ECB violations
469-473 West 159 Street, Manhattan • Block 02109 • Lot 0017
8 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jan 27, 2026 | 39175052J | RESOLVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED SIDE WALK SHED UNDER ACTIVE PERMIT # M01320584-I1-SH WITH NO VISUAL PARAPET SIGN AFFIX... | $1,250 | $1,250 | May 7, 2026 |
| Nov 13, 2025 | 39166827L | ACTIVE | CLASS - 1 | 5 STORY NFP MD CORNER BUILDING. WITH VERTICAL STEP CRACKS THAT LEAD FROM THE FIFTH FLOOR TO PARAPET WALL. AT EXP 1 & ... | $2,500 | $2,500 | Sep 22, 2026 |
| Feb 1, 2002 | 34315955K | RESOLVE | Hazardous | FAILURE TO MAINTAIN BUILDING(INTERIOR). NOTED: DEFECTS ARE IN BASEMENT APT WEST 159 ST APPROX 1/2" CRACK IN MASONRY W... | $2,500 | $0 | Mar 21, 2002 |
| Apr 22, 1992 | 34071267Z | ACTIVE | Hazardous | FAILURE TO MAINTAIN-PLASTER NEAR SKYLIGHT ROOF LEVEL MISSING. REMEDY=REPAIR PLASTER | $5,000 | $0 | Jul 2, 1992 |
| Aug 16, 1989 | 34031479Y | ACTIVE | Hazardous | FAILURE TO MAINTAIN MORTAR JOINTS ERODED SOUTH SIDE WALL REMEDYREPOINT MORTAR JOINTS | $1,000 | $0 | Oct 6, 1989 |
| Aug 16, 1989 | 34031480L | ACTIVE | Hazardous | FAILURE TO MAINTAIN STORAGE OF COMBUSTABLE MATERIALS ON ROOF.. REMEDYREMOVE COMBUSTABLE MATERIALS | $1,000 | $0 | Oct 6, 1989 |
| Aug 16, 1989 | 34031481N | ACTIVE | Hazardous | FAILURE TO MAINTAIN PLASTER NEAR SKYLIGHT ROOF LEVEL MISSING REMEDY REPAIR PLASTER | $1,000 | $0 | Oct 6, 1989 |
| Aug 16, 1989 | 34031478M | ACTIVE | Non-Hazardous | FAILURE TO MAINTAIN 1 ENTRANCE DOOR BROKEN 2 DOOR HARDWARE MISSING. REMEDY REPAIR ENTRY DOOR AND REPLACE HARDWARE ON ... | $500 | $0 | Oct 6, 1989 |