Issued Violation Status Severity Description Penalty Balance due Hearing
Aug 16, 2005 38154435H RESOLVE Non-Hazardous 20I11/31H11/39P16/5B1/20-I-11 REPLACE DAMAGED VISION GLASS IN LOBBY 3RD FLOOR SHIFT DOORS 31-H-11 REPLACE WORN GUIDE ... $0 $0 Jan 18, 2007
Jul 22, 2005 34459007N RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR ... $700 $0 Sep 15, 2005
Jul 12, 2005 34484051P RESOLVE Hazardous FAILURE TO MAINTAIN BUILDING. DEFECTS NOTED: THE FLOORS IN THE CORRIDORS, AND KITCHEN OFF LEVEL APPROX. 4". (2) OPENI... $800 $0 Sep 1, 2005
Jun 15, 2005 34483863X RESOLVE Hazardous FAILURE TO MAINTAIN BULDING DEFECT NOTED THE FLOORS IN APARTMENT 65 AND THE CEILING IN APT 55 DROPPED OFF LEVEL APPRO... $800 $0 Aug 4, 2005
Jun 3, 2005 38152839P RESOLVE Non-Hazardous 38O02/51O02/52O02/28M07/08A01/71Q03/66O02/33O02/59Q03/40T07/83M07 38 CLEAN CAR TOP 51 CLEAN HOIST ROPES 52 CLEAN GOVE... $0 $0 Aug 18, 2005
Apr 29, 2005 34458481X RESOLVE Non-Hazardous 20050811YDE PROVISIONS:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED BY LOCAL LAW 11 OF 1998 AN... $0 $0 Jul 14, 2006
Nov 12, 2004 34462159J RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT:PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED ... $10,000 $0 Jan 20, 2005
Nov 8, 2004 38150105R RESOLVE Non-Hazardous 05K10/10M07/14M11/20M11/11L10/85BB05/28Q11/08V01/84H11/28H10/38O02/66O02/71X11/39P11/36P16 05K10 REPAIR BADLY RUSTED ... $350 $0 Dec 23, 2004
Sep 24, 2003 34416476X RESOLVE Non-Hazardous FAILURE TO SUBMIT A FIFTH ROUND TECHNICAL REPORT. PERIODIC INSPECTION OF EXTERIOR WALLS AND APPURTENANCES AS REQUIRED... $10,000 $0 Dec 11, 2003
May 30, 2003 34380219N RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR BLDG WALL DISLODGED MASONARY OVER LIMITED ON SAFE WEST ELEV W SEPARATING WINDOW FRAME OP... $2,500 $0 Jul 17, 2003
Apr 21, 2003 38136727K RESOLVE Non-Hazardous 81U05/ 52Y11/ 81/U 0 PERFORM 5YR TEST & PROPERLY TAG 52/Y - OIL LEAKING FROM SIDE OF GEAR CASE $0 $0 Jun 5, 2003
Apr 11, 2002 34316340Z RESOLVE Non-Hazardous FAILURE TO MAINTAIN BUILDING. DEFECT AT APT 47 THE FLOOR IN HALLWAY APPROX 9 SQ FT IS SINKING TOWARDS THE BATHROOM CO... $2,500 $0 May 30, 2002
Mar 19, 2001 34206474R RESOLVE Hazardous FAILURE TO MAINTAINEXTERIOR BLDG WALL.NOTED AT N FACADE,2ND FLOOR BALCONY,2 BALUSTERS WITH HALF OF EACH GONE AND OTHE... $2,500 $0 May 3, 2001
Jun 13, 2000 34206331J RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL.NOTED AT NORTH ELEVATION-EAST SIDE 2ND FLOOR BRICKS MISSING;VERTICAL CRACK... $2,500 $0 Aug 3, 2000
Mar 10, 1998 34156292N RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND FOUR REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5),INDICA... $2,500 $0 Jun 17, 1999
Feb 3, 1998 34156239Y RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND 4 REPORT ACCEPTABLE TO THIS DEPT PURSUANT TO RULE RCNY 32-03B(5), INDICATING CORRECT... $1,000 $0 Jul 21, 1998
Nov 18, 1997 34156128L RESOLVE Hazardous FAILURE TO FILE AN AMENDED ROUND FOUR REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y 32-03B (5) INDICA... $2,500 $0 Jan 29, 1998
Aug 5, 1996 34138297N RESOLVE Non-Hazardous FAILURE TO MAINTAIN EXTERIOR BUILDING WALL DEFECTS ARE VERTICAL CRACKS OF EXTERIO BRICK WALL EAST SIDE OF REAR COURT ... $350 $0 Feb 13, 1997
Mar 12, 1996 38055196X RESOLVE Non-Hazardous 03M,14L,75I,17R,17Q,25H,30I,30M,33I,46L,49L,50Y,50Y,50Y,61K,63H,62I,42I,73O. 03M HANDRAIL 15I BSMT DOOR 30I I BEAM AB... $500 $0 Jun 13, 1996
Jun 21, 1995 38049774H RESOLVE Non-Hazardous 14L,15I,17R,17Q,25Q,25H,15M,30I,33I,50Y,49L,63H,28L. 15I-BASEMNT DOOR#'S.30I-I-BEAM ABOVE BASEMNT. 33I-SKYLIGHT. $500 $0 Nov 30, 1995
Sep 20, 1994 38044379P RESOLVE Non-Hazardous 22D,33W,33M,50Y,35Y,61K,40#,58D,47L 33-LIGHTS 40-OVERHAUL -CALIBRATE-SEAL,CEASE USE UNTIL 58&47 IS COMPLIED WITH CALL... $500 $0 Nov 17, 1994
Dec 27, 1993 38039585J RESOLVE Non-Hazardous 17R,22D,28L,73X. 17R FOR WIRE GLASS. 28 STEADYING PLATES. 73 RESTORE TO SERVICE SO THAT A FULL INSPECTION CAN BE MADE... $100 $0 Mar 25, 1994
Apr 9, 1993 38032880K RESOLVE Non-Hazardous 03M,03I,08V,15M,17M,22R,29M,33L,47I,57O,50Y,50Y, 03M-CAPACITY PLATE AND HANDRAILS 03I-FLOOR FILES 15M-FLOOR #'S 17M-B... $0 $0 Jun 17, 1993
Mar 3, 1992 38021284K RESOLVE Non-Hazardous 28L,14M,35P, $185 $0 May 21, 1992
Apr 24, 1991 38010230L RESOLVE Non-Hazardous 28L,14M,73O $0 $0 Apr 2, 1992
Aug 1, 1988 34011191R RESOLVE Hazardous FAILURE TO MAINTAIN EXTERIOR. REMEDY: MAKE ALL REPAIRS TO THE SATISFACTION OF THIS DEPT. $1,000 $0 Nov 18, 1988