ECB violations
2450-2454 8 Avenue, Manhattan • Block 01937 • Lot 0001
54 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 30, 2026 | 39186805Z | RESOLVE | CLASS - 2 | MISALINGED CAB MIRROR (NYC BUILDING CODE). INOPERATIVE TOP OF CAR LIGHT (2.26). PROIVDE READILY AVAILABLE KEYS TO BAS... | $0 | $0 | Aug 27, 2026 |
| Sep 24, 2025 | 39161441X | RESOLVE | CLASS - 1 | CLASS 1 CEASE USE ITEMS;; INOPERATIVE T.O.C. BOX-FIX. INOPERATIVE DOOR ZONE LOCK-ADJUST. MALFUNTIONING DOOR OPERATOR.... | $3,125 | $3,125 | Jan 5, 2027 |
| Aug 18, 2025 | 39157385Z | RESOLVE | CLASS - 1 | CLASS 1: UPON INSPECTION FOUND DEVICE OUT OF SERVICE. RESTORE TO SERVICE, REPAIR IMMEDIATLY AS PER 1RCNY 11-02. | $1,250 | $1,250 | Dec 4, 2025 |
| Jul 25, 2025 | 35718332R | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES. AS NOTED: AT THE TIME OF INSPECTION I OBSERVED ON EXPO... | $5,000 | $5,000 | May 28, 2026 |
| Apr 21, 2025 | 39145483Y | RESOLVE | CLASS - 2 | CLASS 2: PHONE INOPERATIVE REPAIR AND CONNECT SERVICE TO 24 HR EMERGENCY OPERATOR. CAR DOOR MISALIGNED ADJUST TO REMO... | $625 | $625 | Jul 31, 2025 |
| Jan 29, 2025 | 35689876P | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING EXTERIOR FACADE AND APPURTENANCES IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION IT WAS... | $625 | $625 | Apr 10, 2025 |
| Nov 22, 2024 | 35686989H | RESOLVE | CLASS - 1 | UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. NOTE: AT TIME OF INSPECTION, RESPONDENT HAS FAILED TO... | $0 | $0 | Jan 30, 2025 |
| Oct 28, 2024 | 39128604R | RESOLVE | CLASS - 1 | CLASS 1: UPON INSPECTION FOUND DEVICE TO BE OUT OF SERVICE. THIS PRESENTS A SSAFETY HAZZARD TO RESIDENTS & FIRST RESP... | $1,250 | $1,250 | Jan 2, 2025 |
| Jul 23, 2024 | 35683691L | RESOLVE | CLASS - 1 | UNLAWFUL ACTS.FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER.NOTE:AT TIME OF INSPECTION,RESPONDENT HAS FAILED TO COM... | $0 | $0 | Dec 2, 2024 |
| Jul 23, 2024 | 35683692N | RESOLVE | CLASS - 1 | FILED A CERTIFICATE OF CORRECTION OR OTHER RELATED MATERIALS CONTAINING MATERIAL FALSE STATEMENTS.ON 7/10/2024 RESPON... | $0 | $0 | Dec 2, 2024 |
| May 14, 2024 | 35682072H | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE AT TIME OF INSPECTION OBSERVED BROKEN WINDOW 2 S... | $2,500 | $2,500 | Feb 6, 2025 |
| May 14, 2024 | 39114278N | ACTIVE | CLASS - 2 | SPRINKLER INSTALLATION NOT IN ACCORDANCE WITH CODE ON 07/02/2020 AT APPROX 8:40AM I OBSERVED A SPRINKLER SYSTEM INSTA... | $1,250 | $1,250 | Jan 16, 2025 |
| May 14, 2024 | 39114277L | ACTIVE | CLASS - 2 | I OBSERVED IN 7TH FLOOR LAUNDRY ROOM NEWLY INSTALLED WATER PIPING, VALVES, GAUGES, AND SPRINKLER HEADS FOR SEVERAL CO... | $1,250 | $1,250 | Jan 16, 2025 |
| May 14, 2024 | 39114382N | RESOLVE | CLASS - 1 | I OBSERVED ON 7TH FLOOR COMMERCIAL GAS DRYERS INSTALLED WITH GAS PIPING AND VENTS AND VIOLATION 34932268M WAS ISSUED ... | $0 | $0 | Dec 3, 2024 |
| Apr 25, 2023 | 39084607K | RESOLVE | CLASS - 2 | CLASS 2: PHONE INOPERATIVE REPAIR & PROGRAM TO 24 HR OPERATOR. DOOR OPERATOR MISALIGNED. ADJUST TO FULLY OPEN DOOR. M... | $0 | $0 | Jun 29, 2023 |
| Oct 19, 2022 | 37022786Z | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $3,125 | $3,125 | May 11, 2023 |
| Aug 1, 2022 | 39504384K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF NB CLOSED SITE OBSERVED CONSTRUCTION FENCE NOT AS PER CODE, CONSTRUCTION FENCE AT EXP1 PAINT... | $0 | $0 | Sep 15, 2022 |
| Jun 13, 2022 | 39502157L | RESOLVE | CLASS - 2 | NO SAFE MEANS OF EGRESS-EXCAVATION I OBSERVED ACTIVE SITE AT EXCAVATION PHASE WITH 3 WORKERS PREPARING FOOTING AT APP... | $0 | $0 | Jul 28, 2022 |
| Apr 7, 2022 | 39059761Y | RESOLVE | CLASS - 1 | CLASS 1 RESTORE TO SERVICE FOR PROPER INSPECTION BY D/O/B. | $1,250 | $0 | Jul 28, 2022 |
| Mar 31, 2022 | 39059236X | RESOLVE | CLASS - 1 | CLASS 1 RESTORE TO SERVICE FOR PROPER INSPECTION BY D/O/B. | $3,125 | -$3,125 | Jul 14, 2022 |
| Feb 3, 2022 | 39055506Z | RESOLVE | CLASS - 2 | FOUND WIRE JUMPER USED ON ONE FUSE IN THE ELRVATOR CONTROLLER IN THE ELEVATOR MACHINE ROOM. REMOVE WIRE JUMPER AND RE... | $0 | $0 | Mar 24, 2022 |
| Sep 10, 2021 | 39047304K | RESOLVE | CLASS - 1 | FOUND DOOR LOCK MONITORING IS NOT WORKING. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APP... | $3,125 | $0 | Mar 31, 2022 |
| Jun 1, 2021 | 37021322X | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WA... | $3,125 | $0 | Apr 21, 2022 |
| Dec 23, 2020 | 39033885K | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY : INSTAL... | $1,250 | $0 | Feb 11, 2021 |
| Apr 9, 2020 | 39020861N | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | May 28, 2020 |
| Oct 15, 2018 | 37012923R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $1,250 | $0 | Mar 7, 2019 |
| Jan 16, 2018 | 38260780H | RESOLVE | CLASS - 2 | 39O09,41M07,60X10. 41M-DOOR LOCK; 39O-REMOVE DIRTY RAGS. | $250 | $0 | Mar 8, 2018 |
| Mar 1, 2017 | 35226362R | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. NOTED: WORK BEING DONE AS PER PE... | $0 | $0 | May 5, 2017 |
| Jan 23, 2017 | 38252563L | RESOLVE | CLASS - 2 | 45L10,5X1. GOVERNOR IS MAKING A LOUD BANGING NOISE AS ELEVATOR RUN. DOOR RESTRICTOR IS INOPERATIVE. | $0 | $0 | Mar 9, 2017 |
| Jan 12, 2017 | 38252725P | RESOLVE | CLASS - 1 | CEASE USE. 45L10,45T07,42N11,69B07,05X10,15M07,16T07. (45L)GOVERNOR DOES NOT TRIP @ SPEED ACCORDING TO ELEVATOR CODE.... | $1,000 | $0 | Mar 2, 2017 |
| Jan 12, 2017 | 38252074K | RESOLVE | CLASS - 2 | SEC: 28-304.7. 100R07. THE OWNER SHALL HAVE A MAINTENANCE CONTRACT W/ AN APPROVED AGENCY TO PERFORM ELEVATOR REPAIR W... | $0 | $0 | Mar 2, 2017 |
| Jan 12, 2017 | 38252726R | ACTIVE | CLASS - 1 | 401.4 UNLICENSED ACTIVITY.ILLEGALLY ENGAGING IN ANY BUSINESS OR OCCUPATION WITHOUT REQUIRED LICENSE OR OTHER AUTHORIZ... | $12,500 | $0 | Aug 10, 2017 |
| Nov 14, 2016 | 38251088R | RESOLVE | CLASS - 1 | 5J159U15,68B7,70P16 5 DOOR ZONE RESTRICTOR NEEDS ADJUSTMENT 59-PROVIDE BRAKE MAINTENANCE TAG AS PER A17.1 2003 AND AP... | $1,000 | $0 | Dec 29, 2016 |
| Apr 11, 2016 | 38242093R | RESOLVE | CLASS - 2 | 15M07,59U15,68B07 NO CERTIFICATE IN CAR/NO SIGN IN CAR AS TO LOCATIONOF CERTIFICATE, NO TAG STATING DATE OF BRAKE SER... | $250 | $0 | May 26, 2016 |
| Feb 24, 2016 | 38240239L | RESOLVE | CLASS - 1 | 97X10 FAILURE TO MAINTAIN BDG IN CODE COMPLIANT MANNER SERVICE EQUIPM NT ELEVATOR AS PER BC 3001.2 AND 27-987. DOB RE... | $5,000 | $0 | Apr 14, 2016 |
| Feb 8, 2016 | 38240229H | RESOLVE | CLASS - 1 | CLASS07M07,CLASS05J01,17H11,10H11,59U07,11P07,70P07,41W07,99M07,68B07.07M07-PROVIDE DOOR RESTRICTOR MISSING; 07M07-AD... | $1,000 | $0 | Mar 24, 2016 |
| Dec 15, 2015 | 38239648Y | ACTIVE | CLASS - 2 | 02-X-10,35-I-10,39-Y-02,42-D-06,60-X-10,70-O-02:02-X-2WAY COMMUNICATION-INOPERABLE.35-I-REPAIR-TOC-RUNBOX.42--D-SECUR... | $2,500 | $0 | Feb 4, 2016 |
| Sep 10, 2014 | 35066906X | ACTIVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMM ORDER TO FILE A CERT OF CORRECTION WITH THE DOB.ON 09/20/24 DURING PHYSICAL INSP I OB... | $4,000 | $0 | Oct 30, 2014 |
| Jun 4, 2014 | 35066443Z | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERT OF CORRECTION WITH THE DEPT OF BLDGS. VIOLATIONS 34932... | $0 | $0 | Nov 20, 2014 |
| Jun 4, 2014 | 35066444K | ACTIVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS. ADDRESS ABOVE HAVE A LAUNDRY FACILITY INSTALLE... | $6,000 | $0 | Aug 7, 2014 |
| Jul 30, 2013 | 38227851L | RESOLVE | CLASS - 2 | 100B10,40O02,39O02,70O02,44H11,52H11,42G11,68B7. 100- PHONE NOT WORKING, FUSES ARE JUMPED OUT, SHEAVE & HOIST ROPES A... | $2,500 | $0 | Sep 19, 2013 |
| May 28, 2013 | 38227477K | RESOLVE | CLASS - 2 | 50M07,70O02,39O02,05L11,72M07,68M07,40O02,52H11. 50-COVERS ON GEN; 70-CLEAN PIT; 72-INSTALL PIT STOPS WOW LADDER SIDE... | $2,500 | $0 | Jul 18, 2013 |
| Jan 31, 2013 | 34932271N | RESOLVE | CLASS - 1 | GAS BEING SUPPLIED TO BLDG W/O INSPECTIONS AND CERTIFICATION BY DOB FOUND THAT THE GAS SUPPLING THE TEMP BOILER WAS N... | $1,000 | $0 | Jun 6, 2013 |
| Jan 31, 2013 | 34932264P | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. FOUND THAT ADDRESS ABOVE HAS REMOVED ITS OLD BOILERAND WATER HEATERS.ALSO HAS INSTALLED A TEMP BOI... | $0 | $0 | Apr 11, 2013 |
| Jan 31, 2013 | 34932267K | ACTIVE | CLASS - 1 | BC903.2.10.6 FAILURE TO PROVIDE SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED (2 OR MORE GAS DRYERS) FOUND THAT ADDRE... | $1,600 | $0 | May 9, 2013 |
| Jan 31, 2013 | 34932268M | ACTIVE | CLASS - 1 | WORK W/O A PERMIT. FOUND THAT ADDRESS ABOVE INSTALLED TWO GAS DRYERS ON TOP FLOOR OF BUILDING W/O ISSUED/APPROVED PER... | $1,600 | $0 | May 9, 2013 |
| Jan 31, 2013 | 34932270L | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. FOUND THAT NEW YORK HEATING CORP HAS REMOVED THE BUILDINGS OLD BOILER AND WATER HEATER.THEY ALSO H... | $0 | $0 | Jun 6, 2013 |
| Jan 31, 2013 | 34932272P | RESOLVE | CLASS - 1 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. GAS LINE IN BOILER ROOM WAS RE-ROUTED TO FEE TEMP BOILER THAT ... | $0 | $0 | Jun 6, 2013 |
| Jan 31, 2013 | 34932273R | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER RE:INSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER... | $0 | $0 | Jun 6, 2013 |
| Jan 31, 2013 | 34932265R | ACTIVE | CLASS - 1 | GAS BEING SUPPLIED TO BUILDING W/O INSPECTION AND CERTIFICATION BY DOBFOUND THAT TEMP BOILER SET UP ON ROOF HAS GAS B... | $1,000 | $0 | Apr 11, 2013 |