ECB violations
151-161 Claremont Avenue, Manhattan • Block 01994 • Lot 0057
24 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Apr 4, 2026 | 35726915Z | ACTIVE | CLASS - 2 | 28-305.1. OWNERS RESPONSIBILITIES-FAILURE TO MAINTAIN RETAINING WALL. AS NOTED:-AT THE TIME OF INSPECTION, OBSERVED A... | $1,250 | $0 | Jun 11, 2026 |
| Feb 25, 2025 | 37033409R | RESOLVE | CLASS - 2 | 1RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103... | $0 | $0 | Jan 21, 2027 |
| Mar 30, 2023 | 35666696X | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT PERMIT NOTE:AT TIME OF INSPECTION,OBSERVED WORK BEING PERFORMED UNDER THE AFOREMENTIONED JOB ... | $1,600 | $0 | Jun 8, 2023 |
| Mar 30, 2023 | 35666692Z | RESOLVE | CLASS - 1 | 28-201.1 INADEQUATE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION,OBSERVED WORK BEING PERFORMED UNDER THE AFOREME... | $625 | $0 | Nov 9, 2023 |
| Mar 30, 2023 | 35666693K | RESOLVE | CLASS - 1 | BC 3303.10 FAILURE TO COMPLY WITH TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION,OBSERVED WORK BEING PERFORMED UND... | $625 | $0 | Nov 9, 2023 |
| Mar 30, 2023 | 35666694M | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE APPROVED/ACCPETED CONSTRUCTION DOCUMENTS AT JOBSITEAT TIME OF INSPECTION.NOTE:AT TIME OF INSPECTIO... | $312 | $0 | Nov 9, 2023 |
| Mar 30, 2023 | 35666695Y | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE SITE SAFETY TRAINING CARD AND OSHA.NOTE:AT TIME OF INSPECTION OBSERVED WORK BEING PERFORMED UNDER ... | $1,250 | $0 | Nov 9, 2023 |
| Nov 19, 2020 | 35541709R | RESOLVE | CLASS - 1 | 28-201.1 INADEQUATE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED THE SUBMITTED TPP UNDER THE AFOREMENTI... | $0 | $0 | Jun 10, 2021 |
| Oct 24, 2019 | 39011764R | RESOLVE | CLASS - 1 | WORK WITHOUT PERMIT. NOTE: DURING TIME OF INSPECTION, OBSERVED MASONRY WORK BEING PERFORMED ON PARAPET WALL WITH NO V... | $0 | $0 | Aug 20, 2020 |
| Nov 28, 2017 | 38259825Y | RESOLVE | CLASS - 2 | 57BB11,59U15,52M07,80B07,68B07,39X10,70X10,40O02-57)EXPIRE FIRE EXTINGUISHER. 59)BRAKE MAINT TAG INSUFFICIENT SPECIFY... | $500 | $0 | Jan 18, 2018 |
| Jul 6, 2016 | 35199129J | RESOLVE | CLASS - 1 | UNQUALIFIED WORKER PERFORMING WORK ON SCAFFOLD PURSUANT 1RCNY 104-20(K). NOTED:@TIME OF INSPECTION FOLLOWING WORKER J... | $2,400 | $0 | Aug 25, 2016 |
| Jul 6, 2016 | 35199128H | RESOLVE | CLASS - 1 | NO RECORD OF DAILY INSPECTION SUSPENDED SCAFFOLD PERFORMED BY AUTHORIZED PERSON @SITE.NOTED:@TIME OF INSPECTION NO DA... | $2,400 | $0 | Aug 25, 2016 |
| Jul 6, 2016 | 35199127X | RESOLVE | CLASS - 1 | 3314.6.3 PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT 28-207.2 &POSTED ON PREMISES.FAILED TO PROVIDE DIFFERENT ... | $1,600 | $0 | Aug 25, 2016 |
| Jul 6, 2016 | 35199126Y | RESOLVE | CLASS - 2 | 3314.4.5.3 EXPIRED TRAINING CARD.NOTED:@TIME OF INSPECTION FOREMAN-FERNANDO LUA SUPERVISING JOBSITE W.EXPIRED TRAININ... | $0 | $0 | Aug 25, 2016 |
| Jan 27, 2010 | 36012446R | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ARCHITECT/ENGINEER REPORT CERTIFYING EXIT/DIRECTIONAL SIGNS ARE CONNECTED TO EMERGENCY POWER SOURC... | $400 | $0 | Mar 31, 2011 |
| May 2, 2008 | 32055844R | RESOLVE | Non-Hazardous | B4A 50.50A.50B 50 MIXING VALVE DEFECTIVE 50A THREADED END ON BOILER SAFETY VALVES DISCHARGE PIPES 50B SWING CHECK VAL... | $0 | $0 | Jun 26, 2008 |
| May 2, 2008 | 32055842N | RESOLVE | Non-Hazardous | B4A 50.50A.50B.50C.50D.50E. 50 BOTH PRESSURE CONTROLS PIPED TO BOILER ON ONE 1/4 PIPE 50A STORAGE IN BOILER RM LOWER ... | $0 | $0 | Jun 26, 2008 |
| May 2, 2008 | 32055843P | RESOLVE | Non-Hazardous | B4A 50 50 BOILER SAFETY VALVE RATLING TAG PAINTED OVER | $0 | $0 | Jun 26, 2008 |
| May 2, 2008 | 32055845Z | RESOLVE | Non-Hazardous | B4A 50.50A.50 BOILER SAFETY VALVES HAVE THREADED ENDS ON DISCHARGE PIPES 50A SWING CHECK VAVLVE MISSING IN BOILER FEE... | $0 | $0 | Jun 26, 2008 |
| Apr 30, 2008 | 34684410Y | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $700 | $0 | Oct 23, 2008 |
| May 5, 2000 | 38093248X | RESOLVE | Non-Hazardous | 75U05. 75U- PERFORM FIVE TEAR TEST. | $0 | $0 | Jun 22, 2000 |
| May 5, 2000 | 38093249H | RESOLVE | Non-Hazardous | 75U05. 75U- FILE AND PERFORM 5 YEAR TEST. | $0 | $0 | Jun 22, 2000 |
| Jan 28, 2000 | 34146956H | RESOLVE | Hazardous | FAILURE TO COMPLY WITH CERTIFICATE OF ON-SITE INSPECTION.STOP WORK ODER#4616 | $0 | $0 | May 25, 2000 |
| Oct 26, 1999 | 34146976P | RESOLVE | Hazardous | OPERATION OF CRANE IN AN UNSAFE MANNER (A) CRANE OPERATING IN AN UN- LEVEL CONDITION (B) DAMAGED SAFETY LATCH ON HOOK... | $5,500 | $0 | Mar 2, 2000 |