| Oct 20, 2020 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PARTITIONS WITH DOOR AND SLIDE BOLT AT ROOF, CAPABL... | — | Oct 26, 2020 |
| Oct 19, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT PUBLIC HALL, 5th STORY | — | Nov 23, 2020 |
| Oct 19, 2020 | A | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT NORTH AND WEST WALL... | 23 | Jan 22, 2021 |
| Feb 13, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING ASSEMBLY AT ROOF DOOR | — | Mar 19, 2020 |
| Feb 13, 2020 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FREE STANDING RADIATOR PRESENT AT PUBLIC HALL, 3rd ... | — | Feb 21, 2020 |
| Feb 13, 2020 | C | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 31, 3rd STORY, 1s... | 31 | Mar 5, 2020 |
| Feb 12, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 31 | Mar 18, 2020 |
| Feb 12, 2020 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 31 | Feb 20, 2020 |
| Feb 12, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILI... | 31 | Mar 18, 2020 |
| Feb 12, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE WALLS IN THE BATHROOM L... | 31 | Mar 18, 2020 |
| Feb 12, 2020 | C | VIOLATION WILL BE REINSPECTED | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 31, 3rd STO... | 31 | Mar 4, 2020 |
| Feb 12, 2020 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING ASSEMBLY TO ENTRANCE DOOR IN THE 5th ROOM FROM EAS... | 31 | Mar 18, 2020 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| Feb 11, 2019 | C | VIOLATION CLOSED | § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 33, 3r... | 33 | Feb 10, 2019 |
| Feb 11, 2019 | C | VIOLATION CLOSED | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIG... | — | Feb 19, 2019 |
| Feb 11, 2019 | C | VIOLATION CLOSED | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED. AT BASEMENT | — | Feb 19, 2019 |
| Oct 25, 2018 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS AND CEILING IN ... | 31 | Jan 28, 2019 |
| Oct 25, 2018 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE... | 31 | Jan 28, 2019 |
| — | I | VIOLATION DISMISSED | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27... | — | — |
| May 31, 2018 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOC... | 23 | Jul 5, 2018 |
| May 31, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM ... | 23 | Jul 5, 2018 |
| May 31, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 1st ROOM FR... | 23 | Jul 5, 2018 |
| May 31, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LO... | 23 | Jul 5, 2018 |
| May 31, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST... | 23 | Jul 5, 2018 |
| Apr 12, 2018 | C | VIOLATION CLOSED | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED WIRING AT... | — | Apr 20, 2018 |
| Apr 12, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT CEILING AND WALL, AT ... | — | Apr 20, 2018 |
| Apr 12, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT CEILING AT BOILER ROOM | — | Apr 20, 2018 |
| Apr 12, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT CEILING AT CELLAR | — | Apr 20, 2018 |
| Apr 12, 2018 | C | VIOLATION CLOSED | § 12 M/D LAW DISCONTINUE THE STORAGE OF COMBUSTIBLE MATERIAL GRILL WITH PROPANE ,AT ROOF | — | Apr 20, 2018 |
| Apr 12, 2018 | C | VIOLATION CLOSED | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE... | — | Apr 20, 2018 |
| Apr 12, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ASPHALT AT FLASHING , NORTH PARAPET ... | — | May 17, 2018 |
| Apr 12, 2018 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILINGS AND WALLS , ALL STO... | — | Jul 16, 2018 |
| Apr 12, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE THE 2ND WOOD TREAD FROM BOTTOM, AT PUBLIC HALL STAIRS, 2nd STORY | — | May 17, 2018 |
| Apr 12, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT PUBLIC HALL, 5th STORY | — | May 17, 2018 |
| Apr 12, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE STUCCO CEMENT AT EXTERIOR WALL, FROM... | — | May 17, 2018 |
| Apr 12, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS TO ROOF, BULKHEAD AT PUBLIC HALL, 5th STORY | — | May 17, 2018 |
| Mar 22, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS I... | 23 | Apr 26, 2018 |
| Mar 22, 2018 | A | VIOLATION CLOSED | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILINGS AND WALLS THROUGHOU... | 23 | Jun 25, 2018 |
| Mar 22, 2018 | B | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING, HALL WAY AT BASE... | — | Apr 26, 2018 |
| Mar 22, 2018 | B | VIOLATION CLOSED | § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN THE ENTRANCE LOCATED AT APT 23, 2nd STORY, 1st AP... | 23 | Apr 26, 2018 |
| Mar 22, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDON SASH, NORTH WALL IN THE 5t... | 23 | Apr 26, 2018 |
| Mar 22, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR OVER CEILING IN THE... | 51 | Apr 26, 2018 |
| Mar 22, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 5th STORY | — | Mar 30, 2018 |
| Mar 22, 2018 | B | VIOLATION CLOSED | § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE IN THE ENTIRE APARTMENT LOCAT... | 21 | Apr 26, 2018 |
| Mar 22, 2018 | C | VIOLATION CLOSED | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK OVER CEILING IN THE 1st ROOM F... | 21 | Mar 30, 2018 |
| Mar 22, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 4th ROOM FROM EAST LOCATED AT APT 51,... | 51 | Mar 30, 2018 |
| Mar 22, 2018 | B | VIOLATION CLOSED | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT PLASTER CEILING, AT P... | — | Apr 26, 2018 |
| Mar 22, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY ENTRY DOOR LOCK AT DOOR LEADING TO FIRE ESCAPE ... | 23 | Mar 30, 2018 |
| Mar 22, 2018 | C | VIOLATION CLOSED | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM EAST LOCATED AT APT 51,... | 51 | Mar 30, 2018 |
| Mar 22, 2018 | A | VIOLATION CLOSED | § 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ON WALL, ALL STORIES AT PUBLIC HALL | — | Jun 25, 2018 |