| Oct 27, 2025 | 39164933X | ACTIVE | CLASS - 1 | CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO... | $1,250 | $0 | Jan 8, 2026 |
| Jun 9, 2025 | 39150475K | ACTIVE | CLASS - 2 | EXP 1 AND 4 AREAS THAT HAVE BEEN PATCHED STARTING TO SHOW CRACKS IN STUCCO WITH PARTS MISSING BY SIDEWALK IN FRONT AN... | $500 | -$2,625 | Apr 7, 2026 |
| Feb 2, 2025 | 39137177X | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. PREMISES IS A SIX STORY M/D. SMALL SECTION OF STUCCO AT GROU... | $3,125 | $0 | Apr 10, 2025 |
| Aug 4, 2023 | 39091865Z | RESOLVE | CLASS - 1 | CLASS 1: CEASE USE: DOOR RESTRICTOR MISSING PLUNGER. INSTALL NEW PLUNGER & CONTACT NYCDOB FOR REINSPECTION (CU). CLAS... | $1,250 | $0 | Oct 12, 2023 |
| Jul 19, 2022 | 39066216Y | RESOLVE | CLASS - 2 | AT FRONT OF BUILDING,AT LEFT CORNER AND RIGHT CORNER CONCRETE BASE HAS CRACK AND SEPARATION, ALSO NOTED AT FRONT BASE... | $620 | $0 | Sep 8, 2022 |
| Apr 18, 2022 | 39060405X | RESOLVE | CLASS - 2 | FOUND EXPOSED WIRING, BODY DRAINS MISSING ON SAFETY RELIEF VALVES, BELT GUARD MISSING ON PUMP SET, GUARDS MISSING AT ... | $312 | $0 | Oct 7, 2022 |
| Dec 27, 2021 | 39053432X | ACTIVE | CLASS - 1 | DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMANS' SERVICE PRESENT IN THE ELEVATOR CONTROLLER. INSTALL FIREMANS' S... | $1,250 | $0 | May 26, 2022 |
| May 17, 2021 | 39041225P | RESOLVE | CLASS - 2 | OUTSIDE COMMUNICATION (PHONE) IN CAR FOUND NOT WORKING. REPAIR. CAT1 TAG IN THE ELEVATOR MACHINE ROOM FOUND EXPIRED. ... | $625 | $0 | Jan 13, 2022 |
| Apr 12, 2021 | 39039183N | ACTIVE | CLASS - 1 | CEASE USE ROCKMILLS MP150 BOILER, DUE TO CORRODED FLUE PIPE, DO NOT OPERATE BOILER UNTIL ALL HAZARDOUS CONDITION ARE ... | $1,250 | $0 | Mar 3, 2022 |
| Mar 2, 2021 | 39036968J | ACTIVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED INSTALL DLM AS PER 3.10.12 OF APPENDIX K3 REMEDY; PROVIDE AND INSTALL FIREMAN SERVICE, CLASS... | $1,250 | $0 | Mar 3, 2022 |
| Feb 10, 2021 | 39036065Z | RESOLVE | CLASS - 2 | PHONE IN CAR NOT WORKING. REPAIRED. NO MEANS OF ACCESS TO THE ELEVATOR MACHINE ROOM. PROVIDE MEANS OF ACCESS TO THE E... | $625 | $0 | May 13, 2021 |
| Feb 5, 2020 | 39016916J | ACTIVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $6,250 | $0 | Mar 18, 2021 |
| Nov 20, 2018 | 39000812Z | ACTIVE | CLASS - 1 | ON 11/20/2018 @ APPROX. 4:30 PM I OBSERVED AN ACTIVE GAS METER SUPPLYING GAS TO 5 COMMERCIAL GAS DRYERS WITHOUT ANY S... | $2,500 | $0 | Mar 21, 2019 |
| Nov 20, 2018 | 39000813K | ACTIVE | CLASS - 1 | ON 11/20/2018 @ APPROX. 4:30 PM I OBSERVED IN THE CELLAR 5 COMMERCIAL GAS DRYERS INSTALLED WITH GAS FLEXIBLE PIPING A... | $1,250 | $0 | Mar 21, 2019 |
| Nov 20, 2018 | 39000814M | ACTIVE | CLASS - 1 | ON 11/20/2018 @ APPROX. 4:30 PM I OBSERVED IN THE CELLAR 5 COMMERCIAL GAS DRYERS AND 5 WASHER MACHINES ALONG WITH GAS... | $2,500 | $0 | Mar 21, 2019 |
| Nov 20, 2018 | 39000815Y | ACTIVE | CLASS - 1 | ON 11/20/2018 @ APPROX. 4:30 PM I OBSERVED IN THE CELLAR 5 WASHER MACHINES ALONG WITH WATER/SANITARY PIPING AND FITTI... | $2,500 | $0 | Mar 21, 2019 |
| Nov 20, 2018 | 39000816X | ACTIVE | CLASS - 1 | ON 11/20/2018 @ APPROX. 4:30 PM I OBSERVED AN ACTIVE GAS METER SUPPLYING GAS TO 5 COMMERCIAL GAS DRYERS ALONG WITH GA... | $5,000 | $0 | Mar 21, 2019 |
| Nov 19, 2018 | 32096844H | ACTIVE | CLASS - 2 | 28B.50.FOUND ROCKMILLS BOILER MODEL 150 OPERATING WITH DEFECTS.(28B)TUBE LEAKING CAUSED BASE OF BOILER TO CORRODE (50... | $500 | $0 | Jan 10, 2019 |
| Jul 30, 2015 | 38237999R | RESOLVE | CLASS - 2 | 08V01,67B07,05J01,24M07,23M07. 08V01-CAR FLOOR TO LANDING SILL NOT LEVEL ADJUST 6TH FLR; 67B07-COMMUNICATION INSUFFIC... | $2,500 | $0 | Sep 17, 2015 |
| Mar 18, 2014 | 35090847P | RESOLVE | CLASS - 2 | WORK W/O A PERMIT.NOTED:@ GROUND FL COMMERCIAL SPACE OBSERVED FULL HEIGHT SHEETROCK PARTITIONS,CONNECTIONS OF WATER &... | $0 | $0 | May 8, 2014 |
| Feb 3, 2014 | 38230230X | RESOLVE | CLASS - 2 | 68M07,52Q03,42L10,100M07,05M07,42ZL10,40O02,97O02,05AM07,67M07. 68-MAINT LOG MISSING; 52G-GUARD CABLES; 42-MOUNT RELA... | $500 | $0 | Jun 12, 2014 |
| Aug 21, 2013 | 35021698L | RESOLVE | CLASS - 1 | SEC. EC 210.11C. NO 2 CIRCUITS PROVIDED FOR COUNTERTOP APTS STUDIO UNITS KITCHEN: NO TWO CIRCUITS PROVIDED AT THE COU... | $1,600 | $0 | Oct 10, 2013 |
| Aug 21, 2013 | 35021696H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ARC-FAULT CIRCUIT INTERRUPTED (AFCI) PROTECTION IN DWELLING UNITS. THE ENTIRE 35 APT UNITS: LIVING... | $1,200 | $0 | Oct 10, 2013 |
| Aug 21, 2013 | 35021695X | RESOLVE | CLASS - 1 | ELECTRICAL WORK W/O A PERMIT. THE ENTIRE 35 APTS: SUB PANELS, BRANCH CIRCUIT WIRING, RECEPTACLE OUTLETS, SWITCHES, LI... | $800 | $0 | Oct 10, 2013 |
| Aug 21, 2013 | 35021701N | RESOLVE | CLASS - 1 | SEC. EC 406.11. TAMPER-RESISTANT RECEPTACLES IN DWELLING UNITS. IN ALLONES SPECIFIED IN 210.52 ALL 125 VOLT,05 & 20 A... | $800 | $0 | Oct 10, 2013 |
| Aug 21, 2013 | 35021700L | RESOLVE | CLASS - 1 | SEC. EC 210.52(C) FAILURE TO PROVIDE RECEPTACLE OUTLETS EVERY (4') ALLSTUDIO APTS UNITS: OUTLET IS NOT PROVIDED EVERY... | $1,600 | $0 | Oct 10, 2013 |
| Dec 26, 2012 | 38224844J | RESOLVE | CLASS - 2 | 13M7,81M7,40P16,01B7,100M7. 100-PHONE IN CAR NEEDED.ALSO STOP SWITCH IN CAR MUST BE PUSH AND PULL, FIRE SERVICE PHASE... | $500 | $0 | Feb 14, 2013 |
| Jul 25, 2011 | 38216969N | RESOLVE | CLASS - 2 | 56Y13 56Y10 98BB05 21L10 16B01 08V01 29Q03. 56Y-REPAIR & SEAL GLOW PACKING. 21L-REPAIR DOOR LOCK ON ALL FLS. 16B-ADJU... | $250 | $0 | Sep 8, 2011 |
| Jun 8, 2010 | 38210463Z | RESOLVE | CLASS - 1 | 07X10,08V01. 07X- REPAIR DOOR REOPENING DEVICE C-USE ITEM TO LIFT CALLD-SMITH AT 212-566-5544 08- REPAIR LEVELING ON ... | $1,000 | $0 | Jul 29, 2010 |
| Mar 2, 2010 | 38209229M | RESOLVE | CLASS - 2 | 97/X/10,97-ONLY DEVICE IN BLDG,RETURN TO SERVICE | $250 | $0 | Apr 22, 2010 |
| Jul 18, 2009 | 38204591M | RESOLVE | CLASS - 2 | 08V10.10H11.60B7 08V10 FL STOPS NOT LEVEL ADJUST FLSTOP WERE NEEDED 10H11 CAR DOOR GIBS ARE WORN PROVIDE 17H11 HOISTW... | $0 | $0 | Sep 10, 2009 |
| Jul 8, 2009 | 38203916R | RESOLVE | CLASS - 2 | 08B1.17H10.70O2 08B01 FL STOPS ARE NOT LEVEL NEED TO BE ADJUSTED 12H11 SHAFT DOOR GIBS ARE WORN NEED TO BE REPLACED 1... | $0 | $0 | Aug 27, 2009 |
| Dec 9, 2008 | 38198880K | RESOLVE | CLASS - 2 | 05B10,16B10,60X10,42E10. 05B10-CAR DOOR INSUFFICIENT, SLAMMING,NEEDS REPAIR.16B10-HOISTWAY DOORS SLAMMING NEEDS REPAI... | $500 | $0 | Oct 15, 2009 |
| Nov 8, 2008 | 38193277N | RESOLVE | CLASS - 2 | 21D06.05B10.10H11.70O02.21D06 PROPERLY SECURE 2ND FL INTERLOCK COVER 05B10 REPAIR CAB DOOR FROM SLAMMING CLOSED CAUSI... | $500 | $0 | Jan 8, 2009 |
| Jun 23, 2008 | 38185904N | RESOLVE | Non-Hazardous | 65M07.40M07.08V01.64M07.66O02.59M07. 65M07 PROVIDE A PIT STOP SW. 40M07 M.R.DOOR MUST BE LABELED PROVIDE SIGNAGE 08V0... | $350 | $0 | Oct 15, 2009 |
| Sep 25, 2006 | 38161290L | RESOLVE | Hazardous | CEASE USE/HAZARDOUS.60G10,08J01,44U15.60-MAINLINE SWITCH ILLEGAL FUSE-CEASE USE-BEFORE RETURNING TO SERVICE CONTACT T... | $5,000 | $0 | Nov 9, 2006 |
| Dec 18, 2004 | 34452106R | RESOLVE | Hazardous | FAILURE TO PROVIDE AT LEAST 2 MEANS OF EGRESS FROM ROOM OR SPACE WHERE REQUIRED.NOTED:REAR OF BLDG IN QUESTION HAS FI... | $2,500 | $0 | Feb 3, 2005 |
| Dec 3, 2003 | 34407374K | RESOLVE | Hazardous | FAILURE TO MAINTAIN NOTED DEFECT:INSTALLATION OF NEW METAL ENTRY DOORSAND ASSOCIATED ATTACHED METAL WING PANELS NOTED... | $2,500 | $0 | Jan 22, 2004 |
| Nov 4, 2002 | 38135028R | RESOLVE | Non-Hazardous | 17M12-80B01-38I11-55L11 (80) ADJUST CAR DOOR TO OPEN FULL (17) REPLACE GIBS AT BASEMENT DOOR (38) REPAIR DOOR TO MACH... | $2,500 | $0 | Dec 19, 2002 |
| Aug 30, 2002 | 38125193L | RESOLVE | Non-Hazardous | 5L11-8V1-9H12-15L11-18Q3-16H12-22Y2-22L6-57O2-73U16. 5-L-11 SLAMS 15-L11 NOT SELF CLOSING 1 & 3 FLOOR 18-Q-3 2 FLOOR ... | $0 | $0 | Oct 17, 2002 |
| Nov 15, 2000 | 38109901N | RESOLVE | Non-Hazardous | 36I11,03D11,115H11.36-REPAIR MR.DOOR.03-PROVIDE GRILL FOR WORKING FARE15-REPAIR BASE DOOR. | $0 | $0 | Jan 4, 2001 |
| Apr 30, 1999 | 34212013P | ACTIVE | Non-Hazardous | OCCUPANCY CONTRARY TO DEPT OF BLDG RECORDS IN THAT ALT 100546928 DATED 3 19 93 STIPULATION INSTALLATION OF NEW METER ... | $2,500 | $0 | Jul 29, 1999 |
| Sep 26, 1995 | 38051453J | RESOLVE | Non-Hazardous | 03M,08V,02L,15L,16L,28L,35D,36I,37G,50Y,55X,57O,. 03M- FORM 02L- INAUDIBLE 15L- MAKE ALL DOORS SELFCLOSING 35D- LOIDDER. | $250 | $0 | Jan 25, 1996 |
| Aug 17, 1994 | 38043575H | RESOLVE | Non-Hazardous | 09H,15L,16H,08V,35D,35I,50Y,52I,74#,57Z,57O,,15L-MAKE ALL DOORS SELF-CLOSING 35D-SMOKE HOLE GRATING 35I-WALL 52I-DRUM... | $500 | $0 | Jan 26, 1995 |
| Sep 13, 1993 | 38037201M | RESOLVE | Non-Hazardous | 9H,16H,22D,28H,35W,46H,50Y,55X,58O,59O,75U,35I,39H,13M,14M,73O,74#,74Y35 WALL 74 ACCESS HOLE 74 TOP CAR. | $250 | $0 | Feb 17, 1994 |
| Feb 2, 1993 | 38031543P | RESOLVE | Non-Hazardous | 02L,09H,14L,15L,16H,22D,28L,35D,46L,50Y,50Y,50Y,52I,55X,57O,58O,59O,73#,75#,73#,18H, 02L-INAUOLIBLE 15LMAKE ALL DOORS... | $200 | $0 | Mar 18, 1993 |
| Jan 22, 1993 | 38031631P | RESOLVE | Non-Hazardous | 22D,14M,15P,50Y,73O,35D,13M,75#,15-HOLE 35-SADDER. | $5,000 | $0 | Mar 11, 1993 |
| Apr 22, 1992 | 38025024M | RESOLVE | Non-Hazardous | 08V,16H,22D,25Q,28L,30O,35D,46L,50Y,50Y,52L,57O,58O,59O,03O,73#,35-LADDER 03-EXCESS OIL FROM MACHINE IN CAB 73-PERFOR... | $5,000 | $0 | Jun 4, 1992 |
| Jun 15, 1991 | 38013527X | RESOLVE | Non-Hazardous | 22W,03O,73O,25Q,73#,03-0-02 OIL FROM MACHINE IN CAB. 73# PERFORM 5 YEAR TEST AND FILE TAG GOVERNOR. | $1,000 | $0 | Oct 10, 1991 |