Issued Violation Status Severity Description Penalty Balance due Hearing
Apr 11, 2024 37027765M ACTIVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... $6,250 $6,250 Nov 6, 2025
Oct 20, 2020 39030701N ACTIVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... $1,250 $1,250 May 6, 2021
Jul 15, 2020 39025410R ACTIVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF K3 2014 NYCBC. THIS IS A CONTROLLER FE... $6,250 $6,250 Sep 16, 2021
Jun 29, 2020 37019422K RESOLVE CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SSUMMONS/VIOLATION#35253639Y ISSUED ON 7/6/2017,AND TO FILE ... $0 $0 Mar 4, 2021
Oct 15, 2018 37013186K RESOLVE CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... $0 $0 Mar 21, 2019
Jul 6, 2017 35253639Y ACTIVE CLASS - 1 FAILURE TO TAKE AND PROVIDE SAFETY MEASURES WHERE REQUIRED TO THE PROTECTION AND SECURED PUBLIC SAETY FROM UNSAFE FAC... $2,400 $2,400 Apr 26, 2018
Mar 31, 2014 35066291Z ACTIVE CLASS - 1 WORK W/O A PERMIT ON 03/31/14 @ 2:00 P.M DURING PHYSICAL INSPECTION I OBSERVED 25 GAS METERS REMOVED IN THE CELLAR W/... $800 $0 Jun 26, 2014
Mar 31, 2014 35066293M RESOLVE CLASS - 1 GAS BEING SUPPLIED TO BLDG W/O INSPECTION & CERTIFICATION BY D.O.B DURING INSPECTION I OBSERVED 4 DRYERS IN USE IN TH... $0 $0 Jun 26, 2014
Mar 31, 2014 35038908L ACTIVE CLASS - 1 ELECTRICAL WORK W/O A PERMIT.THE ENTIRE APT9C & APT9B ONLY SUB PANEL:SUB PANELS BRANCH CIRCUIT WIRNG,RECEPTACLE OUTLE... $8,000 $0 Jul 31, 2014
Mar 31, 2014 35038909N ACTIVE CLASS - 1 215.2 FEEDER CONDUCORS SHALL BE SIZED SO THAT THE MAXIMUM VOLTAGE DROP@ THE LAST OVERCURRENT DEVICE DOES NOT EXCEED 3... $8,000 $0 Jul 31, 2014
Mar 31, 2014 35038910K ACTIVE CLASS - 1 FAILURE TO PROPERLY BOND ELECTRICAL SYSTEMS.BSMT SERVICE EQUIPMENT:2.4000 AMPERS ARE NOT BONDED TO ENCLOSURES!!! REM:... $15,000 $0 Jul 31, 2014
Mar 31, 2014 35038911M ACTIVE CLASS - 1 250.64(D)THE EXOTHERMIC WELDING PROCESS.TOP CONDUCTORS SHALL BE CONNECTED TO THE COMMON GROUNDING ELECTRODE CONDUCTOR... $8,000 $0 Jul 31, 2014
Mar 31, 2014 35038913X ACTIVE CLASS - 2 FAILURE TO INSTALL GROUND-FRUIT CIRCUIT INTERRUPTION (GFCI)PROTECTION AS REQUIRED 9C KITCHEN:NO GFCI CIRCUIT PROVIDED... $10,000 $0 Jul 31, 2014
Mar 31, 2014 35066295X ACTIVE CLASS - 1 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.DURING PHYSICAL INSPECTION I OBSERVED 4 DRYERS & GAS LINES IN U... $250 $0 Jun 26, 2014
Mar 31, 2014 35038912Y RESOLVE CLASS - 3 110.25 ELECTRICAL CLOSETS:ELECTRICAL CLOSETS OR ROOMS SHALL BE DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT.ELECTRI... $500 $0 May 22, 2014
Mar 31, 2014 35066292K RESOLVE CLASS - 1 WORK W/O A PERMIT ON 3/31/14 @ 2:00 P.M DURING PHYSICAL INSPECTION I OBSERVED 4 MAYTAG WASHERS HOT & COLD WATER LINES... $0 $0 Jun 26, 2014
Mar 31, 2014 35066294Y ACTIVE CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BLDG DEPT RECORDS DURING PHYSICAL INSPECTION I ... $12,000 $0 Jul 24, 2014
Sep 11, 2012 38222572X RESOLVE CLASS - 2 56Y10,56Y13,56B07,40Z10,52L02,05B01,67X10. 56Y- REPAIR & SEAL GLOW PACKING. 56B- ADD'L OIL IN MACHINE. 40Z- REPAIR M.... $0 $0 Dec 20, 2012
Dec 15, 2011 36017859H RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS: PERIODIC INSPECTION OF EXTER... $1,000 $0 Apr 12, 2012
Jan 25, 2011 36016079M RESOLVE CLASS - 2 FAILURE TO FILE AN ACCEPTABLE 6TH ROUND TECHNICAL REPORT IN COMPLIANCEW/CODE PROVISIONS:PERIODIC INSP OF EXTERIOR WAL... $8,000 $0 Jul 14, 2011
Mar 11, 2002 38121268Z ACTIVE Non-Hazardous 73X07/ 73-RESTORE DEVICE TO SERVICE SO A COMPLETE INSP CAN BE DONE BY THIS DEPT CALL 6462488732 WHEN READY $10,000 $0 Apr 25, 2002
Mar 11, 2002 38121267R ACTIVE Non-Hazardous 14M07/31Q07/62Q07/62K07/48R13/02L11/09H11/03I11/46R13/74D06/39H08/54T07/37B06/30O02/58O02/59O02/ 31-THRU OUT 62A,COVE... $10,000 $0 Apr 25, 2002
Feb 7, 2002 38121278M ACTIVE Non-Hazardous (1)B11/ (3)I11/ (3)M7/ (9)H12/ 15L11/ (16)H12/ (17)A12/ (17)Q3/(22)I11/ (23)U16/ 23P17/ (32)Q3/ (31)Q3/ (35)I11/ 35O2... $880 $0 Mar 28, 2002
Feb 7, 2002 38121277K ACTIVE Non-Hazardous 73X11/ 75U5/ 73X11 = MAKE REPAIRS & RESTORE TO SERVICE FOR A FULL INSPECTION BY THIS DEPARTMENT $880 $0 Mar 28, 2002
Sep 26, 2001 38119181N ACTIVE Hazardous 73D11/ 73L11/ 73X11 / 75B05 $2,500 $0 Nov 15, 2001
Sep 26, 2001 38119180L ACTIVE Non-Hazardous 9H12/ 17A12/ 17Q3/ 17I12/ 1B11/ 22I11/ <<<< SECONG OFFENCE 14I07/ 20X10/ 50D07/ 38X11/ 03B07/ 74#09 $2,500 $0 Nov 15, 2001
Aug 28, 2001 38118731Y ACTIVE Non-Hazardous 1B11-9H12-17A12-17Q3-22I11-22Y2-23U16-31Q3-32Q3-35I11-3M7-16H12-53X11-75U5 1B11=ALARM 17A12=MUST BE WIREGLASS(CAR) 17... $2,500 $0 Oct 18, 2001
Jul 24, 2001 38117673K ACTIVE Hazardous 7H12-17A12-17Q3-17I12-1B11-22I11-22Y2-25Q3-31Q3-35I11-23U16-50Y11-47B15-17M7 17A12=CAR 17Q3=CAR & ALL FLS 17I12=3 FL ... $500 $0 Apr 18, 2002
Jul 24, 2001 38117674M ACTIVE Non-Hazardous 50Y11-73X11-75U5 73X11=MAKE REPAIRS & RESTORE TO SERVICE FOR A FULL INSPECTION BY THIS DEPARTMENT $350 $0 Apr 18, 2002
Mar 16, 1999 34188879Z RESOLVE Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT: PERIODIC INSPECTIONOF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $10,000 $0 May 6, 1999
Dec 7, 1998 34188709X RESOLVE Non-Hazardous FAILURE TO SUBMIT A 4TH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OFEXTERIOR WALLS & APPURTENANCES AS REQUIRED BY L... $0 $0 Jun 3, 1999
Aug 31, 1998 34176735L RESOLVE Non-Hazardous FAILURE TO SUBMIT A 4TH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OFEXTERIOR WALLS & APPURTENANCES AS REQUIRED BY L... $0 $0 Jun 3, 1999
Jul 28, 1998 34156539X RESOLVE Hazardous FAILURE TO SUBMIT A FOURTH ROUND TECHNICAL REPORT: PERIODIC INSPECTIONOF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $0 $0 Jun 3, 1999
Dec 3, 1997 38067578J RESOLVE Non-Hazardous 73X 73-PROVIDE SERVICE TO ELEVATOR SO INSPECTION COULD BE DONE, $0 $0 Jun 3, 1999
Dec 3, 1997 38067579L ACTIVE Non-Hazardous 46L50Y50F06M57Z25D22D57O#M 46-CHANGE HOIST ROPES (50) SEAL MACHINE #50-REPAIR MACHINE CORRECT LOST MOTION 6-INSTALL G... $2,500 $0 Mar 12, 1998
Apr 28, 1997 34150948J RESOLVE Hazardous FAILRURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRE... $1,000 $0 Jun 3, 1999
Apr 26, 1996 34125070X RESOLVE Hazardous FAILURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT PERIODIC INSPECTION OF EXTERIOR WALLS AND APPUNTENANCES AS REQUIRED ... $5,000 $0 Jul 25, 1996
Jan 26, 1996 34116189Z RESOLVE Hazardous FAILURE TO SUBMIT A THRID ROUND TECHNICAL REPORT PERIODIE INSPECTION OF EXTERIOR WALL AND APARTENANCES AS REQUIRED BY... $1,000 $0 Jun 3, 1999
Nov 22, 1995 38052941N RESOLVE Non-Hazardous 35P,73X,57O. 73 RESTORE TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE BY THIS DEPT. $0 $0 Jun 3, 1999
May 13, 1994 34108071N RESOLVE Hazardous FAILURE TO SUBMIT A THIRD ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALL AND APPURTENANCES AS REQUIRED ... $400 $0 Jun 3, 1999
Mar 3, 1994 38040185Z RESOLVE Non-Hazardous 17M. VISION GUARDS. $0 $0 Jun 3, 1999
Jan 29, 1993 38017191J ACTIVE Non-Hazardous 14M,17I,0757O, 17. CAR PANEL CRACKED. $1,000 $0 Apr 8, 1993
Dec 23, 1991 34057410L RESOLVE Hazardous FAILURE TO SUBMIT A 2ND ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALL AND APPURTENANCES AS REQUIRED BY ... $0 $0 Jun 3, 1999
Nov 12, 1991 38019125K RESOLVE Non-Hazardous 73X, RESTORE ELEV TO SERVICE SO A COMPLETE INSP CAN BE MADE OR FILE WITH THIS DEPT. FOR REMOVAL. $0 $0 Jun 3, 1999
Feb 20, 1991 34052503H RESOLVE Non-Hazardous FAILURE TO MAINTAIN. STEEL FRAME STRUCTURE TO ROOF WATER TANK IS CRACKED CORRODED AND DEFECIVE AT VARIOUS LOCATIONS. ... $0 $0 Jun 3, 1999
Jan 18, 1991 38004414P RESOLVE Non-Hazardous 17M,28H,10L,18M,57O,74K,08V,#17 GRILLS #10 REPLACE BURN BUTTONS #18 COVERS #74 MOTOR ROOM ACCESS PLATFORM. $0 $0 Jun 3, 1999
Jan 8, 1991 38004415R RESOLVE Non-Hazardous 73X,15L,73O,#73 RESTORE ELEV TO SECURE FOR A COMPLETE INSPECTION CAN BE MADE BY THIS DEPT OR FILE WITH THIS DEPT.OR F... $0 $0 Jun 3, 1999