145 West 126 Street, Manhattan
Manhattan • Block 01911 • Lot 0014 • Zip: 10027
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 7 days ago- Times Square 27 min 7 walking, 20 riding
- Penn Station 29 min 7 walking, 22 riding
- Grand Central 35 min 7 walking, 28 riding
- Union Square 40 min 7 walking, 33 riding
- Fulton Street 41 min 7 walking, 34 riding
- Downtown Brooklyn 46 min 7 walking, 39 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Red Rooster
Red Rooster is a vibrant and soulful restaurant located in the heart of Harlem. Known for its modern take on classic ...
Sylvia's Restaurant
Sylvia's Restaurant is a beloved soul food spot in Harlem, known for its comforting classics like fried chicken and c...
Harlem Shake
Harlem Shake is a vibrant, eclectic restaurant in the heart of Harlem. Known for its delicious burgers, shakes, and c...
Settepani
No description yet
Vinateria
No description yet
Harlem Hops
No description yet
Africa Kine Restaurant
No description yet
Sottocasa Pizzeria - Harlem
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2025
-
DOB violation Nov 14, 2025
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
2024
-
DOB violation Sep 23, 2024
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
2023
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 30, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
-
DOB violation Jun 20, 2023
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
2019
-
HPD violation Oct 25, 2019
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2018
-
HPD violation Oct 10, 2018
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2017
-
HPD violation Nov 9, 2017
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2016
-
HPD violation Nov 28, 2016
Class B
§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP...
-
CLASS - 1
UNQUALIFIED WORKER PERFORMING WORK ON SUPPORTED SCAFFOLD. NOTED: AT TIME OF INSPECTION FOLLOWING WORKER: SALH UDDEN W...
-
CLASS - 1
SEC. 3314.4.2.2 NO COMPETENT PERSON FOR SUPPORTED SCAFFOLD ON SITE. NOTED: AT TIME OF INSPECTION SUPPORTED SCAFFOLD A...
-
CLASS - 1
SEC. 3314.4.3.1 FAILED TO PROVIDE INSTALLATION INSPECTION REPORT. NOTED: AT TIME OF INSPECTION SUPPORTED SCAFFOLD THA...
-
CLASS - 1
SEC. 3314.1 PARTIAL SWO ISSUED FOR SUPPORTED SCAFFOLD PURSUANT 28-207.2 & POSTED ON PREMISES. SUPPORTED SCAFFOLD DOES...
-
Alteration Type III
-
Alteration Type II
2015
-
HPD violation Oct 2, 2015
Class I
§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27...
2014
-
Alteration Type III
INSTALLATION OF 25 LF SIDEWALK SHED AS PER PLAN. NO CHANGE IN USE EGRESS OR OCCUPANCY.
-
Alteration Type II
-
Alteration Type III
ERECT HEAVY DUTY SIDEWALK SHED PER DRAWINGS. INSTALLATION SHALL COMPLY WITH BSA-351-74-SM, LL-33/91, CHAPTER 33, SECT...
2013
-
HPD violation Nov 26, 2013
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FRAME OF DOOR, IN THE ENTRANCE LOCATED AT APT 4B, 4th...
-
CLASS - 2
FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A C/C W/THE DOB FOR NOV #34940564R ISSUED ON 11.26.12 PURSUANT T...
2012
-
CLASS - 1
FAILURE TO MAINTAIN BLDG WALLS &/OR APPURTENANCES. NOTED: AT FRONT FACADE. 3RD FL EXPOSURE 1 ORNAMENTAL STONE WORK AR...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources