ECB violations
41-49 Tiemann Place, Manhattan • Block 01995 • Lot 0016
38 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Mar 18, 2026 | 39180874P | RESOLVE | CLASS - 1 | 2/X/10 OUT SIDE COMM INOPERATIVE REPAIR, 5/L/10 CAR CEASE USE CLASS 1 CAR DOOR RESTRICTOR DEFECTIVE REPAIR, CLASS 1, ... | $1,250 | $1,250 | May 28, 2026 |
| Jan 12, 2026 | 39173357L | ACTIVE | CLASS - 1 | 100/R/17 MISCELLANEOUS ILLEGAL REINSPECTION REQUIRED,WORKING WITH OUT A PERMIT. | $2,500 | $2,500 | Oct 22, 2026 |
| Jul 20, 2021 | 39044700Z | RESOLVE | CLASS - 1 | FOUND OUTSIDE COMMUNICATION (PHONE) IN CAR IS NOT WORKING. REPAIR. DOOR LOCK MONITORING (DLM) IS NOT WORKING. REPAIR ... | $1,250 | $0 | Sep 9, 2021 |
| Jan 17, 2020 | 38272904Z | RESOLVE | CLASS - 1 | 2X10,42M7,40R7,40O2,59BB5,69M7:2-X-10=INOPERATIVE ALARM BELL REPAIR AND PROVIDE IN CONJUNCTION W/ STOP SWITCH/42-M-7=... | $3,125 | $0 | Oct 15, 2020 |
| Nov 25, 2019 | 38265442H | RESOLVE | CLASS - 1 | 97X17,40S7,59BB5:97-X-17=ENTIRE DEVICE REMAINS INOPERATIVE ON A 6 STORY BUILDING CREATING A HAZARDOUS CONDITION AND H... | $3,125 | $0 | Jan 30, 2020 |
| Oct 3, 2019 | 38271882M | RESOLVE | CLASS - 1 | 97-X-17 OUT OF SERVICE, UPON MY INSPECTION THE DEVICE IS FOUND TO BE OUT-OF-SERVICE CREATING A HAZARDOUS CONDITION AS... | $1,250 | $0 | Mar 19, 2020 |
| Feb 9, 2019 | 38268251Z | RESOLVE | CLASS - 2 | 37M07, 40M07,67X10. 37M7-NO ACCESS TO THE OVERHEAD MISSING KEYS. 40M7- NO ACCESS TO THE MACHINE ROOM MISSING KEYS; 67... | $312 | $0 | Jun 6, 2019 |
| Jan 29, 2019 | 38267545J | RESOLVE | CLASS - 1 | 1L10, 2X10,5A10,12L10. 2X10-OUTSIDE COMM INOPERTIVE REPAIR; 6A10-CAR DOOR RESTRICTOR ALTERED REPAIR (CAR DOOR RESTRIC... | $1,250 | $0 | May 30, 2019 |
| Dec 7, 2018 | 38266647X | RESOLVE | CLASS - 1 | 02X10,CU5A10K,39M7,59BB7. 2X10-OUTSIDE COMM INOPERATIVE REPAIR; 5A10-CEASE USE ITEM DOOR ZONE RESTRICTOR HAS BEEN TAM... | $1,250 | $0 | Jan 31, 2019 |
| Oct 27, 2018 | 35355353X | RESOLVE | CLASS - 1 | WORK AFTER W/O VARIDENCE PERMIT CONTRARY TO 28-105.12.5.NOTED;ALTERATION #123347137 FOR REAR APARTMENT AT CELLAR HAVI... | $0 | $0 | Feb 14, 2019 |
| Oct 27, 2018 | 35355352Y | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.A REAR OF PREMISES EXP 3 FIRE ESCAPE (LANDINGS)BLOCKED WITH GARBAGE A... | $1,250 | $0 | Feb 20, 2019 |
| Jun 19, 2018 | 38263520P | RESOLVE | CLASS - 2 | 16D6,5J1,37O2,39O2,71X10,72I10. (16D)ADJUST KEPPER ON BASEMENT,LOBBY & 6TH FLR. (5J)REDUCE GAP ON 2 SPEED CAR DOOR. (... | $625 | $0 | Oct 4, 2018 |
| Mar 12, 2018 | 38261724H | RESOLVE | CLASS - 1 | CEASE USE. 5A10,52D12. (5A)DOOR ZONE RESTRICTOR HAS BEEN TAMPERED & DISABLED & RENDERED INOPERATIVE. THIS IS A SAFETY... | $1,250 | $0 | Jul 5, 2018 |
| Aug 30, 2016 | 35187620L | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN NOV#35164499R ISSUED ON 08/18/15 AND TO FILE A CERTIFICATE OF C... | $6,000 | $0 | Oct 20, 2016 |
| Jul 6, 2016 | 35186681K | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN NOV#35164499R ISSUED ON 08/18/16 AND TO FILE A CERTIFICA... | $0 | $0 | Mar 9, 2017 |
| May 11, 2016 | 38242291H | RESOLVE | CLASS - 2 | 37P16,44E01,40O02,70O02. 40-REMOVE BUILDING MATERIALS. | $500 | $0 | Jun 30, 2016 |
| May 11, 2016 | 35185605Y | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMM'S ORDER CONTAINED IN NOV#35164498P ISSUED ON 8/18/15 & TO FILE A CERT OF CORRECTION PUR... | $2,000 | $0 | Jun 30, 2016 |
| May 11, 2016 | 35185604M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/ THE COMM'S ORDER CONTAINED IN NOV#35164499R ISSUED ON 8/18/15 & TO FILE A CERT OF CORRECTION PUR... | $6,000 | $0 | Jun 30, 2016 |
| Jan 11, 2016 | 38240441P | RESOLVE | CLASS - 2 | 59U15,68B07. NO TAG INDICATING DATE OF BRAKE MAINTENANCE, NO ENTRY OF BRAKE MAINTENANCE IN LOG. HI 1402105 AND 1402104 | $250 | $0 | May 19, 2016 |
| Dec 3, 2015 | 35047650H | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35146712H ISSUED ON 8/18/15 & TO FILE A C OF C PURSUANT TO 28-... | $0 | $0 | Apr 21, 2016 |
| Dec 3, 2015 | 35047549N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/ THE COMM'S ORDER CONTAINED IN NOV#35146711X ISSUED ON 08/18/15 & TO FILE A CERT OF CORRECTION PU... | $0 | $0 | Jan 21, 2016 |
| Oct 16, 2015 | 35046186Z | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35146712H ISSUED ON 8/18/15 & TO FILE A C OF C PURSUANT TO 28-... | $0 | $0 | Apr 21, 2016 |
| Oct 16, 2015 | 35046185R | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35146711X ISSUED ON 8/18/15 & TO FILE A C OF C PURSUANT TO 28-... | $0 | $0 | Mar 17, 2016 |
| Aug 18, 2015 | 35146711X | RESOLVE | CLASS - 1 | MULTIPLE DWELLING CONVERTED,MAINTAINED OR OCCUPIED W/3 OR MORE DWELLING UNITS THAN LEGALLY AUTHORIZED BY THE C OF O O... | $0 | $0 | Mar 3, 2016 |
| Aug 18, 2015 | 35146712H | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. WORK NOTED: CELLAR ERECTED FULL HEIGHT PARTITION WALLS TO CREAWTE ROOMS. ALSO NOTED: INSTALLED WAT... | $0 | $0 | Mar 3, 2016 |
| Aug 18, 2015 | 35164499R | RESOLVE | CLASS - 1 | WORK W/O A PERMIT. WORK NOTED: CELLARS ERECTED FULL HEIGHT PARTITION WALLS TO CREATE ROOMS. ALSO NOTED: INSTALLED WAT... | $1,600 | $0 | Nov 2, 2016 |
| Aug 18, 2015 | 35164498P | RESOLVE | CLASS - 1 | MULTIPLE DWELLING CONVERTED,MAINTAINED OR OCCUPIED W/3 OR MORE DWELLING UNITS THAN LEGALLY AUTHORIZED BY THE C OF O O... | $47,400 | $0 | Oct 20, 2016 |
| Dec 5, 2012 | 38224707N | RESOLVE | CLASS - 2 | 100B10,80M7,39I11,54H11,40P16. 100- PHONE IN CAR NOT WORKING. ALSO FANON TOP OF CAR NOT WORKING. | $0 | $0 | Jan 24, 2013 |
| Jan 6, 2012 | 38216421H | RESOLVE | CLASS - 2 | 45M13,51B01,05J01,32H11. 45- SEAL GOVERNOR ADJUSTING NUT. 51- ADJUST SLACK CABLE SWITCH TO BE MANUALLY RE-SETTING. 05... | $0 | $0 | Feb 23, 2012 |
| Jun 25, 2002 | 38123712P | RESOLVE | Non-Hazardous | 6Q3/46#2/50#1/57O2/74X11/ 6-CAR DOOR MOTOR CONTACT ON GUARD 46-HOIST CABLERED ROUGH CLEAN AND LUBRICATED 50 MAIN MACH... | $350 | $0 | Aug 8, 2002 |
| Oct 22, 1999 | 38091379R | RESOLVE | Non-Hazardous | 73X11-RESTORE TO PROPER WORKING ORDER. CALL FOR REINSPECTION. | $0 | $0 | Dec 9, 1999 |
| May 27, 1998 | 38075177Z | RESOLVE | Non-Hazardous | 15E28H30O46M47U48H60H74# 47-PERFORM 5 YEAR TEST 49-RESHACKLE CAR AND CCWT CABLES 74-NOISY OPERATION FROM MAIN MACHINE... | $350 | $0 | Jul 16, 1998 |
| Nov 19, 1997 | 38067002R | RESOLVE | Non-Hazardous | 35P14B 35-PROVIDE ACCESS TO MACHINE ROOM AND OVERHEAD. 14. PROVIDE CERTIFICATE OR NOTE WHERE TO BE FOUND. | $180 | $0 | Jan 22, 1998 |
| Oct 22, 1997 | 38066007L | RESOLVE | Non-Hazardous | 74#, 74-CEASE USE OF 1P900. PROVIDE CWT CLEARENCE. | $500 | $0 | Apr 30, 1998 |
| Jul 2, 1996 | 38056972Y | RESOLVE | Non-Hazardous | 29#A,46#B,74Q,35P,08V,17R.29#A-PROVID ERUN-BY 46#-RESHACKLE HOIST ROPES 74Q-PROVIDE FAN GUARD ON TOP OF CAR 17R-REMPV... | $200 | $0 | Sep 12, 1996 |
| Aug 5, 1992 | 38024748N | RESOLVE | Non-Hazardous | 08V,73O, | $0 | $0 | Dec 10, 1992 |
| Aug 7, 1991 | 38015799Z | RESOLVE | Hazardous | 22D,3M,28H,50Y,31R,73O,53B,31#,3 CAPACITY PLATE 31 TO FAN - WORK LIGHT 31 INSTALLED NEW ELEC METERS WITHOUT A PERMIT | $75 | $0 | May 14, 1992 |
| Dec 28, 1990 | 38003586R | RESOLVE | Non-Hazardous | 17B,74 PROVIDE ACCESS TAG GOVERNOR FOR 5YR TEST. 75 | $75 | $0 | Mar 7, 1991 |