ECB violations
2129-2133 Amsterdam Avenue, Manhattan • Block 02111 • Lot 0050
59 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Jun 22, 2026 | 39555750L | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OF 6 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE NOT MAINTAINED PER CODE 1. MISSING APPROXIM... | $2,400 | $2,400 | Aug 27, 2026 |
| Jun 22, 2026 | 39555748M | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OF 6 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE WITHOUT INFORMATION PANEL ON PARAPET CAUSIN... | $1,250 | $1,250 | Aug 27, 2026 |
| Jun 22, 2026 | 39555749Y | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OF 6 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH PERMIT M08039557 EXPIRED 5-1-24 CAUSIN... | $1,250 | $1,250 | Aug 27, 2026 |
| Jan 29, 2026 | 39175261X | ACTIVE | CLASS - 3 | WEILMCLAIN BOILER HAS JUNK ON+AROUND THE OIL TANK+THERE IS A WASTE PIPE LEAKING INTO BOILER ROOM;CORRECT VIOLATION+SU... | $500 | $500 | Mar 11, 2027 |
| Jan 28, 2026 | 39175235M | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED A SIDE WALK SHED WITH EXPIRED PERMIT ( M08039557) ON DOB RECORDS ., RENEW PERMIT | $1,280 | $1,280 | Mar 22, 2027 |
| Jan 28, 2026 | 39175237X | ACTIVE | CLASS - 1 | AT TIME OF INSPECTION AN UNDOCUMENTED/UNPREMITTED CLASS A APT WAS OBSERVED IN BASEMENT. THIS UNIT WAS SUPPLYING ELECT... | $12,500 | $12,500 | May 7, 2026 |
| Jan 28, 2026 | 39175233Z | ACTIVE | CLASS - 2 | AT TIME OF INSPPECTION OBSERVED UNDOCUMENTED/UNPREMITTED CLASS A APT IN BASEMENT, WALLS WERE BUILT TO CREATE SEPARATI... | $6,250 | $6,250 | May 7, 2026 |
| Jan 28, 2026 | 35485263H | ACTIVE | CLASS - 2 | OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O AND DEPARTMENT OF BUILDINGS RECORDS. ILLEGAL CELLAR APARTMENT WITH PARTI... | $1,250 | $1,250 | Aug 20, 2026 |
| Jan 28, 2026 | 39175236Y | ACTIVE | CLASS - 1 | AT TIME OF INSPECTION OBSERVED AN UNDOCUMENTED/UNPREMITTED CLASS A APT IN BASEMENT CONSIST OF: KITCHEN, BATHROOM, LIV... | $12,500 | $12,500 | May 7, 2026 |
| Jan 28, 2026 | 39175234K | ACTIVE | CLASS - 2 | AT TIME OF INSPECTION OBSERVED UNDOCUMENTED/UNPREMITTED CLASS A APT IN BASEMENT A KITCHEN SINK AND 3PC BATHROOM ( STA... | $6,250 | $6,250 | May 7, 2026 |
| Apr 3, 2025 | 39143738H | ACTIVE | CLASS - 1 | CLASS 1: UPON INSPECTION FOUND ELEVATOR TO BE OUT OF SERVICE. RETURN ELEVATOR TO SERVICE IMMEDIATELY AS PER 1RCNY 11-02. | $1,250 | $0 | Jun 12, 2025 |
| Feb 1, 2024 | 39104986P | ACTIVE | CLASS - 1 | ENTIRE DEVICE IS SHUT DOWN. NEED TO REPAIR AND RE-INSPECTION REQUIRED. NO ACCESS TO MOTOR ROOM AT TIME OF INSPECTION,... | $1,250 | $1,250 | Apr 11, 2024 |
| Nov 13, 2022 | 39073792H | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. BUILDING FACADE IN STATE OF DISREPAIR WITH A PARTIALLY COLLA... | $6,250 | $6,250 | Dec 29, 2022 |
| Mar 18, 2022 | 35568043J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39044329N ISSUED ON 07/13/21 & TO FILE A... | $0 | $0 | Jun 16, 2022 |
| Mar 2, 2022 | 35568039R | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39043937M ISSUED 7/2/21 AND FILE CERTIFIC... | $0 | $0 | Jun 2, 2022 |
| Jan 28, 2022 | 39055088P | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED EXHAUST FAN (CENTRIFUGAL FAN) PRESENT ON ROOFTOP SERVICI... | $625 | $625 | Jun 2, 2022 |
| Jan 14, 2022 | 35567913J | RESOLVE | CLASS - 2 | FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#39044329N ISSUED ON 07/13/21 & TO FILE A CERT OF CORREC... | $0 | $0 | Apr 14, 2022 |
| Dec 17, 2021 | 35565465X | RESOLVE | CLASS - 1 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39043937M ISSUED ON 7/2/2021 AND TO FI... | $2,500 | $2,500 | Mar 17, 2022 |
| Dec 6, 2021 | 39052256L | ACTIVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371 ... | $625 | $625 | Jan 20, 2022 |
| Nov 24, 2021 | 35566090N | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39044329N ISSUED ON 7/3/2021 AND TO FI... | $1,250 | $1,250 | Feb 24, 2022 |
| Nov 17, 2021 | 35315745Z | ACTIVE | CLASS - 1 | WORK WITHOUT PERMIT WORK NOTED:IN APT 436353 PLUMBING FIXTURES FROM BATHROOM AND KITCHEN WERE REMOVED WITH NO DOB PER... | $2,500 | $0 | Feb 17, 2022 |
| Nov 17, 2021 | 35634338J | RESOLVE | CLASS - 2 | ELECTRICAL WORK W/OUT A PERMIT.OBSERVED AT 9AM ELECTRICAL WIRING REMOVED IN APARTMENTS #43,53,& 63.NO APPLICATION ON ... | $800 | $0 | Feb 24, 2022 |
| Nov 17, 2021 | 35576937Z | RESOLVE | CLASS - 1 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING.NOTE:AT TIME OF INSPECTION OBSERVED EXCESSIVE AMOUNTS OF STORED DEBRIS,COMB... | $2,500 | $2,500 | Feb 17, 2022 |
| Nov 17, 2021 | 35315746K | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:WORK NOTED UNDERAPPLICATION LAA DOB 140154801.FOR THE WORK DONE... | $1,250 | $1,250 | Feb 17, 2022 |
| Nov 17, 2021 | 35315747M | ACTIVE | CLASS - 1 | FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:OBSERVED IN APT 23 DRYER HOOKED UP IN A UNSAFE MANNER.VENT NOT ... | $1,250 | $1,250 | Feb 17, 2022 |
| Nov 17, 2021 | 35634336X | ACTIVE | CLASS - 2 | FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS ENCLOSURES CABLE ARMOUR.LIGHTING RACEWAY OVER MAIL... | $600 | $600 | Feb 24, 2022 |
| Nov 17, 2021 | 35634337H | ACTIVE | CLASS - 2 | FAILURE TO SECURE SUPPORT RACEWAYS CABLE ASSEMBLIES BOXES CABINETS FITTINGS.FIXTURE OVER DOOR ENTRANCE NOT PROPERLY S... | $400 | $400 | Feb 24, 2022 |
| Nov 17, 2021 | 35634339L | ACTIVE | CLASS - 1 | UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARATUS APPLIANCES MATERIALS OR WIRING IN USE.EXPOSED ELE... | $1,600 | $1,600 | Feb 24, 2022 |
| Oct 27, 2021 | 35563644M | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V39043937M ISSUED 7/2/21 &TO FILE C/C PURSUANT TO28-201... | $0 | $0 | Jun 2, 2022 |
| Sep 30, 2021 | 35535555M | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39044329N ISSUED 7/13/21 AND FILE CERTIFI... | $0 | $0 | May 5, 2022 |
| Sep 28, 2021 | 39048332M | ACTIVE | CLASS - 2 | FOUND CAT1 TAG IN THE ELEVATOR MACHINE ROOM EXPIRED. PERFORM CAT1 TEST AND PROVIDE CAT1 TAG IN THE ELEVATOR MACHINE R... | $312 | $0 | Nov 18, 2021 |
| Sep 16, 2021 | 35562603L | RESOLVE | CLASS - 1 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V39043937M ISSUED 7/2/21 &TO FILE C/C PURSUANT TO28-201... | $2,500 | $2,500 | Apr 28, 2022 |
| Aug 20, 2021 | 35561640X | RESOLVE | CLASS - 2 | FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#39044329N ISSUED ON 07/13/21 AND TO FIL... | $1,250 | $1,250 | Apr 7, 2022 |
| Jul 13, 2021 | 39044329N | RESOLVE | CLASS - 1 | UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. AT TIME OF INSPECTION (6) PERSONS PRESENT IN APT #63 ... | $5,000 | $0 | Sep 2, 2021 |
| Jul 2, 2021 | 39043937M | RESOLVE | CLASS - 1 | WORK WITHOUT A PERMIT. FULL GUT DEMOLITION TAKING PLACE IN APARTMENT #43, 53 AND 63. REMOVAL OF ALL FIREPROOF MATERIA... | $2,500 | $0 | Aug 26, 2021 |
| Feb 4, 2021 | 39035849M | RESOLVE | CLASS - 2 | PROVIDE ACCESS TO MOTOR ROOM | $0 | $0 | Dec 2, 2021 |
| Oct 27, 2020 | 39031085N | ACTIVE | CLASS - 1 | OUT SIDE COMM INOPERATIVE REPAIR, HOIST ROPE WORN RESCHAKLE, DRUM TO COUNTERWEIGHTS ROPE WORN RESCHACKLE ,BRAKE TAG M... | $1,250 | $1,250 | Dec 17, 2020 |
| Sep 10, 2020 | 39028381K | ACTIVE | CLASS - 2 | RESHACKLE TAG EXPIRED (FROM 2/2018). PHONE INSIDE CAR INOPERATIVE, BRAKE MAINTENANCE TAG EXPIRED. | $625 | $625 | Oct 29, 2020 |
| Aug 28, 2019 | 38271107L | ACTIVE | CLASS - 2 | 2.X.10,39.O.2,70.O.2,99.BB.7=2-X-10 OUTSIDE COMM INOPERATIVE REPAIR 39-O-2 CAR TOP DIRTY CLEAN 70-O-2 DIRTY CLEAN 99-... | $3,125 | $3,125 | Oct 31, 2019 |
| Jul 1, 2019 | 38270232X | ACTIVE | CLASS - 2 | 2X10,11L10,68B7,70O2;2-X-10 OUTSIDE COMMUNICATION INOPERATIVE/11-L-10 CAR STATION DEFECTIVE,WHEN MULTIPLE CALLS ARE P... | $3,125 | $3,125 | Aug 29, 2019 |
| Nov 6, 2017 | 38259575K | RESOLVE | CLASS - 1 | CU,05A10;02X10;11B07;29D06;39O02;40B07;70B07;52BB12/(05-A-10)CEASE USEITEM,DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WIT... | $2,500 | $0 | Apr 5, 2018 |
| Jun 24, 2016 | 38243875X | RESOLVE | CLASS - 2 | 05E01,10H11,77K10,39O02,70Z02,40P16. CAR DOOR RUBBING ADJUST, CAR DOOR GIBS WORN REPLACE, UNDERSIDE PLATFORM RUSTED R... | $500 | $0 | Aug 11, 2016 |
| May 25, 2016 | 38243068J | RESOLVE | CLASS - 1 | 05J01,05M07,59J01,40Q06,40Q06,59M07,59U15,68M07,98M05. CEASE USE-05JM ADJUST CAR DOORS TO ADEQUATE AND SUFFICIENT SPA... | $1,000 | $0 | Oct 27, 2016 |
| Oct 8, 2014 | 38233171Z | ACTIVE | CLASS - 2 | 02X10,16M07,14M07,15M07,37M07,42G07,39O02,52M12,54M12,70B10,80B07,30M07 70B-RELOCATE SUMP PUMP TUBING; 80B-PROVIDE CW... | $500 | -$250 | Dec 4, 2014 |
| Jun 9, 2014 | 38231661M | RESOLVE | CLASS - 2 | 97X10.97X10-RETURN ELEVATOR TO SERVICE | $500 | $0 | Jul 24, 2014 |
| Feb 20, 2013 | 38225610L | RESOLVE | CLASS - 2 | 40Z10,39O02,54L12,55L12,37L10,42M07,15L11,16M07. 40- SUMP PUMP PIPE ISBROKEN. 39- CAR TOP IS DIRTY. 54,55- DRUM MACHI... | $250 | $0 | Apr 11, 2013 |
| Mar 20, 2009 | 38201931X | RESOLVE | CLASS - 2 | 32H10,29Q03,39O02,39M07,14B10,24M07,11X10,100X10,41T07,61T07,52O02,68M07,56O02,60Q03,16T07,16L10,37T07,45B14,30Q03,70... | $250 | $0 | May 15, 2009 |
| Apr 24, 2003 | 38137365R | RESOLVE | Non-Hazardous | 80#11-39G10-62O2-62Z9-54H12-52Y14-37Y2. 80-RESTORE TO SERVICE SO FULL INSP CAN BE MADE BY THIS DEPT. | $0 | $0 | Jan 29, 2004 |
| Feb 26, 2003 | 38135366J | RESOLVE | Non-Hazardous | 79X11. DEVICE NOT OPERATING AT TIME OF INSPECTION RETURN DEVICE GACK TO SERVICE SO THAT A FULL INSPECTION CAN BE COND... | $180 | $0 | Apr 30, 2003 |
| Oct 5, 2001 | 38118921P | RESOLVE | Non-Hazardous | 46H13/ 05B01/ 31Q07/ 57O02/ 74O02/ 40P07/ 53M07 | $350 | $0 | Jan 10, 2002 |