ECB violations
304-306 West 150 Street, Manhattan • Block 02045 • Lot 0098
8 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jul 15, 2024 | 39530521R | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION, OBSERVED ACTIVE JOBSITE ONE SUSPENDED SCAFFOLD AT EXPOSURE 1. UPON REVIEWING APPROVED DRAWINGS... | $0 | $0 | Sep 19, 2024 |
| Jul 15, 2024 | 39530523K | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE WITH A SUSPENDED SCAFFOLD AT EXPOSURE 1. PLATFORM CONFIGURATION IS CONT... | $1,250 | $0 | Nov 7, 2024 |
| May 28, 2024 | 39529020K | RESOLVE | CLASS - 1 | OBSERVED SUSPENDED SCAFFOLDING IN USE @ EXPO1 OF JOBSITE. OUTRIGGER SYSTEM INSTALLED ON BULK HEAD WITH THREE FRAMES W... | $625 | $0 | Jan 2, 2025 |
| Mar 7, 2024 | 39526221N | RESOLVE | CLASS - 2 | AT TIME OF MY INSPECTION OBSERVED SUSPENDED SCAFFOLD INSTALLED AT ROOF/SETBACK -UPPON CHECKING PLANS SPLICING OF OUTR... | $625 | $0 | Jan 23, 2025 |
| Mar 7, 2024 | 39526220L | RESOLVE | CLASS - 2 | AT THE TIME OF MY INSPECTION OF 12 STORY NEW BUILDING OBSERVED 5 OUTRIGGER SUSPENDED SCAFFOLD INSTALLED AT ALL SITE-U... | $2,500 | $0 | Jan 23, 2025 |
| Jan 5, 2024 | 39524543R | RESOLVE | CLASS - 1 | AT TIME OF INSPECTION ON A NB AT 12 STORE WORK IN PROGRESS . REVIEW ON DOB NOW PERMIT #12105935 RENEW AN IN PROGRESS ... | $0 | $0 | Mar 14, 2024 |
| Jan 4, 2024 | 39524705K | RESOLVE | CLASS - 2 | EXP1 YODOCKS NOT COMPLY WITH MANUFACTURE SPECS REQUIRING FILLED WATER OR SAND AND MISSING LOCKING COUPLER CREATED HAZ... | $0 | $0 | Mar 21, 2024 |
| Jan 10, 2023 | 35670121R | RESOLVE | CLASS - 1 | FAILURE TO INSTITUTE/MAINTAIN EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION.AS NOTED:AT TIME OF INSPECTION OF ACTIVE J... | $1,250 | $0 | Apr 20, 2023 |