ECB violations
East 121 Street, Manhattan • Block 01747 • Lot 0070
22 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 11, 2024 | 37027260R | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B AND 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTE... | $1,250 | $0 | Jun 13, 2024 |
| Mar 30, 2021 | 39038772R | RESOLVE | CLASS - 1 | CLASS 1, DLM, NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 ... | $1,250 | $0 | May 12, 2021 |
| Mar 30, 2021 | 39038771P | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 O... | $1,250 | $0 | May 12, 2021 |
| Mar 30, 2021 | 39038770N | RESOLVE | CLASS - 2 | CLASS 2, COUNTERWEIGHT RUN-BY LOW REMEDY, SHORTEN ROPES | $625 | $0 | May 12, 2021 |
| Mar 26, 2021 | 39038406R | RESOLVE | CLASS - 1 | RTS VIOLATION ISSUED UPON INSPECTION OF DEVICE IT WAS FOUND OUT THAT THE DEVICE WAS NOT WORKING REMEDY; RESTORE TO SE... | $1,250 | $0 | Apr 15, 2021 |
| Aug 14, 2013 | 34932417R | RESOLVE | CLASS - 1 | FILED A CERTIFICATE, FORM, APPLICATION ETC. CONTAINING MATERIAL FALSE STATEMENTS. IN 7.22.13 JOHN M. BOTTO, LMP #1319... | $0 | $0 | Oct 24, 2013 |
| Feb 15, 2013 | 34989737N | RESOLVE | CLASS - 2 | SEC. 1RCNY-901(G) SPECIALLY CREW: WHERE RIGGING WORK IS BEST HANDLED BY OR RIQUIRES CREWS OF A SPECIALITY TRADE,A LET... | $400 | $0 | Apr 4, 2013 |
| Feb 5, 2013 | 34989698J | RESOLVE | CLASS - 1 | SEC. 9-01 RIGGER FAILED TO DESIGNATE A FOREMAN. NOTED: MR. ADAM J MAJDA WORKING ON A 2 POINT SUSPENDED SCAFFOLD DID N... | $1,600 | $0 | Mar 28, 2013 |
| Feb 5, 2013 | 34989699L | RESOLVE | CLASS - 1 | LICENSED RIGGER FAILED TO EXPOSURE SCAFFOLD WORKER MET MINIMUM REQUIREMENTS. NOTED: MR. CARLOS M ACOSTA WORKING ON A ... | $1,600 | $0 | Mar 28, 2013 |
| Feb 5, 2013 | 34989725X | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS. NOTED: INSTALLATION OF OUTRIGGER BEAMS ARE CONTRARY TO APPR... | $0 | $0 | Mar 28, 2013 |
| Dec 18, 2012 | 34996998R | RESOLVE | CLASS - 1 | FAIL TO SAFEGUARD ALL PERSONS.NOTED:SERVICE LINES & CABLES CONSTITUE A TRIPPING HAZARD.@INSP OBS ELECTRIC EXTENSION C... | $2,400 | $0 | Feb 7, 2013 |
| Dec 18, 2012 | 34996997P | RESOLVE | CLASS - 2 | 3301.2 FAIL TO INSTITUTE &MAINTAIN SAFETY EQUIP MEASURES OR TEMP CONST-HOLES IN FLOOR.NOTED:@INSP OBS HOLES APPROX 4"... | $0 | $0 | Feb 7, 2013 |
| Dec 18, 2012 | 34996999Z | RESOLVE | CLASS - 1 | FAIL TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.NOTED:LOOSE DEBRIS ON LVL #7(ROOF) UNSECURED,BANDED O... | $2,400 | $0 | Feb 7, 2013 |
| Nov 27, 2012 | 34987021Z | RESOLVE | CLASS - 2 | BC33012-FAILURE TO INSTITUTE AND MAINTAIN SAFETY EQUIPMENT MEASURS OR TEMPORARY CONSTRUCTION.HOLES IN FLOOR:UPON INSP... | $0 | $0 | Jan 17, 2013 |
| Sep 25, 2012 | 34988022P | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION NO TOE BOARDS!UPON INSPECTION AS NO... | $0 | $0 | Dec 13, 2012 |
| Aug 29, 2012 | 34988016Z | RESOLVE | CLASS - 1 | 3303.12:FAILURE TO PROVIDE TEMPORARY HOIST. UPON INSPECTION AS NOTED ON ACTIVE CONSTRUCTION SITE WORKERS FORMING ROOF... | $0 | $0 | Dec 13, 2012 |
| Aug 14, 2012 | 34988008Z | RESOLVE | CLASS - 1 | SEC. 3303.11.1. FAILURE TO PROVIDE REQUIRED STWYS: PARTIAL SWO: ON ALLWORK ABOVE 50' ISSUED PURSUANT TO 28.207.2 & PO... | $0 | $0 | Dec 13, 2012 |
| Jul 18, 2012 | 34885669Y | RESOLVE | CLASS - 1 | 3320.2 OPERATION OF DEFECTIVE HOISTING EQUIPMENT. AT TIME OF INSPECTION FALL (MAIN HOIST CABLE) BROKEN STRAND FOUND. ... | $1,600 | $0 | Jun 27, 2013 |
| Jul 18, 2012 | 34885670L | RESOLVE | CLASS - 1 | OPERATION OF DEFECTIVE HOISTING EQUIPMENT. AT TIME OF INSPECTION MID FALL (MAIN HOIST CABLE) HAS BROKEN WIRE. RMDY: R... | $0 | $0 | Aug 8, 2013 |
| Jul 3, 2012 | 34954228P | RESOLVE | CLASS - 2 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS UPON INSPECTION AS NOTED ON ACTIVE C... | $250 | $0 | Aug 23, 2012 |
| Jul 3, 2012 | 34954229R | RESOLVE | CLASS - 2 | SEC. 3301.7 FAILURE TO PROVIDE DESIGNED DRAWING. UPON INSPECTION AS NOTED ON ACTIVE CONSTRUCTION SITE CONCRETE OPERAT... | $400 | $0 | Aug 23, 2012 |
| Apr 12, 2012 | 34953675M | RESOLVE | CLASS - 1 | NO CONCRETE SAFETY MANAGER PRESENT DURING AL CONCRETE OPERATION AS REQQUIRED: UPON INSPECTION AS NOTED ON ACTIVE CONS... | $2,400 | $0 | May 31, 2012 |