Skip to content

ECB violations

300-304 West 97 Street, Manhattan • Block 01887 • Lot 0022

30 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Jun 11, 2024 39529490P RESOLVE CLASS - 2 I OBSERVED PEDESTRIAN PROTECTION (SIDEWALK SHED) INSTALLED AT EXPOSURE 1 CONTRARY TO CODE 3307.6.4.9-AVOID INTERFEREN... $2,400 $2,400 Feb 12, 2026
Jun 11, 2024 39529488X RESOLVE CLASS - 2 UPON INSPECTION OF A 15 STORY FACADE ALT CONSTRUCTION SITE I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOSURES 1&4 WITH... $1,250 $0 Aug 15, 2024
Jun 15, 2022 39064317Y RESOLVE CLASS - 2 BOILERS 8' OR ABOVE MUST HAVE WELDED LADDER AND PLATFORM, LIGHTS ABOVE BOILER NOT WORKING CORRECT ALL VIOLATING CONDI... $310 $0 Aug 4, 2022
Feb 21, 2020 35479526J RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS & OR APPROVEDAMENDMENTS(CD5)NOTE: AT TIME OF INSPECTION OF A... $2,500 $0 Oct 28, 2021
Feb 21, 2020 35479529P RESOLVE CLASS - 1 FAILURE TO PROTECT LINELINES FROM SHARP EDGES & ABRASION CAUSING A HAZARDOUS CONDITION FOR WORKERS. NOTE: AT TIME OF ... $2,500 $0 Oct 28, 2021
Feb 21, 2020 35470149M RESOLVE CLASS - 2 FAILURE TO POST OR DISTRIBUTE,SAFE CONSTRUCTION BILL OF RIGHTS. NOTE: FAILURE TO POST SAFE CONSTRUCTION BILL OF RIGHT... $0 $0 Apr 30, 2020
Feb 21, 2020 35479531Y RESOLVE CLASS - 1 SEC. 3301.1.3 MANUFACTURER SPECIFICATIONS. NOTE: AT TIME OF INSPECTIONOF A 15 STY BLDG FACADE WORK IN PROGRESS,I OBSE... $625 $0 Mar 24, 2022
Feb 21, 2020 35479525H RESOLVE CLASS - 2 SEC. 3314.4.15 PARTIAL STOP WORK ORDER ISSUED FOR ALL EXTERIOR WORK PURSUANT TO 28-207.2 & POSTED AT PREMISES(NO NOTI... $1,250 $0 Oct 28, 2021
Feb 21, 2020 35479530M RESOLVE CLASS - 1 SEC. 3314.10.9 IMPROPER INSTALLATION OF TIEBACK PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD & ALL FACADE WORK ISSU... $0 $0 Oct 28, 2021
Feb 21, 2020 35470148K RESOLVE CLASS - 2 FAILURE TO POST OR DISTRIBUTE NOTICE OF TENANT PROTECTION. NOTE: AT TIME OF INSPECTION,I OBSERVED NO TENANT PROTECTIO... $0 $0 Apr 30, 2020
Feb 21, 2020 35470144N RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS & OR APPROVEDAMENDMENTS(SSP). NOTE: AT TIME OF INSPECTION,I ... $625 $0 Aug 26, 2021
Feb 21, 2020 35470145P RESOLVE CLASS - 1 SEC. 3309.14 FAILURE TO PROTECT ADJOINING PROPERTY DURING CONSTRUCTIONOPERATIONS. NOTE: AT TIME OF INSPECTOIN OF A 15... $625 $0 Aug 26, 2021
Feb 21, 2020 35470146R RESOLVE CLASS - 2 SEC. 3309.10 PROTECTION OF ROOFS(SKYLIGHT,WINDOWS)NOTE: AT THE TIME OFINSPECTION,I WAS ON THE ROOF OF(JOB#123140779)S... $625 $0 Aug 26, 2021
Feb 21, 2020 35470147Z RESOLVE CLASS - 1 PRESENCE AT SITE. NOTE: AT THE TIME OF INSPECTION OF(JOB#123140779)AN ALTERATION OF A 15 STY BLDG,WAS ABLE TO GAIN AC... $0 $0 Aug 26, 2021
Feb 21, 2020 35479527L RESOLVE CLASS - 1 SEC. 3314.3.1.1 PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD & ALL FACADE WORKER PURSUANT TO 28-207.2 & POSTED AT P... $250 $0 Aug 4, 2022
Feb 21, 2020 35479528N RESOLVE CLASS - 1 SEC. 3314.15.2 PARTIAL STOP WORK ORDER FOR SUSPENDED SCAFFOLD ISSUED PURSUANT TO 28-207.2. TO ALL FACADE WORK(EXTERIO... $625 $0 Aug 4, 2022
Nov 22, 2019 35461606Y RESOLVE CLASS - 1 UNSAFE STORAGE OF COMBUSTINLE NOTED AT THE TIM EOF MY INSPECTION ON ANACTIEV JOBSIET I OBSERVED 1 FLAMMABLE CANISTER ... $2,500 $0 Dec 3, 2020
Nov 22, 2019 35461605M RESOLVE CLASS - 1 WORK CONTRARY TO APPROVED CONSTRUCTION DOCUMENTS NOTED AT THE TIME OF MY INSPECTION OF THE SITE SFATEY PLAN I DISCOVE... $2,500 $0 Dec 3, 2020
Jun 13, 2018 35324085R RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE: AT TIMEOF INSPECTION,I BSERVED SIDEWALK SHED IN PLACE ... $1,280 $0 Aug 2, 2018
May 19, 2008 34610349M ACTIVE Non-Hazardous FAILURE TO PROVIDE DRIP VALVES BETWEEN SIAMESE CONNECTION AND CHECK VALVE. ON INSPECTION DAY: 05/19/08, IN THE BASEME... $400 $0 Aug 5, 2010
May 19, 2008 34653025X ACTIVE Hazardous FAILURE TO MAINTAIN PLUMBING AND/OR APPURTENANCES-HAZARDOUS. IN THE BASEMENT OF THE BUILDING TWO COMMERCIAL COIN OPER... $800 $0 Jul 10, 2008
Oct 6, 2007 34605803R RESOLVE Hazardous FAILURE TO NOTIFY DOB PRIOR TO USE/INSTALL C-HOOKS IN CONNECTION W/SUSPENDED SCAFFOLDS. $500 -$500 Jan 10, 2008
Jun 8, 2006 32051756Z RESOLVE Non-Hazardous CEASE USE 3-B, 51,50A,50B,42,50C,50D,7A,50E,50F. 50A-ADJUST OIL BURNER, OBSERVED BURNER FAILURE GOING INTO HIGH & LOW... $800 $0 Nov 2, 2006
Mar 12, 2003 38136679P RESOLVE Non-Hazardous 12Q3-3M7-19Q3-24U16-39M7-79O2-16L11. 3-M-7 CAPACITY PLATE 19-Q-3 16 FT 24-U-16 5 YEAR TAG 39-M-7 CORRECT FUSE AMPRAGE... $0 $0 May 1, 2003
Oct 27, 1998 38080271L RESOLVE Non-Hazardous 22D6,30O2,62O2,3O2,47#12. 22-LOCK FROM TOP. 30-CLEAN DOWN (62-03). 47-REPLACE WORN, DEFECTIVE GOV ROPE. $0 $0 Dec 17, 1998
Oct 27, 1998 38080272N RESOLVE Non-Hazardous 18D6,27I11,30O2,62O2,3O2,1X12. 18-SECURE BSMT DOOR LOCK & COVER. 27-REPAIR FINAL LIMIT. 30-CLEAN DOWN. 1-REPAIR & REP... $0 $0 Dec 17, 1998
Oct 19, 1990 34049256M RESOLVE Hazardous FAILURE TO PROVIDE TOE BOARD ON A TWO POINT SUSPENSION SCAFFOLD CORRECTION PROVIDE TOW BOARD STIRRUPS APROX 4 FT FROM... $3,730 $0 Jan 3, 1991
Oct 19, 1990 34049255K RESOLVE Hazardous USE OF A TWO POINT SUSPENSION SCAFFOLD WITHOUT A SPECIAL RIGGERS LICENSE CORRECTION OBTAIN LIENSE TWO POINT SUSPENSIO... $12,920 $0 Jan 3, 1991
Oct 18, 1990 34049253R ACTIVE Hazardous USE OF A SUSPENSION SCAFFOLD WITHOUT A SPECIAL RIGGERS LICENSE CORRECTION OBTAIN LICENSE THREE WORKERS ON ONE SCAFOLD... $11,500 $0 Nov 30, 1990
Oct 18, 1990 34049254Z RESOLVE Hazardous OPERATION OF TWO POINT SUSPENSION SCAFFOLD IN AN UNSAFE MANNER BY OPERATING MATERIAL HOIST ATTACHED TO SCAFFOD CORREC... $4,945 $0 Jan 3, 1991