3860-3866 Broadway, Manhattan
Manhattan • Block 02120 • Lot 0001 • Zip: 10032
Condition
What the city currently has open against this building, counted from its own records.
Address
Land use and zoning
Building
Latest assessment
Neighborhood
The area this lot falls inside, and the commute Hoodkit measures from it.
Getting around
Estimated 3 days ago- Times Square 28 min 5 walking, 23 riding
- Penn Station 32 min 5 walking, 27 riding
- Grand Central 36 min 5 walking, 31 riding
- Union Square 42 min 5 walking, 37 riding
- Fulton Street 43 min 5 walking, 38 riding
- Downtown Brooklyn 48 min 5 walking, 43 riding
Around this address
Transit and places within 0.5 miles of the lot.
Getting out
Subway
Railroad
Bus
Citi Bike
Places nearby
WaHi Diner
No description yet
Mike’s Bagels
No description yet
La Dinastia
No description yet
Native Noodles
Native Noodles offers a unique twist on traditional Asian cuisine, with a focus on fresh, locally sourced ingredients...
Carrot Top Pastries
No description yet
Döden
No description yet
Hilltop Park Alehouse
No description yet
Salento
No description yet
Activity
Sales, filings, permits and violations from every dataset, in one order.
2026
-
HPD violation Jul 30, 2026
Class A
§27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A C...
-
HPD violation Jul 30, 2026
Class A
§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
-
HPD violation Jul 28, 2026
Class C
§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICAT...
-
HPD violation Jul 28, 2026
Class B
§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 3rd ...
-
HPD violation Jul 28, 2026
Class C
§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF A KEY OPERATED LOCK INSTALLED AT THE DOOR TO THE RO...
-
HPD violation Jul 28, 2026
Class B
§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 64...
-
CLASS - 2
CLASS2 ITEMS: PHONE INOPERATIVE ASME A17.1-2013 SECTION 2.27.1.1 EMERGENCY COMMUNICATIONS REQUIRED, PIT DIRTY CLEAN I...
2025
-
CLASS - 2
1) PROVIDE CURRENT ELEVATOR COMPANY IDENTITY. 2) IN-CAR PHONE INOPERATIVE. 3) SECURE ELEVATOR OVERHEAD SHAFT DOOR WIT...
2023
-
DOB violation Oct 4, 2023
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
CLASS - 3
FAILURE TO MAINTAIN, OBSERVED WINDOW A/C UNITS ON FLOORS 2,3,4 AND 5, AT EXPOSURE#4 ARE MISSING SUPPORT BRACKETS, REP...
-
CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDINGS DEPT RECORDS. ENTIRE 1ST FLOOR OF BUI...
-
CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. 2ND MEANS OF EGRESS IN UNIT #2 IS 100% COMPROMISED DUE TO THE STORAG...
2021
-
CLASS - 1
FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/V39031320Y ISSUED6/20/20 &TO FILE C/C PURSUANT TO28-201...
-
DOB violation Aug 18, 2021
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
-
DOB violation Jan 20, 2021
AEUHAZ1-FAIL TO CERTIFY CLASS 1 NONE
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
2019
-
DOB violation Dec 17, 2019
E-ELEVATOR ELEVATORREQUIRED
2018
-
Alteration Type II
REMOVE PARTITIONS INSTALLED TO CREATE ADDITIONAL BEDROOM IN EXISTING APARTMENT 22. APPLICATION IS FILED TO OBTAIN DIS...
-
DOB violation Jan 26, 2018
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
2017
-
Alteration Type III
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL CO...
-
Alteration Type II
ACTIVATE GAS PORTION OF EXISTING GAS/OIL BURNER ON NYC BOILER # MD10158-01 AND INSTALL NEW GAS SERVICE, METER AND GAS...
2016
-
DOB violation Nov 14, 2016
ACC1-(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION ELEVATORREQUIRED
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
-
Alteration Type II
REPLACE BOILER AND OIL BURNER (NYC BOILER NO. MD 10158-01) WITH BOILER AND GAS/OIL BURNER (FUTURE GAS) AND CHANGE GRA...
2015
2014
-
Alteration Type III
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FILED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY...
2012
-
Alteration Type II
INTERIOR RENOVATION OF EXISTING RESTAURANT. NEW PARTITIONS, COOKING EQUIPEMNT, GAS RISER, PLUMBING FIXTURES AND SUSPE...
The most recent 6 events from each dataset, so no one source takes the axis. Each tab holds the full record.
Property Contacts
Contact information aggregated from multiple government sources
Registration Contracts
Contact information from multiple dwelling registrations
Building Permits
Owner information from Department of Buildings filings
Recent Building Permits
Owner information from recent DOB NOW filings
Deed Records
Parties from ACRIS deed and mortgage records
Property Records
Owner information from assessment and PLUTO records