & PROVIDE BRAKE MAINTENANCE TAG. $250 $0 May 18, 2017
Mar 31, 2017 38253810Y RESOLVE CLASS - 2 39I10,100P07,02I10,39O02,100I04,100Q06. (39I)REPAIR TOP OF CAR OUT RIGGER. (100P)PROVIDE ACCESS TO 5TH FLR. (02I)REPA... $250 $0 May 18, 2017
Mar 27, 2017 35235484J RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF MY INSPECTION I OBSERVED THE FOLLOWING FOR THE C... $2,500 -$2,500 May 11, 2017
Dec 10, 2016 35190529H RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35213843P ISSUED ON 10/19/16 & TO FILE A C OF C PURSUANT TO 28... $800 $0 Jan 26, 2017
Oct 19, 2016 35213843P RESOLVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.NOTE: BLDG RECORD SHOW THE C OF O AS A HOTEL W/... $2,400 $0 Jan 12, 2017
Sep 9, 2016 35207853H RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED ON 9/9/16 AT 11:25PM ON 2,3,4,5 FLR 2 OR MORE GAS DRYE... $1,000 $0 Oct 27, 2016
Sep 9, 2016 35207855L RESOLVE CLASS - 1 MISC VIOL. OBSEVED ON 9/9/16 AT 1:35PM IN BOILER ROOM-FUTURE GAS CONNECTION IN CEILING 4"PIPING AND 2"ELBOW 3X2 PLY. ... $1,000 $0 Oct 27, 2016
Sep 9, 2016 35207854J RESOLVE CLASS - 2 FAILURE TO PAINT DEDICATED S/D-- & VALVE IN ACCORDANCE W/ THIS SECTIONOBSERVED ON 9/9/16 @ 1:30PM IN STAIRWAYS 4TH FL... $800 $0 Oct 27, 2016
Jan 15, 2002 38120752X RESOLVE Non-Hazardous 15L11-3M7-16H12-11Q3-22L6-32Q3-37U16-43U16-43M5-74Y14. 15-L-11 NOT SELF CLOSING 1 & 2 FLOORS. 3-M-7 CAPACITY PLATE 16... $350 $0 Mar 7, 2002
Nov 21, 2000 38109375M RESOLVE Non-Hazardous 32M7,30H4,35#9.32-DUCT COVER MISSING TOP FL IN SHAFTWAY.30-PATCH ALL HOLES IN SHAFTWAY WALL.35-REMOVE WATER PIPE IIN ... $0 $0 Jan 11, 2001
Jul 25, 2000 38106224L RESOLVE Non-Hazardous 43Y14 43-SEAL HYDRO PISTON. $0 $0 Sep 14, 2000
Jul 21, 2000 34257463L RESOLVE Non-Hazardous FAILURE TO PROVIDE APPROVED PLANS AT TIME OF INSPECTION. NOTED:NO APPROVED PLANS ON PREMISES AT TIME OF INSPECTION RE... $0 $0 Sep 7, 2000
Jan 13, 2000 38093741J RESOLVE Non-Hazardous 73M,57Y. MISSING FOR A THREE YEAR TEST. PERFORM AND FILE TEST. $0 $0 Mar 2, 2000
Sep 25, 1996 34137461L RESOLVE Non-Hazardous OCCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY INT HAT THE ABOVE PREMISES IS NOW OCCUPIED AS A FAMIL... $0 $0 Dec 5, 1996
Dec 13, 1995 38053264J RESOLVE Non-Hazardous 03X,04M,74X,75T,15M,. 03X- OUTSIDE COMMUNICATION (PHONE/INTERCOM 04M- 5 PIN CYLINDOR & LOCK 74X- BUZZER FOR FIREMAN R... $1,000 $0 Feb 1, 1996
Jun 20, 1995 38049554X RESOLVE Non-Hazardous 73U,43Y,35Y,36W,57Z,55X,11Q,73O,22D. $200 $0 Aug 31, 1995
Jul 13, 1992 34076161N RESOLVE Hazardous FAILUR TO MAINTAIN-EXTERIOR NOTED: MASONAY BUILD BEARING WALL BROKEN, NURSING DEFECTIVE CREATING A HAZARDOUS CONDITIO... $800 $0 Sep 3, 1992