Maintenance code violations
334 Convent Avenue, Manhattan • Block 02059 • Lot 0017
306 records
HPD grades a violation A for non-hazardous through C for immediately hazardous.
| Issued | Class | Status | Violation | Apartment | Correct by |
|---|---|---|---|---|---|
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE REFIT ENTRANCE DOOR. AT COMMUNITY BATHROOM, 3rd STORY | — | May 23, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 12, 3r... | 12 | Feb 23, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE REFIT DOOR TO FRAME IN THE ENTRANCE LOCATED AT APT 12, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | 12 | May 23, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT 13, 3r... | 13 | Feb 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 13, 3rd STORY,... | 13 | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED A... | 13 | Mar 24, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE REFIT WOOD DOOR LOCATED AT B-ROOM 12, 3rd STORY, 1st B-ROOM FROM EAST AT SOUTH | 12 | May 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WAL... | 12 | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE 1st ROOM FROM EAST AT SOUT... | 12 | Mar 24, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Feb 23, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS AT COM... | — | May 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT ALL WALLS... | — | Mar 24, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS AT PUB... | — | May 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Mar 24, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE EAST YARD | — | May 23, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS AT PUB... | — | May 23, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | May 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE , DEFECTIVE LOCK AT ENTRANCE DOOR LOCATED AT B-ROOM UNIT13... | UNIT13 | Mar 24, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE UNHINGEDE DOOR AT ENTRANCE LOCATED AT B-ROOM 12, 3rd STORY, 1st B-ROOM F... | 12 | Feb 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WOOD BALISTERS AT PUBLIC HALL STAIRS, 1st STORY | — | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE WASH BASIN AT COMMUNITY BATHROOM, 3rd STORY | — | Mar 24, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MORTISE LOCK AT DOOR IN THE 1st ENTRANCE FROM EAST LOCATE... | 13 | Feb 23, 2021 |
| Feb 17, 2021 | C | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE METAL CHIMNEY AT ROOF | — | Feb 23, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT COMMUNITY BATHROOM, 2nd STORY | — | Feb 23, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED AT BOILER ROOM | — | Feb 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MORTAR CEMENT AT SOUTH WALL AT ROOF | — | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Mar 24, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS AT... | — | May 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Mar 24, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS AT... | — | May 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR AT COMMUNITY BATHROOM ... | — | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING TWO BALLUSTERS AT PUBLIC HALL STAIRS HAND RAIL , 3rd STORY | — | Mar 24, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ALL STORIES AT PUBLIC HALL | — | May 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING A... | — | Mar 24, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS AT... | — | May 23, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | May 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF STORED BICYCLES AT BOILER ROOM | — | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT STOVE IN THE ROOM LOCATED AT B-ROOM 9, 2nd ST... | 9 | Mar 24, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ROOM LOCATED AT B-ROOM 9, 2nd STORY, 1st B-ROOM... | 9 | Feb 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE 1st ROOM FROM EAST AT NORT... | 12 | Mar 24, 2021 |
| Feb 17, 2021 | C | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE KEY OPERATED MORTISE LOCK IN THE ENTRANCE LOCATED AT APT 1... | 13 | Feb 23, 2021 |
| Feb 17, 2021 | B | VIOLATION WILL BE REINSPECTED | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE UPPER AND LOWER WINDOW PANE AT COMMUNITY BATHROOM, 3rd STORY | — | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT BULK HEAD CEILING AT PUBLIC HALL, 4th STORY | — | Mar 24, 2021 |
| Feb 17, 2021 | C | VIOLATION DISMISSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AT PUBLIC HALL, 3rd STORY | — | Feb 23, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER AND PAINT AT ALL WALLS AND C... | — | Mar 24, 2021 |
| Feb 17, 2021 | B | NOV SENT OUT | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PAINT AND STUCCO AT FACADE AT FRONT ... | — | Mar 24, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 27-2005 ADM CODE REFIT DOOR AT APARTMENT ENTRANCE IN THE ENTRANCE LOCATED AT APT 12, 3rd STORY, 1st APARTMENT FROM ... | 12 | May 23, 2021 |
| Feb 17, 2021 | A | NOV SENT OUT | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE ... | — | May 23, 2021 |