| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 28, 2026 | 39194053P | ACTIVE | CLASS - 1 | PARTIAL OBSTRUCTION TO EGRESS, NOTED AT TIME OF INSPECTION OBSERVED AT EXPOSURE #1 THE GATES TO ACCESS FIRE ESCAPE AR... | $2,500 | $2,500 | Sep 3, 2026 |
| Jan 2, 2025 | 39134318R | RESOLVE | CLASS - 2 | CLASS 2: PHONE INOPERATIVE REAPIR & CONNECT SERVICE TO 24 HR EMERGENCY OPERATOR. CAR DOOR MISALIGNED CAUSING RUBBING/... | $1,562 | $0 | Mar 13, 2025 |
| Jan 2, 2025 | 39134319Z | RESOLVE | CLASS - 2 | CLASS 2: PHONE INOPERATIVE REPAIR & CONNECT SERVICE TO 24 HR EMERGENCY OPERATOR. SEASON HOIST ROPES & ADJUST CLIPS TO... | $1,562 | $1,562 | Mar 13, 2025 |
| Nov 22, 2024 | 35687087N | RESOLVE | CLASS - 1 | UNLAWFUL ACT FAILURE TO COMPLY WITH COMMISSIONER'S ORDER NOTE AT TIME OF INSPECTION OBSERVED MULTIPLE AC UNITS THIS W... | $6,250 | $6,250 | Feb 27, 2025 |
| Jun 28, 2024 | 39118053K | ACTIVE | CLASS - 2 | I OBSERVED IN THE BASEMENT MOUNTED AND INSTALLED NEXT TO THE MAIN ELECTRICAL SERVICE ONE TEMPORARY PANEL WITH BREAKER... | $4,000 | $4,000 | Sep 5, 2024 |
| Jan 16, 2024 | 37026284R | ACTIVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS INITIAL FACADES ... | $6,250 | $6,250 | Apr 18, 2024 |
| Sep 13, 2023 | 39094735Y | ACTIVE | CLASS - 1 | I OBSERVED IN CELLAR AREA GAS LEAK COMING FROM SHUT OFF VALVE ON MAIN RISER AT TIME OF INSPECTION WHICH CREATED A HAZ... | $6,250 | $6,250 | Apr 8, 2024 |
| Feb 12, 2022 | 35639685R | RESOLVE | CLASS - 2 | WORK WITHOUT PERMIT.AT TIME OF INSPECTION OF 6 STORY OCCUPIED BUILDING WITH SIDEWAKL SHED ERECTED AT EXP #1 REVIEW OF... | $1,250 | $0 | May 12, 2022 |
| Feb 11, 2022 | 39056013P | RESOLVE | CLASS - 2 | AT FRONT OF BUILDING INSTALLED APPROXIMATELY 100 LINEAR FEET OF SIDEWALK SHED WITHOUT PERMIT., OBTAIN ALL PERMITS | $1,250 | $0 | Mar 31, 2022 |
| Dec 10, 2021 | 35640481N | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS OR APPURTENANCES.NOTE:AT TIME OF INSPECTION OBSERVED AT EXP #1 WEST ELEVA... | $6,250 | $0 | Mar 10, 2022 |
| Nov 5, 2021 | 35632464L | RESOLVE | CLASS - 2 | WORK W/O PERMIT.NOTE:AT TIME OF INSPECTION OBSERVED SIDEWALK SHED IN PLACE WITHOUT PERMIT.REMEDY:COMPLY WITH CODE-OBT... | $1,250 | $0 | Feb 3, 2022 |
| Oct 29, 2021 | 35635540H | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.NOTED:BUILDING OWNER FAILED TO MAKE REPAIRS TO BUILDIN... | $25,000 | $0 | Jan 27, 2022 |
| Jul 14, 2021 | 35575489J | RESOLVE | CLASS - 2 | FAILURE TO OBTAIN PERMIT.AT TIME OF COMP INSPECTION AT 6 STORY OCCUPIED BUILDING I OBSERVED SIDEWALK SHED ERECTED UPO... | $3,125 | -$3,125 | Sep 30, 2021 |
| Jun 1, 2021 | 37021321Y | ACTIVE | CLASS - 2 | FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION EXTERIOR WALL ... | $1,250 | $0 | Oct 7, 2021 |
| May 25, 2021 | 39041708J | RESOLVE | CLASS - 1 | DOOR LOCK MONITORING IS NOT WORKING. REPAIR AND ADJUST. BRAKE TAG EXPIRED. PROVIDE. FIRE EXTINGUISHER TAG EXPIRED. PR... | $1,250 | $0 | Mar 17, 2022 |
| Jan 6, 2021 | 39034423K | ACTIVE | CLASS - 1 | I OBSERVED IN ILLEGAL LAUNDRY ROOM IN CELLAR GAS PIPING, FITTINGS AND VALVES IN CELLAR AND NO PERMITS ON FILE; THEREF... | $2,500 | $0 | Sep 30, 2021 |
| Jan 6, 2021 | 35547646X | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS ENCLOSURES CABLE ARMOR.SEVICE GROUND RACEWAYS N... | $600 | $0 | Oct 14, 2021 |
| Jan 6, 2021 | 39034425Y | ACTIVE | CLASS - 1 | I OBSERVED A LAUNDRY ROOM IN CELLAR MARKED ON DOOR LAUNDRY ROOM AND THE NECESSARY WATER, SANITARY, GAS PIPING, AND VE... | $2,500 | $0 | Sep 30, 2021 |
| Jan 6, 2021 | 39034424M | ACTIVE | CLASS - 1 | I OBSERVED IN CELLAR COMPACTOR ROOM SPRINKLER PIPING THAT WAS INSTALLED OFF OF DOMESTIC WATER LINE AND BOTH SPRINKLER... | $1,250 | $0 | Sep 30, 2021 |
| Jan 6, 2021 | 35547645Y | RESOLVE | CLASS - 1 | UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE.DEFECTIVE S... | $1,600 | $0 | Oct 14, 2021 |
| Jan 6, 2021 | 35547647H | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE COVER FACE PLATE LAMPHOLDER LUMINAIRE CANOPY FOR ELECTRICAL OUTLET.SPLICE BOX COVERS MISSING IN BA... | $250 | $0 | Jul 8, 2021 |
| Jan 6, 2021 | 39034421R | ACTIVE | CLASS - 1 | I OBSERVED IN CELLAR ILLEGAL LAUNDRY ROOM GAS PIPING, FITTING AND VALVES INSTALLED AND WORK WAS 100 PERCENT COMPLETED... | $2,500 | $0 | Sep 30, 2021 |
| Jan 6, 2021 | 35547643K | RESOLVE | CLASS - 1 | ELECTRICAL WORK WITHOUT PERMIT.OBSERVED AT 850AM BRANCH CIRCUIT WIRINGINSTALLED FOR FIXTURES OUTLETS SWITCHES IN APAR... | $800 | $0 | Oct 14, 2021 |
| Jan 6, 2021 | 35547644M | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE ARE FAULT CIRCUIT INTERRUPTER(AFCI)PROTECTION IN DWELLING UNITS.NO AFCI PROTECTION PROVIDED FOR BR... | $1,200 | $0 | Jul 8, 2021 |
| Jan 6, 2021 | 39034426X | ACTIVE | CLASS - 1 | I OBSERVED IN ILLEGAL LAUNDRY ROOM GAS PIPING, FITTINGS AND VALVES INSTALLED WITH GAS FLEX CONNECTORS AND NOT CONNECT... | $1,250 | $0 | Sep 30, 2021 |
| Jan 6, 2021 | 39034420P | ACTIVE | CLASS - 1 | I OBSERVED IN CELLAR LAUNDRY ROOM AREA GAS PIPING INSTALLED AND NO PERMITS ON FILE, THEREFORE NO PROPER TESTING WAS P... | $5,000 | $0 | Sep 30, 2021 |
| Jun 29, 2020 | 37019523J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35458115M ISSUED ON 10-17-2019, AND TO FIL... | $1,250 | $0 | Mar 4, 2021 |
| Oct 17, 2019 | 35458115M | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURENTANCES AS NOTED.EXPOSURE 1 SPALLED BRICKS,STEP CRACKS DAMAGED... | $2,530 | $0 | Jan 2, 2020 |
| Oct 7, 2014 | 38232640H | RESOLVE | CLASS - 2 | 5J1,10B7,16H10,21D6,42G9,45H10,58H10,100BB7. 5J1-GAP AT CAR DOOR; 10B7-ONE GIB MISSING,PROVIDE; 16H10-3RD FLR HOISTWA... | $0 | $0 | Dec 11, 2014 |
| Sep 15, 2014 | 38233227Z | RESOLVE | CLASS - 2 | 59L10,52Q03,61L11,16L10,100L10,40L10,05M07,100M07,15M07. 59-WIREST O COIL; 52-CABLE GUARDS; 61-MACHINE DISCONNECTED; ... | $250 | $0 | Oct 30, 2014 |
| Jul 1, 2014 | 38231707Z | RESOLVE | CLASS - 2 | 100L11,52M03,44#11,56L10,40O02,40AL10,61L11,100L10,15M07,100-FIRE EXT ,52-GUARDS,44-DRIVE SHEAVE,56-(STRESS)WORSE,40-... | $250 | $0 | Aug 21, 2014 |
| Jul 1, 2014 | 38231706R | RESOLVE | CLASS - 2 | 100L06,52M07,44H11,59L10,40O02,100AM07,61L11,68M07,56M07,15M07,100-TOEGUARD,52-CABLE GUARDS,44-SHEAVE,59-WIRES & CONN... | $250 | $0 | Aug 21, 2014 |
| Jun 9, 2014 | 35087396H | RESOLVE | CLASS - 2 | WORK W/O PERMIT. NOTE : AT THE TIME OF MY INSP. AT APT 46A WORK BE DO ING TAKING DOWN WALL IN THE BATHROOM AND THROUG... | $400 | $0 | Jul 24, 2014 |
| Mar 26, 2014 | 35066143R | ACTIVE | CLASS - 1 | FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.@ TIME OF INSP IOBSERVED WASHERS & GAS DRYERS INSTALLED IN BASE... | $1,000 | $0 | Nov 3, 2014 |
| Mar 26, 2014 | 35066142P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER REINSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC10... | $500 | $0 | Nov 3, 2014 |
| Mar 26, 2014 | 35066141N | ACTIVE | CLASS - 1 | WORK W/O A PERMIT.@ TIME OF INSP I OBSERVED WASHERS & GAS DRYERS INSTALLED IN BASEMENT W/NO PERMITS OR INSPECTIONS ON... | $1,600 | $0 | Nov 3, 2014 |
| Mar 30, 2012 | 38221377X | RESOLVE | CLASS - 2 | 08V01,56Y13,67M07,68B07,76M07.(67M07)PROVIDE COMMUNICATIONS IN CAR (TELEPHONE).(68B07)PROVIDE UPDATED MAINTAINACE LOG... | $0 | $0 | May 17, 2012 |
| Jan 25, 2008 | 38181435L | RESOLVE | Non-Hazardous | 41G11,55Y02,59Q03,10M07,66O02,64M07,65M07,83##,83#01,38O02,84#10.83#/#-PROVIDE CABLE SPINOUTS FOR CAR & CWT.83#/01-EL... | $0 | $0 | Mar 13, 2008 |
| Jan 25, 2008 | 38181434J | RESOLVE | Non-Hazardous | 55Y02,66Z09,64M07,25#06,38O02,16#10,59Q03,16XX,83#01.25#/06-PROPERLY SECURE STOP OF CAR ESCAPE HATCH.16#/10-SWING HAT... | $0 | $0 | Mar 13, 2008 |
| Jun 28, 2006 | 34527387X | RESOLVE | Hazardous | FAILURE TO MAINTAIN.DEFECTS NOTED:AT FRONT OF PREMISES NORTH WEST CORNER THERE ARE CRACKS:ONE DIAGONAL AND ONE VERTIC... | $800 | $0 | Jul 12, 2007 |
| Jun 6, 2006 | 38159703H | RESOLVE | Non-Hazardous | 8V1/31H11/39D6/55Y13/58B1/44#10/38M7/66O23/51O2 8-V-1- ADJUST LEVELING31-H-11-REPLACE WORN GUIDE SHOES 39-D-6- PROPER... | $180 | $0 | Jul 27, 2006 |
| May 22, 2006 | 38158965N | RESOLVE | Non-Hazardous | 16L10/08J01/21J01/56Y13. 16-PROVIDE ELEV. SERVICE TO 6TH FLR. 08-ADJUST 21-ADJUST WHEREVER NECESSARY (ELEV. STOPS WHE... | $180 | $0 | Oct 3, 2006 |
| Jan 13, 2005 | 38156769R | RESOLVE | Non-Hazardous | 10M7/44E10/66O2/84## 10)PROVIDE ADDITIONAL CAR DOOR GIB 44)ELIMINATE EXCESSIVE NOISE 66)CLEAN 84)PROVIDE LIGHT CAR TOP | $2,500 | $0 | Mar 3, 2005 |
| Nov 6, 2004 | 38149919H | RESOLVE | Hazardous | 16M7 CEASE USE 16-L FLOOR DOOR MISSING PROVIDE. TO LIFT CEASE USE CALLS. MASTER 212 566-5544 | $2,500 | $0 | Dec 23, 2004 |
| Aug 8, 2003 | 34409209X | RESOLVE | Hazardous | FAILURE TO MAINTAIN DEFECT NOTED: THE 1'-0" HIGH X 2'-0"THICK CONCRETE WALL IS CRACKED APPROX 4'-0" LONG X 1 1/2" OPE... | $2,500 | $0 | Sep 25, 2003 |
| Aug 8, 2003 | 34409207M | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL. DEFECTS NOTED: VARIOUS SECTIONS OF COURSE RUBBLE BASEMENT WALLS ARE PEAKI... | $2,500 | $0 | Sep 25, 2003 |
| Aug 8, 2003 | 34409208Y | RESOLVE | Hazardous | EXIT PASSAGEWAY OR ORRIDOR: TOTAL OBSTRUCTION. OBSTRUCTION NOTED: THE SOUTH FIRE ESCAPE DROPPER LADDER OBSTRUCTED WIT... | $2,500 | $0 | Sep 25, 2003 |
| Jan 29, 2003 | 38135786X | RESOLVE | Non-Hazardous | 03M07-08V01-18A12-19L11-23L06-32Q03-24U16-37O02-48B15-49B15-81U05. 3M7 - CAPACITY PLATE. 18A12 - NOT WIRE GLASS. 19L1... | $2,500 | $0 | Mar 20, 2003 |
| Jan 29, 2003 | 38135787H | RESOLVE | Non-Hazardous | 08V01-10H12-23L06-23Y02-24U16-37O02-41H11-49B15-52Y02-62Z09-81U05. 23L06 - TO CODE. 23Y02 - CAR TOP. 24U16 - 5 YRS TE... | $2,500 | $0 | Mar 20, 2003 |
| Dec 10, 2002 | 38133754M | RESOLVE | Non-Hazardous | 08V01-19L11-23L06-23Y02-31Y02-37Y02-52Y11-62O02-81U05-24U16. 19L11 - STOP CAR IN FLIGHT WHEN 3RD FL DOOR IS PULLED. 2... | $350 | $0 | Jan 30, 2003 |