31-33 West 124 Street, Manhattan • Block 01722 • Lot 0022

40 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jan 16, 2024 39103506M ACTIVE CLASS - 2 CLEAN HOIST MACHINE., SEAL HOIST MACHINE., PROVIDE UP TO DATE MAINTENANCE LOG BOOK (LAST LOG BOOK AVAILABLE 2021)., C... $1,563 $0 Apr 10, 2025
Nov 15, 2023 35675364Y RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. AT TIME OF INSPECTION OBSERVED, A CRACK OF STONE LINTEL AT EXP... $2,500 $0 Mar 20, 2025
Nov 15, 2023 35675365X RESOLVE CLASS - 1 FILE A CERTIFICATE OF CORRECTION OR OTHER RELATED MATERIALS CONTAIN MATERIAL FALSE STATEMENT(S) NOTE: RESPONDENT FAIL... $1,250 $0 Mar 20, 2025
Sep 22, 2023 35675183P RESOLVE CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. NOTE: RESPONDENT FAILED TO COMPLY WITH PREVIOUS ISSUED EC... $2,500 $0 May 9, 2024
Aug 9, 2023 39092142J RESOLVE CLASS - 1 5/X/10 CAR DOOR RESTRICTOR IS NOT WORKING TAMPERED WITH REPAIR,52/H /12 HOIST ROPE WORN RESCHACKLE,55/H/12 DRUM COUNT... $1,250 $0 Oct 19, 2023
Aug 2, 2023 35674500P RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS, FACADE AND APPURTENANCES.OBSERVED CRACKED STONE ON EXPOSURE 1 SOUTH ELEV... $2,500 $0 May 2, 2024
Oct 19, 2022 37022816K RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $3,125 $0 Jun 22, 2023
Apr 6, 2022 39059634L RESOLVE CLASS - 2 FOUND SECONDARY BOILER ROOM DOOR NOT SELF CLOSING, REPAIR OR REPLACE, SAIL SWITCH MISSING AT COMBUSTION AIR FAN, SWIT... $310 $0 May 26, 2022
Jul 27, 2020 38273446P RESOLVE CLASS - 1 37B7: 37-B-7= PROVIDE SAFE ACCESS TO ELEVATOR OVERHEAD LOCATION (PROVIDE CAGE ON STEP LADDER OVER SIX FEET TO THE VER... $0 $0 Jan 21, 2021
Jul 15, 2020 39025465Y RESOLVE CLASS - 1 CAR CEASE USE CLASS 1 ELEVATOR COMPANY INSTALLED NEW GOVERNOR WITH OUT PERMIT. $6,250 $0 Oct 1, 2020
Jun 23, 2020 39024385J RESOLVE CLASS - 1 IN STALLED NEW GOVERNOR WITH OUT PERMIT, ONE YEAR TAG EXPIRED PROVIDE. MACHINE BRAKE TAG EXPIRED PROVIDE, DRUM COUNTE... $2,500 $0 Aug 13, 2020
May 21, 2020 39022575L RESOLVE CLASS - 1 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB CLASS I. $1,280 $0 Dec 3, 2020
Jan 10, 2020 38273003X ACTIVE CLASS - 1 42M07,37P16,54B12,55B12,56Y13,59BB07,68B07,70O02,71Q07,71X10,71M07,52B12,98BB05:42-M-07 NO DOOR LOCK MONITORING INSTA... $1,250 $0 Mar 19, 2020
Sep 26, 2019 38271791R RESOLVE CLASS - 2 59-BB-7,59-B-2,61-M-7,68-M-7=(59,BB,7) BRAKE MAINATENANCE TAG EXPIRED (59,B,2) CLEAN OIL OFF THE BRAKE DRUM (61,M,7) ... $625 $0 Mar 12, 2020
May 2, 2019 38269675R RESOLVE CLASS - 1 2X10,52BB12,55BB12,59BB7,70O2,99BB7,5A10;2.X.10 OUTSIDE COMM INOPERATIVE REPAIR,52.BB.12HOIST ROPES EXPIRED TAG RESHA... $1,250 $0 Aug 22, 2019
May 7, 2018 35313293H RESOLVE CLASS - 2 UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL,EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APPLIANC OR WIRING IN USE.FIRST FLOOR E... $400 $0 Jun 21, 2018
Mar 14, 2018 35265172H RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING EXERIOR WALLS/FACADES AND APPURTENANCES. ROOF: ERODED CORNICE, CRACKS AT ALL ELEVTIONS, ... $0 $0 May 3, 2018
Jun 16, 2017 38255498H RESOLVE CLASS - 1 CU-05O06; 02X10,15M07,37I10,39O02,52B12,68B07,70O02. 05D- 2-SPEED CAR DOOR UNSECURED TOP BOLTS MISSING BRACKET (SHOE)... $1,000 $0 Nov 30, 2017
Jun 8, 2017 38256636L RESOLVE CLASS - 1 97 X 17 97)ENTIRE DEVICE INOPERATIVE X)REINSPECTION REQUIRED THE ONLY ELEVATOR IN BUILDING OUT OF SERVICE UPON INSPEC... $1,000 $0 Nov 30, 2017
Aug 23, 2016 38244960P RESOLVE CLASS - 2 68B07,70O02,71B07,55BB12. 55-RESHACKLE DRUM SIDE HOIST ROPES. $0 $0 Oct 13, 2016
Nov 16, 2015 35161439L RESOLVE CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: AT EXP#4 EXIT PASSAGEWAY FROM REAR YARD TO THE FRONT OF THE B... $1,200 $0 Mar 17, 2016
Jun 15, 2015 38236528X RESOLVE CLASS - 1 56Y13,56Y02,61T07,54U12,55U12,31O02,07M07,28H11,10K11,05J01,12Q03. 56Y13-SEAL HOIST MACHINE OIL LEAK; 56Y02-CLEAN OIL... $1,000 $0 Sep 3, 2015
Jun 19, 2013 35009766M RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION. SIDEWALK SHED EXP #1 NO PLANS ON SITE. ... $0 $0 Aug 8, 2013
Feb 21, 2013 35001702R RESOLVE CLASS - 1 *FAILURE TO TAKE AND PROVIDE SAFETY MEASURES WHERE REQUIRED TO PROTECTAND SECURE PUBLIC SAFETY FROM UNSAFE FACADE AS ... $2,400 $0 Apr 11, 2013
Mar 8, 2012 34896507P ACTIVE CLASS - 2 905.3.1:REQUIRED STANDPIPE SYSTEM NOT INSTALLED. IN THE SEVEN STORIES SRO BUILDING A REQUIRED STANDPIPE SYSTEM IS NOT... $800 $0 Jun 14, 2012
Mar 6, 2012 34896438K ACTIVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER, WITNESS IN ADEQUATE SPRINKLER MAIN 3" INSTALLED FOR ESTIMATED ... $1,000 $0 Jun 14, 2012
Jul 20, 2011 38216967J RESOLVE CLASS - 2 56Y13 68B07 39O02 39BB12 33B12 61M07 37B10 14L11 67X10. 68B-PROVIDE INFO IN MAINTENANCE LOG. 39BB,33B-RESHACKLE CAR &... $500 $0 Sep 8, 2011
Dec 21, 2009 38208321K RESOLVE CLASS - 2 37T07 39O02 67X10 70O02 77Q03 37-PROVIDE SIGN FOR OVERHEAD SHEAVE ROOM DOOR 67X-REPAIR COMMUNICATION IN CAR TELEPHONE... $500 $0 Jul 15, 2010
Jun 30, 2005 34458846J RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... $1,750 $0 Sep 15, 2005
Apr 29, 2005 34458468L RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... $1,750 $0 Jul 14, 2005
Nov 12, 2004 34462316Y RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... $700 $0 Mar 18, 2005
Jun 25, 2004 34459524L RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $0 $0 Aug 26, 2004
Mar 26, 2004 34460273Y RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... $0 $0 Jun 17, 2004
Apr 3, 1996 38055667N RESOLVE Non-Hazardous 7#,50Y,50Y,52I,63H,74#,. 37#- FILE APPLICATION AND OBTAIN PERMIT FOR CONTROLER REPLACEMENT DUE TO FIRE 52- RESURFACE ... $5,000 $0 Jan 30, 1997
Apr 11, 1995 38048572P RESOLVE Non-Hazardous 03I, 50Y, 50Y, 62K, 62M, 63H, 73U. 30I-WALLS. 62K-ROTTEN SHEET METAL. 62M-TOE GUARD. $200 $0 Sep 7, 1995
May 13, 1994 34108028H RESOLVE Hazardous FAILURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALL ANAD APPURTENANCES AS REQUIRED... $500 $0 Feb 2, 1995
Jun 2, 1993 38034168X RESOLVE Non-Hazardous 73#, RESTORE TO SERVICE, SO THAT A FULL INSPECTION CAN MADE BY THIS DEPT. $500 $0 Jul 15, 1993
Apr 27, 1992 38024613X RESOLVE Non-Hazardous 73X, RESTORE TO SERVICE SO THAT A PROPER INSPECTION CAN BE MADE BY THIS DEPARTMENT. $375 $0 Jun 24, 1992
Jul 18, 1991 38014997P RESOLVE Hazardous 73X,73O,33P,35W,36M,35O,31Q,53X,20M,14M,38X,46#,49#3M,(73) RESTORE TO SERVICE SO THAT A PROPER INSPECTION CAN BE MADE... $375 $0 Oct 2, 1992
Mar 19, 1991 38009602P RESOLVE Non-Hazardous 73X,73O,33P,35P,37I,46#,49#,3M,10I,35O, 3-CAPACITY PLATE-RESTORE TO SERVICE SO THAT A COMPLETE INSPECTION CAN BE MADE... $150 $0 Aug 22, 1991