ECB violations
160 West 106 Street, Manhattan • Block 01860 • Lot 0061
33 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Nov 12, 2025 | 35720184R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO PROVIDE A NUMBER OF REQUIRED MEANS OF EGRESS FOR EV... | $2,500 | $2,500 | Mar 9, 2027 |
| Nov 12, 2025 | 35720183P | RESOLVE | CLASS - 2 | PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT-RESIDENTIALPURPOSES, DOB RECORDS INDICATES PREMISES TO BE ... | $2,500 | $2,500 | Mar 9, 2027 |
| Nov 12, 2025 | 35720186K | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLER SYSTEM WHERE REQUIRED ... | $2,500 | $2,500 | Mar 9, 2027 |
| Nov 12, 2025 | 35720185Z | RESOLVE | CLASS - 1 | BC 907.2.8. FAILURE TO PROVIDE A CLASS "J" FIRE ALARM SYSTEM FOR TRANSIENT USE AT #1A AT THE FIRST FLOOR. REMEDY: DIS... | $2,500 | $2,500 | Mar 9, 2027 |
| Oct 20, 2020 | 35542850K | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER(HANDICAP ACCESSIBILITY)(1101.3.2 REQUIREMENT BASED ON ALTERATIONS) ... | $625 | $525 | Oct 21, 2021 |
| Dec 1, 2015 | 35147802X | RESOLVE | CLASS - 2 | WORK W/O A PERMIT.NOTED:@ THE LOCATION 933 AMSTERDAM @ EXP#1 ILLUMINATED SIGN INSTALLED THAT(YEADS)"COSO APT RENTALS"... | $800 | $0 | Jan 21, 2016 |
| Dec 1, 2015 | 35147801Y | RESOLVE | CLASS - 2 | PERMIT HOLDER FAIL TO PROVIDE CCESS &/OR EXPOSE WORK ON ACTIVE SITE.NOTED:ONGOING CONST WORK ON EXISTING EATING & DRI... | $0 | $0 | Mar 31, 2016 |
| Nov 4, 2015 | 35164100X | RESOLVE | CLASS - 2 | PERMIT HOLDER FAIL TO PROVIDE ACCESS AND/OR EXPOSE WORK ON ACTIVE SITENOTED:PERMIT#140363112-01-EW-OT HOLDER DENIED A... | $0 | $0 | Dec 8, 2015 |
| Sep 4, 2013 | 35021735L | RESOLVE | CLASS - 2 | FAILURE TO PROVIE ARC-FAULT CIRCUIT INTERRUPTER (AFCI) PROTECTION IN DWELLING UNITS. APT 2D THROUGHOUT: NO ARC-FAULT ... | $2,400 | $0 | Oct 24, 2013 |
| Sep 4, 2013 | 35021736N | RESOLVE | CLASS - 1 | NO 2 CIRCUIT PROVIDED FOR COUNTERTOP/DINING/PANTRY/BREAKFAST AREA. THEKITCHEN APT 2D: NO 2 CIRCUIT PROVIDED (ON) THE ... | $800 | $0 | Oct 24, 2013 |
| Sep 4, 2013 | 35021738R | RESOLVE | CLASS - 1 | SEC. EC 406.11. TAMPER-RESISTANT RECEPTACLES IN DWELLING UNITS. IN ALLAREAS SPECIFIED IN 210.52, ALL 125-VOLT, 15 AND... | $800 | $0 | Oct 24, 2013 |
| Sep 4, 2013 | 35021734J | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE BLDG HALLWAYS: BRANCH CIRCUITWIRING, LIGHTING FIXTURES AND APT 2D, SUB PANEL... | $800 | $0 | Oct 24, 2013 |
| Sep 4, 2013 | 35021737P | RESOLVE | CLASS - 1 | SEC. EC 210.52(C1). NO RECEPTACLE OUTLETS PROVIDED EVERY 4'. KITCHEN COUNTERTOP APT 2D: NO RECEPTACLE OUTLETS PROVIDE... | $0 | $0 | Oct 24, 2013 |
| Apr 30, 2011 | 34904039K | RESOLVE | CLASS - 2 | MASONRY STONEWORK BAND AT 5TH FL EAST SIDE OF BLG A 8IN X 4IN PIECE FELL TO SIDEWALK DECORATIVE BAND WRAPS AROUND SID... | $500 | $0 | Jun 16, 2011 |
| Dec 17, 2007 | 38180482J | RESOLVE | Non-Hazardous | 84X10/41R9/5Q3/16M7/.84X-RESTORE CAR COMMUNICATIONS.41R-REMOVE BYPASS SWITCHES.5Q-PROVIDE GUARD OR WIRED GLASS FOR VI... | $180 | -$180 | Feb 14, 2008 |
| Oct 6, 2007 | 34605801N | RESOLVE | Hazardous | FAILURE TO PROVIDE NOTICE TO DOB PRIOR TO USE/INSTALL C-HOOKS IN CONNECTION W/SUSPENDED SCAFFOLD. | $500 | $0 | Jan 10, 2008 |
| Jan 27, 2007 | 34553564R | RESOLVE | Non-Hazardous | FAILURE TO MAINTAIN BLDG. EXHAUST FAN FOR EMPIRE CORNER RESTAURANT DEFECTIVE CAUSING VIBRATION TO UPPER FLS & NOISE. ... | $180 | -$180 | Mar 22, 2007 |
| Feb 1, 2005 | 38150742J | RESOLVE | Non-Hazardous | 83X07 83-COMPLETE MODERNIZATION OF ELEVATOR SO IT CAN BE TESTED BY DEPT OF BUILDINGS ELEV. INSPECTOR AND PROVIDE SERV... | $180 | $0 | Apr 21, 2005 |
| Oct 28, 2004 | 38149615Z | RESOLVE | Non-Hazardous | 83X10 83-REPAIR AND RESTORE TO SERVICE SO THAT A COMPLETE INSPECTION COULD BE CONDUCTED BY THIS DEPARTMENT. | $0 | $0 | Mar 10, 2005 |
| Oct 26, 2004 | 38149867P | RESOLVE | Non-Hazardous | 83X10 83) RETURN DEVICE #1P9144 TO SERVICE SO THAT A COMPLETE INSPECTION COULD BE CONDUCTED ON THE DEVICE BY THE DEPA... | $350 | -$350 | Mar 10, 2005 |
| Oct 4, 2004 | 38149602J | RESOLVE | Non-Hazardous | 83X10 83-REPAIR AND RESTORE TO SERVICE SO A FULL INSPECTION COULD BE DONE BY THE DEPARTMENT. | $350 | -$350 | Mar 10, 2005 |
| Sep 24, 2004 | 34443936L | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUIDLING IMPROPERLY INSTALLED ARE WINDOW UNIT ON 2ND FL ON THE NORTH ELEV DEBRIS & PLANTER THOUGH... | $2,000 | $0 | Mar 10, 2005 |
| Sep 3, 2004 | 38148789Y | RESOLVE | Non-Hazardous | 83X10.83-RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE. | $350 | $0 | Jul 14, 2005 |
| Jun 22, 2004 | 38148000H | RESOLVE | Non-Hazardous | 84##.84-REMOVING PARTS OF EXISTING ELEVATOR AND DELIVERING NEW MACHINE AND CONTROLLER FOR INSTALLATION WITHOUT PERMIT... | $500 | -$500 | Mar 10, 2005 |
| May 21, 2004 | 34433891H | RESOLVE | Hazardous | FAILURE TO MAINTAIN BLDG WALL.NOTE:(1)IMPROPERLY MOUNTED WINDOW A/C UNITS W/O METAL SUPPORT BRACKETS IN DANGER OF FAL... | $800 | $0 | Oct 28, 2004 |
| May 13, 2004 | 38147185Z | RESOLVE | Non-Hazardous | 83X10. 83-X-10-PUT ELEVATOR BACK IN FULL SERVICE TO BE INSPECTED BY A D.O.B ELEVATOR THE INSPECTED BY A D.O.B ELEVATO... | $0 | $0 | Jul 1, 2004 |
| Apr 2, 2003 | 38137141H | RESOLVE | Non-Hazardous | 37G10-52Y14-52Y2-59T16-54H12-11Q3-16B1-19B12-19B3-8V1-211B11-48BB13-50BB13-81BB5-30O2-31O2-36O2-62O2-63O2-64O2. 37-FU... | $0 | $0 | May 22, 2003 |
| Aug 25, 1998 | 38077150H | RESOLVE | Non-Hazardous | 73X-RESTORE ELEVATOR BACK TO SERVICE FOR COMPLETE INSPECTION BY THIS DEPARTMENT DOB. | $0 | $0 | Oct 15, 1998 |
| Dec 10, 1997 | 38067525X | RESOLVE | Non-Hazardous | 30O,20B,62K,11X,40P,35O,57O,14I,47H,58E,74#,61#,50Y,35H 14-GLASS MISSING FRAME 11-FIX CAR TOP LIGHTING 30-CLEAN CAR T... | $0 | $0 | Feb 5, 1998 |
| Dec 15, 1995 | 38053269Z | RESOLVE | Non-Hazardous | 15M,11R,18Q,35P,28L,46L,46T,48T,49T,61I,75T. 15M PUSH PLATES 17R SWIT-CH FOR WIRE GLASS 35P PROVIDE MEANS OF ACCESS I... | $500 | $0 | Apr 11, 1996 |
| Dec 23, 1994 | 38046668K | RESOLVE | Non-Hazardous | 11Q,36W,53M,35O,50Y,37G,17#,17R,18Q,10R,15M. 53-SWITCH AT ROOM. 17-AS PER CODE 17- SWITCH WIRE GLASS. 15-PUSH PLATE. | $0 | $0 | Mar 9, 1995 |
| Feb 24, 1994 | 38040181L | RESOLVE | Non-Hazardous | 10L,73O,17L,33P. 10 REPAIR TO HAVE CAR ANSWER CALLS PROPER. 17 INNER PANEL GLASS BROKEN. 33 LADDER TO OVERHEAR (REPAI... | $0 | $0 | Apr 21, 1994 |
| Jan 29, 1993 | 38017192L | RESOLVE | Non-Hazardous | 10B,33P,57O, 10. CAR STOOPS AT ALL FLOOR IN UP DIRECTION, 33. LADDER 15. SITUATED TOO FAR FRO OVERHEAD OPENING. | $0 | $0 | Apr 8, 1993 |