ECB violations
229-239 West 99 Street, Manhattan • Block 01871 • Lot 0020
18 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 19, 2024 | 39109267L | RESOLVE | CLASS - 2 | OBSERVED IN THE BASEMENT IN THE ELEVATOR EQUIPMENT ROOM GAS LINE INSTALLED WHICH CONTRARY TO NYC ELEVATOR CODE APPEND... | $0 | $0 | Mar 10, 2025 |
| Jul 22, 2021 | 35479461H | RESOLVE | CLASS - 1 | SCAFFOLD DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS CD5.AT TIME OF INSPECTION OBSERVED SCAFFOLDS IN USE AT E... | $625 | $0 | Feb 16, 2023 |
| Apr 30, 2021 | 35556224K | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE AN DOR HAVE SITE SAFETY MANAGER OR SITE SFATEY COORDINATOR PRESENT AT SITE AS REQUIRED NOTED AT ... | $10,000 | $0 | May 12, 2022 |
| Apr 30, 2021 | 35556223Z | RESOLVE | CLASS - 1 | WORK DOES NOT COFNROM TO APPROVED CONSTRUCTION DOCUMENTS AND OR APPROVED AMENDMENTS SITE SFAETY PLAN NOTED AT THE TIM... | $2,500 | $0 | May 12, 2022 |
| Apr 9, 2021 | 38273882L | RESOLVE | CLASS - 2 | 40R9: 40-R-9 = ILLEGAL GAS AND WATER LINES RUNNING THROUGH MACHINE ROOM. REMEDY MUST REMOVE OR RE-ROUTE OUTSIDE MACHI... | $0 | -$625 | Mar 18, 2024 |
| Apr 2, 2021 | 35537488K | RESOLVE | CLASS - 2 | FAILURE TO DISTRIBUTE OR POST SAFE CONSTRUCTION BILL OF RIGHTS. AT TIME OF INSPECTION I SPOKE W/ THE BUILDING MAINTEN... | $1,250 | $0 | May 12, 2022 |
| Jan 17, 2020 | 39015959P | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION I OBSERVED APPROX. 12" LONG SHEET METAL LOOSE, FLAPPING WITH WIND OUTSIDE OF BATHROOM WINDOW IN... | $0 | $0 | Mar 5, 2020 |
| May 21, 2019 | 35254391Y | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCESSOUTH ELEVATION EXP1: A/C SUPPORTED BY BRICK AT ... | $620 | $0 | Jul 25, 2019 |
| Nov 28, 2011 | 34933888H | RESOLVE | CLASS - 2 | FAILURE TO POST PERMIT AT JOB-SITE UPON INSPECTION AS NOTED ON ACTIVE ALRERATION SITE WHERE WORKER'S ARE PREPARING EX... | $0 | $0 | Jan 12, 2012 |
| Aug 10, 2010 | 34852283K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. DEFECTS NOTED: AT TIME OF INSPECTION THERE IS WATER DAMAGE E... | $500 | $0 | Mar 31, 2011 |
| Feb 11, 2010 | 34817368X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED: C RACK APPROX 3 FT LONG IN CLOTHES CLOSET,IN HALLWAY NEA... | $500 | $0 | Apr 8, 2010 |
| Sep 1, 2005 | 34490176J | RESOLVE | Non-Hazardous | FAILURE TO PROTECT ROOFS, ROOF OUTLETS OR SKYLIGHTS OF ADJOINING PROPERTY DURING CONSTRUCTION OPERATIONS. NOTED: ON G... | $0 | $0 | Feb 9, 2006 |
| Sep 1, 2005 | 34484100M | RESOLVE | Non-Hazardous | SIDEWALK SHED DOES NOT MEET BLDG CODE SPECIFICATIONS-NOT EXTENDED 20' FOR BLDG MORE THAN 100' IN HEIGHT. NOTED: SIDEW... | $0 | $0 | Feb 9, 2006 |
| Mar 28, 2003 | 34384462L | RESOLVE | Non-Hazardous | FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT: PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... | $0 | $0 | Jul 3, 2003 |
| Mar 20, 2003 | 38136696R | RESOLVE | Non-Hazardous | 24U16-17H12-34I12-81U5. 24-U-16 5 YEAR TAG 17-H-12 1,5,6 & 15 FLOORS. 34-I-12 TOP STEP. | $0 | $0 | May 8, 2003 |
| Jul 18, 2002 | 38124437Y | RESOLVE | Non-Hazardous | 50U16-15L11-32Q3-33P17-57O2-23U16. 50-U-16 CITY I.D 15-L-11 NOT SELF CLOSING 21 ST FL. 52-Q-3 BETWEEN BSMT & 1 ST FL ... | $0 | $0 | Sep 5, 2002 |
| Jul 5, 2002 | 38124214R | RESOLVE | Non-Hazardous | 30I11/ 33P17/ 57O2/ 74B7/ 30I11 = HOLE TOP FL COUNTER WEIGHT SIDE 74B7 = POST CERTIFCATE IN CAR AS PER CODE 27-1004(A... | $180 | $0 | Aug 22, 2002 |
| Feb 6, 1993 | 38031129J | RESOLVE | Non-Hazardous | 35I 73U 74R 35 PATCH HOLES IN MOTOR ROOM FLOOR 73 PROPERLY SECURE 74 REMOVE ENTIRELY EMERGENCY RELEASE SWITCHES | $0 | $0 | Apr 15, 1993 |