ECB violations
301-305 West 130 Street, Manhattan • Block 01958 • Lot 0001
118 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Aug 4, 2026 | 39199027Y | ACTIVE | CLASS - 2 | OBSERVED AT CLASSROOM #3 EXIT DOOR IN-DISREPAIR/NOT CLOSING WHEN TESTED, REPAIR/REPLACE DOOR; REPAIR/REPLACE DOOR | $625 | $625 | Oct 8, 2026 |
| Jul 13, 2026 | 39195788K | ACTIVE | CLASS - 1 | VF.... R T S... 97-X-17 ..ELEVATOR IN BUILDING OUT OF SERVISE , UPON INSPECTION THE DEVICE IS FOUND TO BE OUT OF SERV... | $1,250 | $1,250 | Sep 17, 2026 |
| Jun 5, 2026 | 39555096X | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION, I OBSERVED SIDE WALK SHED IN PLACE AT EXPOSURE#3, MISSING CAPS FROM THE BOLTS. THIS CREATES SH... | $2,400 | $2,400 | Mar 18, 2027 |
| Oct 31, 2025 | 35717924X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 WEST(1) EX... | $0 | $0 | Jan 8, 2026 |
| Sep 24, 2024 | 39125585R | RESOLVE | CLASS - 2 | FOUND ON LAARS BOILER MODEL # MTZV-750, FOUND LEAKING FLANGE ON FRONT OF BOILER AND CORROSION ON BRASS COUPLING. | $0 | $0 | Dec 5, 2024 |
| Aug 28, 2024 | 39123359J | RESOLVE | CLASS - 1 | CEASE USE: DOOR ZONE RESTRICTOR NOT WORKING PROPERLY. THIS SAFETY DEVICE PREVENTS THE CAB DOOR FROM OPENING IN BETWEE... | $1,250 | $0 | Apr 21, 2025 |
| Jun 18, 2024 | 39117212Y | RESOLVE | CLASS - 2 | I OBSERVED ACTIVE WORK IN PROGRESS ON EXTERIOR WALLS, 3-MAN CREW, NO ONE WAS ABLE TO SUPPLY DOB APPROVED DRAWINGS/PLA... | $0 | $0 | Aug 22, 2024 |
| Jun 18, 2024 | 39117213X | RESOLVE | CLASS - 2 | I INSPECTED THE LOBBY AND OTHER FLOOR LEVELS AND DID NOT OBSERVE THE TENANT PROTECTION PLAN OR NOTICE POSTED ANYWHERE... | $312 | $0 | Aug 22, 2024 |
| Apr 11, 2024 | 37027537K | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B AND 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTE... | $6,250 | $1,850 | Aug 8, 2024 |
| Jan 4, 2024 | 39524523J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OF 7 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE NOT TO CODE SPECIFICATIONS 1. STO... | $2,400 | $2,400 | Nov 12, 2026 |
| Oct 19, 2022 | 37022764H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL ... | $3,125 | $0 | Feb 2, 2023 |
| Aug 5, 2022 | 39067461M | RESOLVE | CLASS - 1 | ELEVATOR CURRENTLY NO IN SERVCE/OUT OF ORDER. REMEDY: REPAIR ELEVATOR AND RESTORE TO SERVICE | $312 | $0 | Sep 22, 2022 |
| Jul 29, 2022 | 39504317K | RESOLVE | CLASS - 2 | NOTE: OBSERVED A SIDEWALK SHED AT EXP1, 2 & SOME AREA HAVE INADEQUATE LIGHTING (BC3307.6.4.8) UNDER THE SHED. OBSERVE... | $625 | $0 | Sep 15, 2022 |
| Dec 2, 2021 | 35635129H | RESOLVE | CLASS - 3 | FAILURE TO POST EXTERIOR WALL CONDITION CERTIFICATE AS REQUIRED UNDER 1RDNY 103-04(F).REMEDY:POST CERTIFICATE ON SITE... | $0 | $0 | Mar 3, 2022 |
| Nov 29, 2021 | 39051823Y | RESOLVE | CLASS - 2 | RESTORE TO SERVICE SO A FULL INSPECTION CAN BE MADE BY THIS DEPARTMENT. | $310 | $0 | Mar 17, 2022 |
| Oct 8, 2021 | 37022067M | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE7B,8B,9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITI... | $1,250 | -$1,250 | Aug 11, 2022 |
| Sep 15, 2021 | 39047509Y | RESOLVE | CLASS - 1 | FOUND ELEVATOR IS OUT OF SERVICE. RESTORE TO SERVICE. | $3,125 | $0 | Apr 7, 2022 |
| Aug 10, 2021 | 35585277R | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.NOTE AT THE TIME OF INSPECTION OBSERVED A HD SWS AT EXP1,2,AND... | $2,400 | $2,400 | Mar 31, 2022 |
| Aug 5, 2021 | 39045569R | RESOLVE | CLASS - 1 | FOUND DOOR RESTRICTOR IS NOT WORKING. CEASE USED. REPAIR AND ADJUST. RE-INSPECTION IS REQUIRED. NO ACCESS TO THE ELEV... | $3,125 | $0 | Sep 23, 2021 |
| Jul 12, 2021 | 39044286M | RESOLVE | CLASS - 1 | FOUND ELEVATOR OUT OF SERVICE. RESTORE TO SERVICE. | $3,125 | $0 | Aug 26, 2021 |
| Jul 6, 2021 | 35533524K | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39041281J ISSUED ON 05/17/21 & TO FILE A CERT OF CORREC... | $0 | $0 | Sep 16, 2021 |
| Jun 1, 2021 | 37021397K | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8B REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTEN... | $5,000 | $0 | Oct 7, 2021 |
| May 25, 2021 | 39041686H | RESOLVE | CLASS - 2 | FOUND ELEVATOR IS NOT WORKING (OUT OF SEVICE). RESTORE TO SERVICE. | $1,562 | $0 | Jul 15, 2021 |
| May 17, 2021 | 39041281J | RESOLVE | CLASS - 1 | EXIT DOOR WITH PANIC BAR LEADING TO FREDERICK DOUGLAS BLVD DOES NOT OPEN PROPERLY AND PANIC BAR LATCH IS IS JAMMED., ... | $312 | $0 | Aug 18, 2022 |
| Mar 17, 2021 | 35552480L | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION L3307.6.4.8-NOTE AT THE TIME OF MY INSPECTION OBSERVED A HD SW... | $2,400 | $0 | Apr 7, 2022 |
| Jan 25, 2021 | 39035379R | RESOLVE | CLASS - 2 | PHONE NEEDS TO BE ROUTED TO OUTSIDE ELEVATOR COMPANY IF SECURITY IS NOT AT FRONT DESK. FIRE EXTINGUISHER TAG EXPIRED.... | $310 | $0 | Aug 26, 2021 |
| Dec 17, 2020 | 35509266R | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION. NOTE AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHED IN PLACE ... | $5,000 | $0 | Apr 7, 2022 |
| Dec 17, 2020 | 35509267Z | RESOLVE | CLASS - 2 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTE AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHED IN PLACE... | $0 | $0 | Mar 4, 2021 |
| Sep 3, 2020 | 35473983H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION AT JOB SITE AT TIME OF INSPECTION. NOTE:ARRIVED AT JOB SITE NOTICED... | $0 | $0 | Nov 12, 2020 |
| Aug 17, 2020 | 35538639N | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES.EXPOSURE 1,SOUTH ELEVATION:SPALLED BRICKS AT WI... | $0 | $0 | Oct 22, 2020 |
| Aug 6, 2020 | 35499841H | RESOLVE | CLASS - 1 | SEC. 3307.6.5.3 RESPONSIBILITY FOR MAINTENANCE & USE. AT TIME OF COMP INSPECTION I OBSERVED SIDEWALK SHED ERECTED & I... | $2,500 | $0 | Oct 15, 2020 |
| Jun 25, 2020 | 39024523Z | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Jul 8, 2021 |
| May 20, 2020 | 37018978L | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B & 8B REPORT CRITICALEXAMINATION DOCUMENTING CONDITION OF EXTERIOR W... | $0 | $0 | May 13, 2021 |
| May 19, 2020 | 39022494J | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF K.3 2014 NYCBC THIS IS A CONTROLLER FE... | $1,250 | $0 | Oct 27, 2022 |
| May 19, 2020 | 39022470P | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF K.3 2014 NYCBC THIS IS A CONTROLLER FE... | $1,250 | $0 | Mar 25, 2021 |
| Sep 11, 2019 | 39009338L | RESOLVE | CLASS - 3 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS: NOTED: UPON INSPECTION OBSERVED THE ENTRANCE DOOR TO UNIT 1... | $0 | $0 | Jan 30, 2020 |
| Sep 11, 2019 | 39009337J | RESOLVE | CLASS - 2 | FAILURE TO POST SAFE CONSTRUCTION BILL OF RIGHTS: NOTED: AT TIME OF INSPECTION CONDUCTED WALK-THROUGH OF BUILDING. I ... | $0 | $0 | Jan 30, 2020 |
| May 7, 2019 | 35418510X | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN SIDEWALK SHED. AT TIME OF INSPECTION OBSERVED A SIDEWALK SHED IN LACE AT EXP1. DURING INSPECTION ... | $2,400 | $0 | Sep 19, 2019 |
| Dec 27, 2018 | 38267304Z | RESOLVE | CLASS - 2 | 42N11,70O2,39O2. 42N11-CONTROLLER HAVE A PUMP FUES BYPASS REPLACE 70O2-PIT DIRTY CLEAN; 39O2-CAR TOP DIRTY CLEAN. | $0 | $0 | Feb 21, 2019 |
| Oct 15, 2018 | 37013221R | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $3,125 | $0 | Mar 21, 2019 |
| Oct 15, 2018 | 37012769H | RESOLVE | CLASS - 2 | FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPUR... | $6,280 | $0 | Mar 7, 2019 |
| Jun 20, 2018 | 32097089H | RESOLVE | CLASS - 2 | 5B,50,50A,50B,50C,50D,50E. 50-TEST HOLE IN BOILER FLUE INCORRECTLY PLUGGED; 50A- BOILER FLUE CLAP IS CORRODED; 50B-H.... | $1,562 | $0 | Aug 9, 2018 |
| Apr 2, 2018 | 35286046J | RESOLVE | CLASS - 2 | FAILURE TO FILE SITE SAFETY JOB.PARTIAL SWO FACADE WORK.NOTED:AT TIME OF INSPECTION I OBSERVED SWS IN PLACE FOR FACAD... | $0 | $0 | May 17, 2018 |
| Mar 30, 2018 | 35286093M | RESOLVE | CLASS - 2 | SIDEWALK SHED PARAPET SIGN IS NOT IN COMPLIANCE WITH SECTION.NOTED:@ TIME OF INSPECTION SIDEWALK SHED PARAPET SIGN IS... | $0 | $0 | May 17, 2018 |
| Mar 14, 2018 | 38261953L | RESOLVE | CLASS - 2 | 2X10,42D6,59D6,59E1. 2X10-IN CAR PHONE INOPERATIVE REPAIR; 42D6- PROPERLY SECURE PS RELAY ON CONTROLLER; 59D6-PROPERL... | $0 | $0 | May 3, 2018 |
| Nov 14, 2017 | 38259581R | RESOLVE | CLASS - 1 | CEASE USE. 5A10. DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED & RENDERED INOPERATIVE. THIS IS A SAFETY DEVICE... | $1,000 | $0 | Jan 4, 2018 |
| Oct 11, 2017 | 38258439L | RESOLVE | CLASS - 2 | 70O2,70M7,70I10. (70M)PROVIDE SIGNAGE ON DOOR (PIT DOOR ACCESS). (70I)REPAIR PIT DOOR LOCK. | $0 | $0 | Nov 30, 2017 |
| Aug 2, 2017 | 38256818M | RESOLVE | CLASS - 1 | 45.X.10, 57.BB.07. 45-X-GOVERNOR SWITCH-INOPERATIVE | $1,000 | $0 | Dec 7, 2017 |
| Dec 22, 2016 | 38251840X | RESOLVE | CLASS - 1 | CU-1X10,5X10,68B7,100E1. 1X10 IN CAR STOP SWITCH INOPERATIVE;5 DOOR ZONE RESTRICTOR INOPERATIVE;100 COMPENSATION CHAI... | $0 | $0 | May 15, 2017 |
| Nov 17, 2016 | 35199932Z | RESOLVE | CLASS - 2 | TEMPORARY CONSTRUCTION EQUIPMENT ON SITE-EXPIRED PERMIT. NOTED:PERMIT FOR SIDEWALK SHED AT EXP#1 EXPIRED ON 09/05/15 ... | $1,000 | $0 | Jan 5, 2017 |