Skip to content

ECB violations

605-609 West 114 Street, Manhattan • Block 01896 • Lot 0014

19 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
May 30, 2023 39087286M RESOLVE CLASS - 2 WORK WITHOUT A PERMIT. FULL HEIGHT PARTITIONS HAVE BEEN ERECTED AND DEMOLISHED IN APT #'S 55 AND 54 WHICH HAS RESULTE... $1,250 $0 Jun 6, 2024
Jan 22, 2021 35526632M RESOLVE CLASS - 1 FAILURE TO COMPLY W/ COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39017879Y ISSUED 2/19/20&TO FILE CERTIFICATE... $0 $0 Apr 8, 2021
Nov 23, 2020 35524175R RESOLVE CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39017879Y ISSUED ON 02/19/20 & TO FILE A CERT OF CORREC... $0 $0 Feb 4, 2021
Sep 25, 2020 35521190L RESOLVE CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #39017879Y ISSUED ON 02-19-20 AND TO FI... $0 $0 May 6, 2021
Sep 25, 2020 35521562N RESOLVE CLASS - 1 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39017875R ISSUED ON 02/19/20 & TO FILE A CERT OF CORREC... $1,250 $0 Dec 31, 2020
Feb 20, 2020 39018012X RESOLVE CLASS - 1 GAS BEING SUPPLIED TO BUILDING WITHOUT INSPECTION AND CERTIFICATION BY DOB I OBSERVED IN CELLAR IN THE LAUNDRY ROOM S... $5,000 $0 Apr 22, 2021
Feb 19, 2020 39017879Y RESOLVE CLASS - 1 WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, OBSERVED 4 GAS DRYERS, AND 5 WASHING MACHINES IN STALLED IN THE CELLAR ... $0 $0 Jan 14, 2021
Feb 19, 2020 39017875R RESOLVE CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED 4 GAS DRYERS IN THE LAUNDRY RO... $1,250 $0 Oct 29, 2020
Jul 18, 2019 35439880X RESOLVE CLASS - 1 SEC. 3314.4 INSTALLATION. AT TIME OF INSPECTION OBSERVED OUTRIGGER & TIEBACK CLAMPS ON PARAPET FOR SUPENDED SCAFFOLD.... $2,500 $0 Dec 5, 2019
Feb 6, 2018 38261333K RESOLVE CLASS - 1 97X17 THE ONLY ELEVATOR IN BLDG OR SECTION OF BUILDING OUT OF SERVICEUPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF... $2,500 $0 Sep 19, 2019
Dec 22, 2017 37007159Y RESOLVE CLASS - 1 FILED A CERTIFICATE FORM, APPLICATION ETC., CONTAINING A MATERIAL FALSE STATEMENT(S). NOTED: THE OWNER/REPRESENTATIVE... $2,400 $0 Feb 8, 2018
Dec 22, 2017 37007158M RESOLVE CLASS - 1 FILED A CERTIFICATE FORM, APPLICATION ETC., CONTAINING A MATERIAL FALSE STATEMENT(S). NOTED: THE OWNER/REPRESENTATIVE... $4,800 $0 Mar 1, 2018
Aug 30, 2016 35180672L RESOLVE CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.INSPECTION TIME 3PM AT ABOVE DATE. AT TIME OF INSPECTI... $0 $0 Dec 8, 2016
May 13, 2016 35182005R RESOLVE CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. AT TIME OF INSPECTION (12:30PM) ... $1,000 $0 Dec 15, 2016
Mar 16, 2005 38151778X RESOLVE Non-Hazardous 84L10 #84-L-10 REPAIR EMERGENCY PHONE SYSTEM. $0 $0 May 5, 2005
Apr 18, 2003 34384805Y RESOLVE Non-Hazardous FAILURE TO SUMBMIT A FIFTH ROUND TECHNICAL REPORT PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $0 $0 Apr 1, 2004
Dec 27, 2000 34260466Y RESOLVE Hazardous NO TOE BOARD ON A TWO POINT SUPENDED SCAFFOLD.OPERATION OF HOISTING EQUIPMENT IN AN UNSAFE MANNER(1)NO FILING FOR THE... $4,750 $0 Aug 9, 2001
Jun 18, 1997 38059286H RESOLVE Non-Hazardous 46T49T 46-49 RESSOCHET HOIST & DRUM CWT. CABLES $0 $0 Aug 7, 1997
Mar 9, 1989 34020458L RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL HAZARDOUS SPALLING BRICKWORK ND CEMENT PARGING AT FRONT PARAPET LEVEL ABOV... $625 $0 May 11, 1989