421 Dr M L King Jr Boulevard, Manhattan
Manhattan • Block 01966 • Lot 0059 • Zip: 10027
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Times Square 27 min 7 walking, 20 riding
- Penn Station 29 min 7 walking, 22 riding
- Grand Central 35 min 7 walking, 28 riding
- Union Square 40 min 7 walking, 33 riding
- Fulton Street 41 min 7 walking, 34 riding
- Downtown Brooklyn 46 min 7 walking, 39 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Ferry
Bus
Citi Bike
Places nearby
Sugar Monk
No description yet
La Salle Dumpling Room
No description yet
Jin Ramen
No description yet
Yemeni Restaurant
No description yet
The View
No description yet
Vinatería
No description yet
Cafe Massawa
No description yet
314 Pizza Pasta & Cocktail Bar
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation Jul 27, 2026
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN GLAZED FINISH AT BATHTUB I...
-
HPD violation Jul 27, 2026
Class B
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN TH...
-
HPD violation Jul 27, 2026
Class B
§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING ...
-
HPD violation Jul 27, 2026
Class B
§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHRO...
-
HPD violation Jul 27, 2026
Class B
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN TH...
-
HPD violation Jul 27, 2026
Class B
§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON ...
2025
-
DOB violation Nov 14, 2025
LBLVIO-LOW PRESSURE BOILER BOILER REQUIRED
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
2024
2023
-
CLASS - 2
AT THE TIME OF INSPECTION IN APARTMENT #5 I OBSERVED SEVERAL UNGROUNDED OUTLETS THROUGHOUT THE ENTIRE APARTMENT, COMP...
-
CLASS - 1
AT THE TIME OF INSPECTION I OBSERVED IN APARTMENT #9,15,17 AND THE ENTIRE HALLWAY ALL FLOORS. NEW ELECTRICAL BUILD OU...
2021
-
Alteration Type II
COMBINING SECOND FLOOR APARTMENT UNITS #1 & 2 INTO A ONE 4-BEDROOM AND 2 BATH APARTEMTN UNIT COMPLIANCE WITH TPP ...
-
DOB violation Apr 29, 2021
EGRADE-FAILURE TO POST ENERGY GRADE/SCORE NONE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
2020
-
DOB violation Aug 2, 2020
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
-
DOB violation May 2, 2020
BENCH-FAILURE TO BENCHMARK NONE
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
2019
-
CLASS - 2
FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35432180N ISSUED ON 9/28/19 AND TO FILE ...
-
CLASS - 2
FAILURE TO NOTIFY THE DEPARTMENT 72 HOURS PRIOR TO THE COMMENCEMENT OF WORK, ASKED THE GC FOR THE REFERENCE NUMBER FO...
-
CLASS - 1
TAMPERED WITH .REMOVWED OR DEFACED A WRITTEN POSTED STOP WORK ORDER NOTED UPON INSPECTION OBSERVED THE FULL STOP WORK...
-
CLASS - 2
WORK WITHOUT A PERMIT NOTED UPON INSPECTION OBSERVED NEW ELECTRICAL WORK IN HALLWAYS 1ST FLOOR THORUGH 5TH FLOOR EACH...
-
Alteration Type III
NEW WALLS AND CEILING GYPSUM BOARD FINISHES IN COMMON HALLWAYS OF APARTMENT UNITS OCCUPIED FLOORS TWO TO FIFTH, FIRST...
2017
-
Alteration Type II
HEREWITH FILE TO RENOVATE EXISTING APARTMENT UNIT #15 INCLUDES G.W.B. WALL, PAINT, NEW DOORS AND GENERAL CONSTRUCTION...
-
Alteration Type II
HEREWITH FILE TO RENOVATE EXISTING APARTMENT UNIT #7 INCLUDES G.W.B. WALL, PAINT, NEW DOORS AND GENERAL CONSTRUCTION....
2015
-
Alteration Type II
APPLICATION FOR PROPOSED INTERIOR WORK AT THE EXISTING FIRST FLOOR COMMERCIAL RETAIL STORE (USE GROUP 6). REPLACE STO...
2014
-
Alteration Type II
HEREWITH FILE TO RENOVATE EXISTING APARTMENT UNIT #2 INCLUDES REPLACE PLUMBING FIXTURES, G.W.B. WALL, PAINT, K. CABIN...
2012
-
DOB violation Jun 13, 2012
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
1993
-
DOB violation Mar 18, 1993
LL6291-LOCAL LAW 62/91 - BOILERS BOILER REQUIRED
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records