ECB violations

301-305 West 130 Street, Manhattan • Block 01958 • Lot 0001

118 records

Environmental Control Board violations, which carry a hearing and a penalty.

Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 4, 2026 39199027Y ACTIVE CLASS - 2 OBSERVED AT CLASSROOM #3 EXIT DOOR IN-DISREPAIR/NOT CLOSING WHEN TESTED, REPAIR/REPLACE DOOR; REPAIR/REPLACE DOOR $625 $625 Oct 8, 2026
Jul 13, 2026 39195788K ACTIVE CLASS - 1 VF.... R T S... 97-X-17 ..ELEVATOR IN BUILDING OUT OF SERVISE , UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERV... $1,250 $1,250 Sep 17, 2026
Jun 5, 2026 39555096X ACTIVE CLASS - 2 AT TIME OF INSPECTION, I OBSERVED SIDE WALK SHED IN PLACE AT EXPOSURE#3, MISSING CAPS FROM THE BOLTS. THIS CREATES SH... $2,400 $2,400 Mar 18, 2027
Oct 31, 2025 35717924X RESOLVE CLASS - 2 FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 WEST(1) EX... $0 $0 Jan 8, 2026
Sep 24, 2024 39125585R RESOLVE CLASS - 2 FOUND ON LAARS BOILER MODEL # MTZV-750, FOUND LEAKING FLANGE ON FRONT OF BOILER AND CORROSION ON BRASS COUPLING. $0 $0 Dec 5, 2024
Aug 28, 2024 39123359J RESOLVE CLASS - 1 CEASE USE: DOOR ZONE RESTRICTOR NOT WORKING PROPERLY. THIS SAFETY DEVICE PREVENTS THE CAB DOOR FROM OPENING IN BETWEE... $1,250 $0 Apr 21, 2025
Jun 18, 2024 39117212Y RESOLVE CLASS - 2 I OBSERVED ACTIVE WORK IN PROGRESS ON EXTERIOR WALLS, 3-MAN CREW, NO ONE WAS ABLE TO SUPPLY DOB APPROVED DRAWINGS/PLA... $0 $0 Aug 22, 2024
Jun 18, 2024 39117213X RESOLVE CLASS - 2 I INSPECTED THE LOBBY AND OTHER FLOOR LEVELS AND DID NOT OBSERVE THE TENANT PROTECTION PLAN OR NOTICE POSTED ANYWHERE... $312 $0 Aug 22, 2024
Apr 11, 2024 37027537K RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B AND 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTE... $6,250 $1,850 Aug 8, 2024
Jan 4, 2024 39524523J RESOLVE CLASS - 2 AT TIME OF INSPECTION OF 7 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE NOT TO CODE SPECIFICATIONS 1. STO... $2,400 $2,400 Nov 12, 2026
Oct 19, 2022 37022764H RESOLVE CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL ... $3,125 $0 Feb 2, 2023
Aug 5, 2022 39067461M RESOLVE CLASS - 1 ELEVATOR CURRENTLY NO IN SERVCE/OUT OF ORDER. REMEDY: REPAIR ELEVATOR AND RESTORE TO SERVICE $312 $0 Sep 22, 2022
Jul 29, 2022 39504317K RESOLVE CLASS - 2 NOTE: OBSERVED A SIDEWALK SHED AT EXP1, 2 & SOME AREA HAVE INADEQUATE LIGHTING (BC3307.6.4.8) UNDER THE SHED. OBSERVE... $625 $0 Sep 15, 2022
Dec 2, 2021 35635129H RESOLVE CLASS - 3 FAILURE TO POST EXTERIOR WALL CONDITION CERTIFICATE AS REQUIRED UNDER 1RDNY 103-04(F).REMEDY:POST CERTIFICATE ON SITE... $0 $0 Mar 3, 2022
Nov 29, 2021 39051823Y RESOLVE CLASS - 2 RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE BY THIS DEPARTMENT. $310 $0 Mar 17, 2022
Oct 8, 2021 37022067M RESOLVE CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE7B,8B,9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITI... $1,250 -$1,250 Aug 11, 2022
Sep 15, 2021 39047509Y RESOLVE CLASS - 1 FOUND ELEVATOR IS OUT OF SERVICE. RESTORE TO SERVICE. $3,125 $0 Apr 7, 2022
Aug 10, 2021 35585277R RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.NOTE AT THE TIME OF INSPECTION OBSERVED A HD SWS AT EXP1,2,AND... $2,400 $2,400 Mar 31, 2022
Aug 5, 2021 39045569R RESOLVE CLASS - 1 FOUND DOOR RESTRICTOR IS NOT WORKING. CEASE USED. REPAIR AND ADJUST. RE-INSPECTION IS REQUIRED. NO ACCESS TO THE ELEV... $3,125 $0 Sep 23, 2021
Jul 12, 2021 39044286M RESOLVE CLASS - 1 FOUND ELEVATOR OUT OF SERVICE. RESTORE TO SERVICE. $3,125 $0 Aug 26, 2021
Jul 6, 2021 35533524K RESOLVE CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39041281J ISSUED ON 05/17/21 & TO FILE A CERT OF CORREC... $0 $0 Sep 16, 2021
Jun 1, 2021 37021397K RESOLVE CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8B REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTEN... $5,000 $0 Oct 7, 2021
May 25, 2021 39041686H RESOLVE CLASS - 2 FOUND ELEVATOR IS NOT WORKING (OUT OF SEVICE). RESTORE TO SERVICE. $1,562 $0 Jul 15, 2021
May 17, 2021 39041281J RESOLVE CLASS - 1 EXIT DOOR WITH PANIC BAR LEADING TO FREDERICK DOUGLAS BLVD DOES NOT OPEN PROPERLY AND PANIC BAR LATCH IS IS JAMMED., ... $312 $0 Aug 18, 2022
Mar 17, 2021 35552480L RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION L3307.6.4.8-NOTE AT THE TIME OF MY INSPECTION OBSERVED A HD SW... $2,400 $0 Apr 7, 2022
Jan 25, 2021 39035379R RESOLVE CLASS - 2 PHONE NEEDS TO BE ROUTED TO OUTSIDE ELEVATOR COMPANY IF SECURITY IS NOT AT FRONT DESK. FIRE EXTINGUISHER TAG EXPIRED.... $310 $0 Aug 26, 2021
Dec 17, 2020 35509266R RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. NOTE AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHED IN PLACE ... $5,000 $0 Apr 7, 2022
Dec 17, 2020 35509267Z RESOLVE CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHED IN PLACE... $0 $0 Mar 4, 2021
Sep 3, 2020 35473983H RESOLVE CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION AT JOB SITE AT TIME OF INSPECTION. NOTE:ARRIVED AT JOB SITE NOTICED... $0 $0 Nov 12, 2020
Aug 17, 2020 35538639N RESOLVE CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES.EXPOSURE 1,SOUTH ELEVATION:SPALLED BRICKS AT WI... $0 $0 Oct 22, 2020
Aug 6, 2020 35499841H RESOLVE CLASS - 1 SEC. 3307.6.5.3 RESPONSIBILITY FOR MAINTENANCE & USE. AT TIME OF COMP INSPECTION I OBSERVED SIDEWALK SHED ERECTED & I... $2,500 $0 Oct 15, 2020
Jun 25, 2020 39024523Z RESOLVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... $1,250 $0 Jul 8, 2021
May 20, 2020 37018978L RESOLVE CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B & 8B REPORT CRITICALEXAMINATION DOCUMENTING CONDITION OF EXTERIOR W... $0 $0 May 13, 2021
May 19, 2020 39022494J RESOLVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF K.3 2014 NYCBC THIS IS A CONTROLLER FE... $1,250 $0 Oct 27, 2022
May 19, 2020 39022470P RESOLVE CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF K.3 2014 NYCBC THIS IS A CONTROLLER FE... $1,250 $0 Mar 25, 2021
Sep 11, 2019 39009338L RESOLVE CLASS - 3 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS: NOTED: UPON INSPECTION OBSERVED THE ENTRANCE DOOR TO UNIT 1... $0 $0 Jan 30, 2020
Sep 11, 2019 39009337J RESOLVE CLASS - 2 FAILURE TO POST SAFE CONSTRUCTION BILL OF RIGHTS: NOTED: AT TIME OF INSPECTION CONDUCTED WALK-THROUGH OF BUILDING. I ... $0 $0 Jan 30, 2020
May 7, 2019 35418510X RESOLVE CLASS - 2 FAILURE TO MAINTAIN SIDEWALK SHED. AT TIME OF INSPECTION OBSERVED A SIDEWALK SHED IN LACE AT EXP1. DURING INSPECTION ... $2,400 $0 Sep 19, 2019
Dec 27, 2018 38267304Z RESOLVE CLASS - 2 42N11,70O2,39O2. 42N11-CONTROLLER HAVE A PUMP FUES BYPASS REPLACE 70O2-PIT DIRTY CLEAN; 39O2-CAR TOP DIRTY CLEAN. $0 $0 Feb 21, 2019
Oct 15, 2018 37013221R RESOLVE CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... $3,125 $0 Mar 21, 2019
Oct 15, 2018 37012769H RESOLVE CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... $6,280 $0 Mar 7, 2019
Jun 20, 2018 32097089H RESOLVE CLASS - 2 5B,50,50A,50B,50C,50D,50E. 50-TEST HOLE IN BOILER FLUE INCORRECTLY PLUGGED; 50A- BOILER FLUE CLAP IS CORRODED; 50B-H.... $1,562 $0 Aug 9, 2018
Apr 2, 2018 35286046J RESOLVE CLASS - 2 FAILURE TO FILE SITE SAFETY JOB.PARTIAL SWO FACADE WORK.NOTED:AT TIME OF INSPECTION I OBSERVED SWS IN PLACE FOR FACAD... $0 $0 May 17, 2018
Mar 30, 2018 35286093M RESOLVE CLASS - 2 SIDEWALK SHED PARAPET SIGN IS NOT IN COMPLIANCE WITH SECTION.NOTED:@ TIME OF INSPECTION SIDEWALK SHED PARAPET SIGN IS... $0 $0 May 17, 2018
Mar 14, 2018 38261953L RESOLVE CLASS - 2 2X10,42D6,59D6,59E1. 2X10-IN CAR PHONE INOPERATIVE REPAIR; 42D6- PROPERLY SECURE PS RELAY ON CONTROLLER; 59D6-PROPERL... $0 $0 May 3, 2018
Nov 14, 2017 38259581R RESOLVE CLASS - 1 CEASE USE. 5A10. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED & RENDERED INOPERATIVE. THIS IS A SAFETY DEVICE... $1,000 $0 Jan 4, 2018
Oct 11, 2017 38258439L RESOLVE CLASS - 2 70O2,70M7,70I10. (70M)PROVIDE SIGNAGE ON DOOR (PIT DOOR ACCESS). (70I)REPAIR PIT DOOR LOCK. $0 $0 Nov 30, 2017
Aug 2, 2017 38256818M RESOLVE CLASS - 1 45.X.10, 57.BB.07. 45-X-GOVERNOR SWITCH-INOPERATIVE $1,000 $0 Dec 7, 2017
Dec 22, 2016 38251840X RESOLVE CLASS - 1 CU-1X10,5X10,68B7,100E1. 1X10 IN CAR STOP SWITCH INOPERATIVE;5 DOOR ZONE RESTRICTOR INOPERATIVE;100 COMPENSATION CHAI... $0 $0 May 15, 2017
Nov 17, 2016 35199932Z RESOLVE CLASS - 2 TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. NOTED:PERMIT FOR SIDEWALK SHED AT EXP#1 EXPIRED ON 09/05/15 ... $1,000 $0 Jan 5, 2017