ECB violations
East 120 Street, Manhattan • Block 01808 • Lot 0001
63 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 26, 2026 | 39181963L | RESOLVE | CLASS - 2 | DLM NOT INSTALLED NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2... | $625 | $0 | Apr 7, 2026 |
| Apr 11, 2024 | 37027231H | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027232J | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027233L | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027234N | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION EXTERIOR WALL ... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027235P | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027236R | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027237Z | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027227P | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027226N | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027225L | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027230X | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027229Z | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Apr 11, 2024 | 37027228R | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $1,250 | $0 | Jun 13, 2024 |
| Nov 28, 2022 | 39074581M | RESOLVE | CLASS - 2 | LOW PRESSURE STEAM LEAK IN 1ST AVE GARDEN AREA ON UNDERGROUND SUPPLY PIPE. JOHNSON BOILER MODEL#7 HAS EXPOSED WIRING ... | $625 | $0 | Dec 8, 2022 |
| Feb 17, 2022 | 39056327H | RESOLVE | CLASS - 2 | PRESSURE SWITCH COVERS MISSING-ELECTRICAL CONNECTION BOXES ON BOILERS W/O COVERS-CONDENSATE RETURN FLOODING BOILER-ST... | $625 | $0 | Mar 7, 2022 |
| Apr 4, 2017 | 38254455N | RESOLVE | CLASS - 2 | 02B10, 70O02. (02-B-10) REPAIR IN CAR PHONE (70-O-02) DINTY PIT. | $0 | $0 | May 11, 2017 |
| Jul 7, 2011 | 34872534Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEVATION EXP#1 OBSERVE MASONRYBARK UNDER A/C UNIT WEST ELEVATION EXP#3 OBSERV... | $0 | $0 | Sep 15, 2011 |
| Jul 7, 2011 | 34872532K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BLDG EAST ELEVATION EXP#1 OBSERVE BLOCKS OF WOOD UNDER A/C UNITS SLOPING A/C UNIT IN FAC... | $0 | $0 | Sep 15, 2011 |
| Dec 17, 2010 | 36015894Y | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $0 | $0 | May 5, 2011 |
| Dec 17, 2010 | 36015895X | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $0 | $0 | May 5, 2011 |
| Jun 25, 2010 | 36013826N | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMNDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS... | $0 | $0 | Aug 19, 2010 |
| Jun 25, 2010 | 36013827P | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMNDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS... | $0 | $0 | Aug 19, 2010 |
| Mar 1, 2010 | 34744549K | RESOLVE | CLASS - 2 | LLREPORT FILED"UNSAFE"BY ARCH/ENG,NO AMENDED REPORT WAS FILED. "UNSAFECONDITION"REQUIRE SAFETY PROVISIONS FOR THE PUB... | $0 | $0 | Apr 22, 2010 |
| Mar 1, 2010 | 34744548Z | RESOLVE | CLASS - 2 | LLREPORT AS"UNSAFE"BY ARCH/ENG.NO AMENDED REPORT WAS FILED."UNSAFE CONSTRUCTION"REQUIRES SAFETY MEASURES FOR THE PUBL... | $0 | $0 | Apr 22, 2010 |
| Dec 23, 2009 | 36011448X | RESOLVE | CLASS - 2 | FAIL TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIB... | $0 | $0 | Mar 18, 2010 |
| Dec 23, 2009 | 36011450P | RESOLVE | CLASS - 2 | FAIL TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIB... | $0 | $0 | Mar 18, 2010 |
| Oct 28, 2009 | 34815882J | RESOLVE | CLASS - 1 | SEC 28-404.1 MISC VIOL: SUPERVISION OR USE OF RIGGING EQUIPMENT W.O A RIGGERS LICENSE. NOTED: ELECTRICAL MATERIAL HOI... | $0 | $0 | Apr 6, 2010 |
| Oct 28, 2009 | 34815884N | RESOLVE | CLASS - 1 | SEC 28-404.1 MISC VIOL: SUPERVISION OR USE OF RIGGING EQUIPMENT W.O A RIGGERS LICENSE. NOTED: ELECTRIC MATERIAL HOIST... | $0 | $0 | Apr 6, 2010 |
| Aug 5, 2009 | 38205045J | RESOLVE | CLASS - 1 | 39A10.70O2.11L10.60Q3.42G7.39A10 PLANK SW. JUMPED CUI 11L10 DOOR OPEN BUTTON | $0 | $0 | Sep 24, 2009 |
| Aug 5, 2009 | 38205388L | RESOLVE | CLASS - 2 | 14H11.39X10.69M7 14H REPLACE DIRTY MIRROR 52K ROUGE REPLACE 39X STOP SW REQUIRES IMMEDIATE ATTENTION 42G UNREADABLE F... | $0 | $0 | Sep 24, 2009 |
| Aug 5, 2009 | 38205044H | RESOLVE | CLASS - 2 | 41T7.11L10.70O2.60Q3.11L10 DOOR OPEN BUTTON | $0 | $0 | Sep 24, 2009 |
| Aug 5, 2009 | 38205383M | RESOLVE | CLASS - 1 | 01X10.53B14.69M7.CUI 01X IN CAR STOP SW INOPERATIVE 17HD REPLACE SECURE WHERE NEEDED 42G UNREADABLE FUSES 97V INTERMI... | $0 | $0 | Sep 24, 2009 |
| Aug 5, 2009 | 38205385X | RESOLVE | CLASS - 2 | 42G11.52M7.53B14.42G UNREADABLE FUSES 60Q GUARDS MISSING 56Y SEAL LEAKS 69M PROVIDE CODE DATA PLATE 52M ANTI-SPIN DEV... | $0 | $0 | Sep 24, 2009 |
| Aug 5, 2009 | 38205386H | RESOLVE | CLASS - 2 | 17H11.10H11.71B01.17H REPLACE WHERE NEEDED 10H REPLACE 42G UNREADABLE FUSES 56Y SEAL LEAKS 69M CODE DATA PLATES 52M A... | $0 | $0 | Sep 24, 2009 |
| Aug 5, 2009 | 38205387J | RESOLVE | CLASS - 2 | 14H11.10H11.61P17. 14H REPLACE MIRROR 10H REPLACE 32H WORN CAR SHOES 27B REMOVE OLD TAGS 42G UNREADABLE FUSES 60Q GUA... | $0 | $0 | Sep 24, 2009 |
| Aug 4, 2009 | 38205382K | RESOLVE | CLASS - 2 | 10H11.59Y2.69M7 10H REPLACE 01.02.B MUTED BELL 11X DOOR OPEN BUTTON 42G UNREADABLE FUSES 56Y SEAL LEAKS 59Y CLEAN DRU... | $0 | $0 | Sep 24, 2009 |
| Aug 4, 2009 | 38205384Y | RESOLVE | CLASS - 2 | 42G11.10H11.42G UNREADABLE FUSES 69M PROVIDE CODE DATA PLATES 14H REPLACE MIRROR 10H REPLACE | $0 | $0 | Sep 24, 2009 |
| Aug 4, 2009 | 38205043X | RESOLVE | CLASS - 2 | 24B7.11L10.60Q3.70O2.10H11 24B7 POSITION INDICATORS IN CAR 11L10 DOOR OPEN BUTTON | $0 | $0 | Sep 24, 2009 |
| Aug 4, 2009 | 38205042Y | RESOLVE | CLASS - 2 | 60Q3.14O2.39O2.24B07 PI INSIDE CAR 56H10 WORM AND GEAR 11L10 DOOR OPEN BUTTON | $0 | $0 | Sep 24, 2009 |
| Jul 16, 2009 | 34784279X | RESOLVE | CLASS - 1 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: CONSTRUCTION WORK BEING DONE ... | $0 | $0 | Sep 10, 2009 |
| Jun 24, 2009 | 34788406H | RESOLVE | CLASS - 1 | LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQ. NOTED: WORKERS ON SUSPENDED SCAFFOLD W.O A CERTIFIC... | $0 | $0 | Apr 14, 2011 |
| Jun 24, 2009 | 34788405X | RESOLVE | CLASS - 1 | LICENSED RIGGER FAILED TO ENSURE SCAFFOLD WORKER MET MINIMUM REQ.NOTEDWORKERS ON SUSPENDED SCAFFOLD W.O A CERTIFICATE... | $0 | $0 | Apr 14, 2011 |
| Jun 24, 2009 | 34788408L | RESOLVE | CLASS - 1 | OPERATION OF HOISTING EQUIPMENT IN UNSAFE MANNER. NOTED: MATERIAL HOIST HAD FRAYED FLATTENED & BIRD CAGED IN SEVERAL ... | $4,800 | $0 | Jul 8, 2010 |
| May 22, 2009 | 36009326P | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $0 | $0 | Jul 23, 2009 |
| May 22, 2009 | 36009328Z | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $0 | $0 | Jul 23, 2009 |
| Dec 26, 2008 | 36007246X | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF... | $0 | $0 | Apr 16, 2009 |
| Dec 26, 2008 | 36007248J | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF... | $0 | $0 | Apr 16, 2009 |
| Dec 26, 2008 | 36007247H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF... | $0 | $0 | Apr 16, 2009 |
| Dec 26, 2008 | 36007245Y | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF... | $0 | $0 | Apr 16, 2009 |