ECB violations
102-104 Convent Avenue, Manhattan • Block 01970 • Lot 0055
30 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 9, 2023 | 39077273Y | RESOLVE | CLASS - 2 | REPAIR PHONE LINE... UNABLE TO REACH ELEVATOR COMPANY. EMERGENCY PHONE MUST BE MONITOIRED 24/7, ADJUST CLUTCH TO PREV... | $310 | $0 | Mar 16, 2023 |
| Apr 20, 2020 | 35490132Y | RESOLVE | CLASS - 1 | SEC. 3307.2.4 REQUIRED MEANS OF EGRESS. NOTE: AT TIME OF INSPECTION ONAN ACTIVE JOBSITE OF A 6 STY BLDG,OBSERVED THAT... | $0 | $0 | Mar 11, 2021 |
| Apr 20, 2020 | 35490133X | RESOLVE | CLASS - 1 | SEC. 3314.1 SUPPORTED SCAFFOLD(MODIFIED). NOTE: AT TIME OF INSPECTION ON ACTIVE JOBSITE OF A 6 STY BLDG OBSERVED @ EX... | $2,500 | $0 | Oct 22, 2020 |
| Apr 20, 2020 | 35490135J | RESOLVE | CLASS - 1 | OPERATION OF HOISTING EQUIPMENT UNSAFE. NOTE: AT TIME OF INSPECTION OFAN ALT JOB IN PROGRESS,I OBSERVED A BETA MAX IN... | $10,000 | $0 | Jan 21, 2021 |
| Apr 20, 2020 | 35490136L | RESOLVE | CLASS - 1 | DOCUMENTS NEED TO BE KEPT ON SITE. NOTE: AT TIME OF INSPECTION OF AN ALT JOB IN PROGRESS,I OBSERVE CHIMNEY TUBE NOT(E... | $6,250 | $0 | Aug 24, 2020 |
| Apr 20, 2020 | 35490137N | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE &/OR HAVE CONSTRUCTION SUPERINTENDENT PRESENT AT SITE AS REQUIRE. NOTE: AT THE TIME OF INSPECTIO... | $625 | $0 | Jan 21, 2021 |
| Apr 20, 2020 | 35490138P | RESOLVE | CLASS - 1 | FAILURE TO DESIGNATE &/OR HAVE CONSTRUCTION SUPERINTENDENT PRESENT AT SITE AS REQUIRE. NOTE: AT THE TIME OF INSPECTIO... | $2,500 | $0 | Oct 22, 2020 |
| Apr 20, 2020 | 35490139R | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVE CONSTRUCTION DOCUMENTS & OR APPROVED AMENDMENTS(COLD FORM STEEL). NOTE: AT THE TIME ... | $6,250 | $0 | Aug 24, 2020 |
| Apr 20, 2020 | 35490140Y | RESOLVE | CLASS - 2 | SEC. 3307.658 NO PERIODIC INSPECTION PROVIDED. NOTE: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE,NO 6 MON... | $0 | $0 | Jun 25, 2020 |
| Apr 20, 2020 | 35490142H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE PARAPET JOB SIGN PANEL. NOTE: AT TIME OF INSPECTIONI OBSERVED SIDEWALK SHED IN PLACE W/O PROJECT I... | $0 | $0 | Jun 25, 2020 |
| Apr 20, 2020 | 35490134H | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED PLANS & AMENDMENTS. NOTE: AT TIME OFINSPECTION ON AN ACTIVE JOB SITE OF A 6 STY BLD... | $625 | $0 | Aug 24, 2020 |
| Apr 20, 2020 | 35417534X | RESOLVE | CLASS - 1 | 28-104.8.4 INADEQUATE TPP IN PLACE.NOTED:CONTRACTOR IS CURRENTLY WORKING ON JOB#122918101 TO ELARGE PREMISE BY ADDING... | $625 | $0 | Oct 1, 2020 |
| Apr 20, 2020 | 35417533Y | RESOLVE | CLASS - 2 | BC 3303.10 TENANT PROTECTION PLAN NOT BEING COMPARED WITH NOTED:CONTRACTOR CURRENTLY WORKING ON ALT,APP#122918101,WHI... | $0 | $0 | Jun 25, 2020 |
| Apr 20, 2020 | 35490141X | RESOLVE | CLASS - 2 | SEC. 3307.6.5.10 NO LOG BOOK. NOTE: AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHED IN PLACE FAILURE TO PROVIDE DAILY ... | $0 | $0 | Jun 25, 2020 |
| Apr 20, 2020 | 35432522Y | RESOLVE | CLASS - 2 | FAILURE TO POST OR PROPERLY POST PERMIT FOR WORK AT PREMISES.AT THE TIME OF INSPECTION AN CONT. FAILED TO PSOT/DISPLA... | $0 | $0 | Jun 25, 2020 |
| Apr 20, 2020 | 35417532M | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UN-OBSTRUCTED EXIT/EGRESS NOTED:AT EXPOSURES 1 & 3 FIRE ESCAPES ACCESS TO THE FIRE ESCAPE WAS BLOC... | $1,250 | $0 | Oct 1, 2020 |
| Apr 20, 2020 | 35432523X | RESOLVE | CLASS - 2 | FAILURE TO DISTRIBUTE OR POST A NOTICE OF THE SAFE CONSTRUCTION BILL OF RIGHTS IN ACCORDANCE WITH THE HOUSING AND MAI... | $1,250 | $0 | Aug 24, 2020 |
| Apr 20, 2020 | 35490130K | RESOLVE | CLASS - 1 | WORKERS COMP OR DISABILITY INSURANCE. NOTE: AT TIME OF INSPECTION OF AN ACTIVE JOBSITE OF A 6 STY BLDG UNDER JOB#1229... | $5,000 | $0 | Oct 22, 2020 |
| Apr 20, 2020 | 35490131M | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. NOTE: AT TIME OF INSPECTION OF A 6 STY ALT WORK I... | $2,500 | $0 | Oct 22, 2020 |
| Aug 1, 2019 | 39006895K | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION, OBSERVED MULTIPLE VERTICAL CRACKS A... | $0 | -$310 | Sep 19, 2019 |
| Jun 28, 2018 | 35332289Z | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMP CONSTRUCTION-NO GUARDRAILS.AT TIME OF INSECTIO IT WAS... | $2,500 | $0 | Aug 16, 2018 |
| Jun 28, 2018 | 35332290X | RESOLVE | CLASS - 1 | WORK DOES NOT CONFORM TO APPROVED CONSTRUXCTION DOCS AND/OR APPROVED AMENDMENTS.AT TIME OF INSPECTION IT WAS OBSERVED... | $2,500 | $0 | Aug 16, 2018 |
| Apr 3, 2018 | 35314328N | RESOLVE | CLASS - 1 | FAILURE TO MONITOR ADJOINING STRUCTURES FOR MOVEMENT IN ALL DIRECTIONSDURING EXCAVATION-RELATED ACTIVITIES THAT MAY A... | $625 | $0 | Oct 25, 2018 |
| Apr 3, 2018 | 35314329P | RESOLVE | CLASS - 1 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER CODE AT THE TIME OF INSPECTION, THE CONSTRUCTION SUPERINT... | $2,500 | $2,500 | Oct 25, 2018 |
| Oct 16, 2017 | 35287761N | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES AS PER RULE. AT THE TIME OF INSPECTION, THE CONSTRUCTION SUPERIN... | $2,500 | $0 | Jul 26, 2018 |
| Oct 16, 2017 | 35287760L | RESOLVE | CLASS - 1 | 3301.2 FAILURE TO PROVIDE 3 FOOT 6 INCH GUARDRAILS OR EQUIVALENT AROUND ALL FLOOR AND PERIMETER OPENINGS. AT THE TIME... | $8,000 | $0 | Dec 7, 2017 |
| Oct 16, 2017 | 35287762P | RESOLVE | CLASS - 2 | CONSTRUCTION SUPERINTENDENT FAILS TO MAINTAIN AND/OR MAKE JOB SITE LOGS AVAILABLE. AT THE TIME OF INSPECTION, THE REG... | $800 | $0 | Aug 9, 2018 |
| Sep 19, 2009 | 32066985Y | RESOLVE | CLASS - 3 | B354 21A.50A.50B.50C.50D.50E.50F 50A FUEL OIL LEAK AT BURNER 50B TEMPERATURE GAUGE ROTTED 50C OPEN CONTAINERS OF FUEL... | $500 | $0 | Nov 12, 2009 |
| Apr 12, 2006 | 34512162N | RESOLVE | Non-Hazardous | WORK W/O PERMIT. WORK NOTED ERECTED PARTITIONS CREATING TWO (2) BEDROOMS (1) ONE BATHROOM-LIVING/KITCHEN CREATING CLA... | $0 | $0 | Jul 6, 2006 |
| Apr 28, 2000 | 34244296K | RESOLVE | Non-Hazardous | EXIT PASSAGEWAY & CORRIDOR:REQUIRED WIDTH DECREASED BY OBSTRUCTION.NOTED:2FT.DECREASE IN 3RD.FL.CORRIDOR DUE TO STORA... | $2,500 | $0 | Jun 15, 2000 |