ECB violations
59 West 142 Street, Manhattan • Block 01740 • Lot 0007
42 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 7, 2026 | 39194989M | ACTIVE | CLASS - 1 | VF.... CEASE USED... DOOR RESTRICTOR NOT WORKING...DOOR ZONE RESTRICTOR HAS BEEN TEMBERED WITH DISABLED AND RENDERED ... | $1,250 | $1,250 | Sep 10, 2026 |
| Mar 22, 2025 | 35690034R | ACTIVE | CLASS - 1 | 28-323.8 AND RCNY 103-13(5). FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES C... | $12,500 | $12,500 | May 29, 2025 |
| Sep 19, 2024 | 39125295Z | ACTIVE | CLASS - 2 | CLASS 2: MACHINE IS LEAKING OIL, NEED TO REPAIR OIL LEAK. BRAKE MAINTENANCE TAG IS EXPIRED, MARCH 2023, NEED TO PERFO... | $625 | $0 | Dec 5, 2024 |
| Sep 19, 2024 | 39125294R | RESOLVE | CLASS - 2 | CLASS 2: THE OIL LEVEL IS LOW IN THE GEARBOX FOR THE MACHINE, LOW ENOUGH WHERE WORM WHEEL IS BARELY CARRYING OIL. BRA... | $625 | $0 | Dec 5, 2024 |
| Nov 10, 2022 | 39073702P | RESOLVE | CLASS - 2 | CLASS 2: 39.I.10 CAR TOP BOX & WIRING DAMAGED. REPAIR & SECURE BOX TO CROSS HEAD. PIN GREENFIELD TO CROSSHEAD & CAR T... | $0 | $0 | Dec 29, 2022 |
| Aug 8, 2022 | 39067559K | ACTIVE | CLASS - 1 | UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE. RESTORE TO SERVICE IMMEDIATELY AND CONTACT NYCDOB AT EIR@BUILDINGS.N... | $6,250 | $0 | Sep 22, 2022 |
| Nov 4, 2021 | 39050611H | RESOLVE | CLASS - 1 | FOUND DOOR LOCK MONITORING IS NOT WORKING. CEASE USED. REPAIR AND ADJUST. RE-INSPECTION IS REQUIRED. PHONE IN CAR IS ... | $1,250 | $1,250 | Dec 23, 2021 |
| Sep 23, 2020 | 39029266J | ACTIVE | CLASS - 1 | CLASS 1 VIOLATION NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3. 10.12 OF APPENDIX K3 OF THE ... | $6,250 | $0 | Dec 31, 2020 |
| Sep 23, 2020 | 39029267L | ACTIVE | CLASS - 1 | CLASS 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC.... | $6,250 | $0 | Dec 31, 2020 |
| Jun 17, 2020 | 39024104Y | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $6,250 | $0 | Sep 3, 2020 |
| Jun 17, 2020 | 39024105X | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $6,250 | $0 | Sep 3, 2020 |
| May 26, 2020 | 39022728N | ACTIVE | CLASS - 1 | CLASS 1 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB. | $1,250 | $0 | Jul 16, 2020 |
| Mar 18, 2019 | 38268951J | RESOLVE | CLASS - 1 | 97-X-17 OUT OF SERVICE ,UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERVICE .REMEDY:RESTORE TO SERVICE IMMEDIATE... | $1,250 | -$1,250 | Jun 6, 2019 |
| Feb 27, 2019 | 38268215L | RESOLVE | CLASS - 1 | 97X17 RESTORE TO SERVICE FOR PROPER INSPECTION BY DOB. | $1,250 | $0 | Apr 25, 2019 |
| Dec 18, 2017 | 38257363J | RESOLVE | CLASS - 2 | 58Y13,77I11,100B7. (58Y)SEAL OIL LEAKS AROUND SHEAVE. (77I)REPLACE BROKEN TRAVEL CABLE KELLUM GRIP UNDER ELEVATOR CAB... | $0 | -$500 | Feb 1, 2018 |
| Jan 4, 2017 | 35210172J | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG ROOF-WATER TOWER BRICK ENCLOSURE VERTICAL AND HORIZONTAL CRACKS; ERODED SEALANTS;RO... | $2,500 | $0 | Feb 23, 2017 |
| Oct 28, 2016 | 38250707M | RESOLVE | CLASS - 2 | 05N1 RESTRICTOR IS NO OPERATIVE. | $0 | $0 | Dec 15, 2016 |
| Oct 28, 2016 | 38250706K | RESOLVE | CLASS - 2 | 05N1,59M7,52B7,88D1. 05N1-RESTRICTOR NO OPERATIVE; 59H78-MISSING BREAK TAG; 52B7-INSUFFICIENT RUNBY. | $0 | $0 | Dec 15, 2016 |
| Aug 25, 2016 | 35173778Y | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG GENERAL NOTE:UNSECURED SCREEN 1/2 AND MISSING GRILLS AT A/C UNITS-CORNER SOFFITS SP... | $500 | $0 | Oct 13, 2016 |
| Aug 11, 2016 | 37001069N | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPUR... | $4,000 | $0 | Mar 2, 2017 |
| Jul 8, 2016 | 38244175J | RESOLVE | CLASS - 1 | 05M07,56Y02,56Y13,10H11,17H11. DOOR RESTRICTOR MISSING PROVIDE, HOIST MACHINE OIL LEAK CLEAN, HOIST MACHINE OIL LEAK ... | $1,000 | $0 | Aug 25, 2016 |
| May 31, 2016 | 38243134Z | ACTIVE | CLASS - 1 | 97-X-10:FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER;SERVICE EQUIPMENT.ELEVATOR AS PER BC 3001.2 & 27-979.DOB RE... | $5,000 | $0 | Jul 21, 2016 |
| May 25, 2016 | 38242779L | ACTIVE | CLASS - 1 | 97X10 RETURN ELEVATOR BACK TO SERVICE | $5,000 | $0 | Jul 14, 2016 |
| Oct 8, 2015 | 35133656J | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING.NOTED: NORTH ELEVATION EXP#1 CRACKED DETERIORATING MASONRY AT PARAPET, SPALLING... | $500 | $0 | Jan 14, 2016 |
| Jul 19, 2014 | 35073698X | RESOLVE | CLASS - 3 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OF BLDG DEPT RECORDS.NOTED: BLDG IS 15 FLS HIGH PLUS BULKHEAD WHICH ... | $0 | -$400 | Oct 9, 2014 |
| Oct 22, 2012 | 38223617P | ACTIVE | CLASS - 2 | 02X10;100X10. 100X-REPAIR DISPATCHER (CARS STOPPING ON EVERY FLOOR REPAIR) | $500 | $0 | Dec 6, 2012 |
| Aug 8, 2012 | 38222558J | ACTIVE | CLASS - 2 | 56Y10,56Y13,56Y02,68B07,39Y02. 56Y:REPAIR & SEAL GLOW PACKING. 68B:PROVIDE CURRENT INFO IN LOG BOOK. | $2,500 | $0 | Sep 27, 2012 |
| Aug 8, 2012 | 38222559L | ACTIVE | CLASS - 2 | 56Y10,56Y03,56Y02,69B07,39Y02. 56Y:REPAIR & SEAL GLOW PACKING.68B:PROVIDE CURRENT INFO IN LOG BOOK. | $2,500 | $0 | Sep 27, 2012 |
| Feb 2, 2011 | 38214272Y | ACTIVE | CLASS - 2 | 41T07,68M07,11X10,67X10,53E10,78B14,80B14.(41T)LABEL M.R. DOOR.(11X)REPAIR LIGHTS ON PUSH BUTTON STATION.(67X)REPAIR ... | $500 | $0 | Mar 24, 2011 |
| Feb 2, 2011 | 38214271M | ACTIVE | CLASS - 2 | 56Y10,56Y13,56Y02,68M07,41T07,61M07,39Y02,67X10,80B14,70O02.(56Y)REPAIR & SEAL GLOW PACKING.(41T)LABEL M.R. DOOR.(61M... | $500 | $0 | Mar 24, 2011 |
| Dec 7, 2009 | 34744465N | ACTIVE | CLASS - 2 | FAILURE TO PROVIDE SAFETY MEASURES AND SIDEWALK SHED WHERE REQUIRED ACCORDING TO THE CYCLE #6 TECHNICAL REPORT FILES ... | $10,000 | $0 | Jan 28, 2010 |
| Jan 25, 2008 | 32055539K | RESOLVE | Non-Hazardous | B4A,50,50A,34A.50-BOILER FLUE UPPER CLEANOUT DOOR.BOTTOM LATCH BROKEN INTO CHIMNEY.50A-CLOSABLE LOUVERS IN FRESH AIR ... | $180 | -$180 | Mar 13, 2008 |
| Aug 13, 2007 | 38168913K | RESOLVE | Non-Hazardous | 84I10/38O2/.84-REPAIR DAMAGED LIGHT TO OF ELEVATOR.38-CLEAN TOP OF ELEVATOR OF ALL OIL. | $0 | $0 | Oct 11, 2007 |
| Mar 21, 2007 | 32053317X | RESOLVE | Hazardous | B4B,BQ9.BQ9-EXISTING KEWANI BOILER REMOVED AND NEW ROCKMILLS BOILER INSTALLED WITHOUT PERMITS OR EMERGENCY ARA. | $1,050 | $0 | Aug 16, 2007 |
| Mar 21, 2007 | 32053318H | RESOLVE | Hazardous | B4B, BQ9:EXISTING KEWANI BOILER REMOVED WITHOUT PERMIT, OR EMERGENCY ARA; ALSO BASE FOR NEW BOILER CEMENTED INTO PLACE. | $1,050 | $0 | Aug 16, 2007 |
| Nov 14, 2005 | 38154899X | RESOLVE | Non-Hazardous | 83P16. 83-P16 RESTORE ELEVATOR BACK TO SERVICE SO THAT A PROPER INSPECTION CAN BE DONE BY THIS DEPARTMENT. | $180 | $0 | Dec 29, 2005 |
| May 28, 2003 | 34401139N | ACTIVE | Non-Hazardous | VIOLATION PARKING REGULARTIONS IN A RESIDENTIAL DISTRICT NOTED STREET LEVEL OPEN PARKING DEAD STORAGE OF A 1986 RED F... | $0 | $0 | Jul 17, 2003 |
| Feb 5, 2001 | 38111384R | RESOLVE | Non-Hazardous | 15J11 18Q3 55X11. 15J11-TOO MUCH GAP TO BUCK, 18Q3-1,2,11,12,14&15. | $0 | $0 | Mar 22, 2001 |
| Feb 5, 2001 | 38111383P | RESOLVE | Non-Hazardous | 15J11, 18Q3, 50T16. 15J11-TOO MUCH GAP TO BUCK 1ST FL. 18Q3-1ST & 15 FL. | $0 | $0 | Mar 22, 2001 |
| Mar 10, 2000 | 38095341J | RESOLVE | Non-Hazardous | 09H12,04P17,75U16,15J11. 75U16- TAG DEVICE 15J11- TOO MUCH GAP TO BUCK | $180 | $0 | Apr 27, 2000 |
| Mar 10, 2000 | 38095342L | RESOLVE | Non-Hazardous | 07P17,7J1,15J11,75U16. 15J11- TOO MUCH GAP TO BUCK 75U16- TAG DEVICE | $180 | $0 | Apr 27, 2000 |
| Mar 5, 1990 | 34033920P | ACTIVE | Unknown | FAILURE TO HAVE APPROVED PA PLANS AVAILABLE FOR INSPECTION. REMEDY: PROVIDE APPROVED PA PLANS. | $250 | $0 | Apr 19, 1990 |