ECB violations
307 East 119 Street, Manhattan • Block 01796 • Lot 0006
12 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 3, 2022 | 39508685M | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF CLASS1 VIO#39505253P ISSUED ON 08-18-22 FOR CONTINUING TO WORK WHILE UNDER STOP WORK ORDER. ... | $3,125 | $3,125 | Dec 22, 2022 |
| Aug 18, 2022 | 39505253P | ACTIVE | CLASS - 1 | ALL FACADE WORK COMPLETED AND SIDEWALK SHED WITH SUPPORTED SCAFFOLD WERE REMOVED DURING STOP WORK ORDER IN PLACE. | $25,000 | $25,000 | Oct 6, 2022 |
| Jun 7, 2021 | 35574250N | ACTIVE | CLASS - 2 | TEMP CONST EQUIPMENT ONSITE-EXPIRED SWS PERMIT ATOI OF THIS 4STYBLDG IOBSERVED SWS ON EXP1.NO ACTIVE PERMIT ON BLDGS ... | $1,250 | $0 | Aug 19, 2021 |
| Jun 7, 2021 | 35574251P | ACTIVE | CLASS - 2 | SWS PARAPET PANEL ATOI OF THIS 4STYBLDG I OBSERVED SWS IN POOR CONDITION MISSING 2PARAPET PANELS NEAR EXP4.COMPLY W/C... | $6,250 | $6,250 | Aug 19, 2021 |
| Jun 7, 2021 | 35574252R | ACTIVE | CLASS - 1 | BC3314.8.2&BC3314.1 FAILURE TO MAINTAIN SCF AS PER CODE (NETTING&PLANKS) ATOI OF THIS 4STYBLDG I OBSERVED SCF MISSING... | $12,500 | $12,500 | Aug 19, 2021 |
| Oct 24, 2020 | 35499561N | ACTIVE | CLASS - 1 | BC33141-INADEQUATE SCAFFOLD(PIPE)AT TIME OF MY INSPECTION I OBSERVED A4 STORY OCCUPIED BUILDING WITH A ERECTED PIPE S... | $12,500 | $12,500 | Feb 24, 2022 |
| Oct 24, 2020 | 35499560L | ACTIVE | CLASS - 1 | FAILRUE TO COMPLY WITH MANUFACTOR SPECIFICATIONS.AT TIME OF MY INSPECTION I OBSERVED A 4 STORY OCCUPIED BUILDING WITH... | $12,500 | $12,500 | Feb 24, 2022 |
| Oct 24, 2020 | 35499562P | ACTIVE | CLASS - 2 | FAILURE TO PROVIDE PEDESTRIANS PROTECTION.AT TIME OF MY INSPECTION OF A 4 STORY BUILDING OCCUPIED.I OBSERVED A SIDEWA... | $10,000 | $10,000 | Feb 24, 2022 |
| Oct 24, 2020 | 35499563R | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED.AT TIME OF MY INSPECTION OF A 4 STORY BUILDING OCCUPIED I OBSERVED A... | $1,250 | $1,250 | Nov 18, 2021 |
| Oct 20, 2020 | 35542806N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES NOTE AT EXPOSURE #1 AND #4 BROKEN BOWNSTONES WINDOW SILLS AT 3RD ... | $6,250 | $6,250 | Dec 2, 2021 |
| Jun 9, 2020 | 39023697Y | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTED MULTIPLE DEFECTS AT EXPOSURE #1 INCLUDING BULGING MASONRY ... | $2,500 | $0 | Jun 3, 2021 |
| Jun 28, 1993 | 34094877H | ACTIVE | Hazardous | FAILURE TO MAINTAIN INTERIOR NOTED STAIRS STRINGER PULLING AWAY FROM BEARING POINT THREADS & RISERS PULLING AWAY FROM... | $800 | $0 | Aug 19, 1993 |