ECB violations
251-259 West 104 Street, Manhattan • Block 01876 • Lot 0001
20 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 24, 2019 | 35365567K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES SOUTH EELVATION EXPOSURE 1 OBSERVED REOPENING CRACKS A... | $0 | $0 | Aug 22, 2019 |
| Feb 14, 2018 | 37006787K | RESOLVE | CLASS - 1 | BC3307.6.4:DEFICIENT DESIGN-THE RESPONDENT,DESIGN APPLICANT,FAILED TO MEET THE REQS OF BC3307.6.4 AND BC1604.2 IN A H... | $0 | $0 | Dec 27, 2018 |
| Dec 20, 2017 | 35310378N | RESOLVE | CLASS - 2 | SEC: BC 3307.6.5.7. INSTALLATION INSP. NOTE: OBSERVED SIDEWALK SHED IS IN PLACE. FAILURE TO PROVIDE AN INSTALLATION I... | $400 | $0 | Feb 22, 2018 |
| Dec 1, 2017 | 35295672L | RESOLVE | CLASS - 2 | SIDEWALK SHED DOES NOT CONFORM TO APPROVED PLANS. NOTED: AT TIME OF INSPECTION CROSS BRACES FOR THE SIDEWALK SHED ARE... | $0 | $0 | Jan 18, 2018 |
| Sep 25, 2015 | 38239025H | RESOLVE | CLASS - 2 | 02B10,16M07,17D06,03B10,34O02,42N09,42B06,56Y13,70Y02,71X10. 16M-PROVIDE SITEGUARD ON HOISTWAY DOORS AS PER CODE; 02B... | $2,500 | $0 | Dec 3, 2015 |
| May 13, 2014 | 35074179Z | RESOLVE | CLASS - 3 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER.DEFECTS NOTE:@ APT 7F.(1)LOOSE CERAMIC WALL TILES IN BATHROOM NEAR ... | $0 | $0 | Jul 3, 2014 |
| Sep 18, 2012 | 34997249Y | RESOLVE | CLASS - 1 | ALL DISCONNECT SHALL BE GROUNDED IN ONE LOCATION. 400 AMP SERVICE DISCONNECT IN THE (SUPER SHOP), NOT GROUPED. REM: C... | $1,000 | $0 | Feb 27, 2013 |
| Nov 16, 2011 | 32071482Z | RESOLVE | CLASS - 2 | B254,15,16,21A,21A,32A,42,46B,50A-HEV-E OILBURNER,LPSTM BOILER-MISSINGPULLY GUARD @ TRANSFER PUMP, COMPLY TO CODE REP... | $250 | $0 | Feb 9, 2012 |
| Jan 12, 2006 | 34505756P | RESOLVE | Non-Hazardous | WORK W/O APERMIT:EXPIRED PERMIT.PERMIT #104221691 FOR SIDEWALK SHED EXPIRED 12/16/05.NOTED LOCATION:SOUTH & WEST FACA... | $0 | $0 | Mar 2, 2006 |
| Jan 12, 2006 | 34505757R | RESOLVE | Non-Hazardous | DANGEROUS PLACES & SPACES.NOTED DEFECTS.(1)INSTALLATION OF BARBED WIRING AT TOP OF PARAPET WALL(WOODEN)OF SIDEWALK SH... | $0 | $0 | Mar 2, 2006 |
| Dec 23, 2002 | 38135437H | RESOLVE | Non-Hazardous | 80##. 80 - FAILURE TO REPORT ACCIDENT PROMPTLY AS PER RULE 27-1006 ACCIDENT OCCURED 08/18/02 ACCIDENT REPORTED 12/23/02. | $0 | $0 | Feb 6, 2003 |
| Dec 20, 2002 | 38133949M | RESOLVE | Non-Hazardous | 80X11-48B15. 80-REPAIR COMMUNICATIOR OUT OF ORDER (TELEPHONE) 48-PROVIDE PROPER CLEARUNCE TO CTW BUFFER. | $0 | $0 | Feb 6, 2003 |
| Dec 19, 2002 | 38133948K | RESOLVE | Non-Hazardous | 81U16-80X11-48B15. 80-REPAIR COMMUNVCATION OUT OF ORDER (TELEPHONE) 48-PRIVIDE PROPER CLEAROUCE TO CTIC BUFFER. | $0 | $0 | Feb 6, 2003 |
| Mar 7, 2000 | 38095589N | RESOLVE | Non-Hazardous | 35B09/30002 H35-B-09 REMOVE OLD PARTS FROM MACHINE ROOM. | $350 | $0 | Apr 28, 2000 |
| Mar 7, 2000 | 38095588L | RESOLVE | Non-Hazardous | 30002/06Q07/61B01 H06-0-07 COVER WIRES ON GATESWITCH #61-B-01TIGHT TEN CABLE. | $350 | $0 | Apr 28, 2000 |
| Mar 7, 2000 | 38095586H | RESOLVE | Non-Hazardous | 46H15/74M07/50Y14/35002/30002 #74-M-07 PROVIDE SPRING FOR C.W.T. | $350 | $0 | Apr 28, 2000 |
| Mar 7, 2000 | 38095587J | RESOLVE | Non-Hazardous | 50Y14/35002/30002 | $350 | $0 | Apr 28, 2000 |
| Nov 10, 1997 | 38065103R | RESOLVE | Non-Hazardous | 47L31D57Z30O35I36T32D50Y #47 EXCESSIVE HIBE ON CABEL #31 UNDERE PLATFORM #32 SECURE WIRES HANGING OFF PIPE ON WALL. | $0 | $0 | Jan 15, 1998 |
| Sep 10, 1993 | 38037227K | RESOLVE | Non-Hazardous | 57O 62O 62I 62 62 SECURE WIRING | $0 | $0 | Nov 18, 1993 |
| Sep 10, 1993 | 38037226Z | RESOLVE | Non-Hazardous | 64B,50O,62O,62D. | $0 | $0 | Nov 18, 1993 |