ECB violations
118-128 Fort Washington Avenue, Manhattan • Block 02137 • Lot 0157
84 records
Environmental Control Board violations, which carry a hearing and a penalty.
| Issued | Violation | Status | Severity | Description | Penalty | Balance due | Hearing |
|---|---|---|---|---|---|---|---|
| Dec 18, 2025 | 39170878N | ACTIVE | CLASS - 1 | CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR. CLASS 2 ITEMS: INAUDIBLE IN CAR STOP SWITCH. ADJUST IN CAR STOP SWI... | $1,250 | $1,250 | Sep 2, 2026 |
| Jul 7, 2025 | 39152930M | RESOLVE | CLASS - 1 | CLASS 1: UPON INSPECTION FOUND DEVICE TO BE OUT OF SERVICE. RESTORE SERVICE IMMEDIATLY AS PER 1 RCNY 11-02. WHEN SERV... | $3,125 | $3,125 | Apr 8, 2027 |
| Jun 16, 2025 | 39151200X | RESOLVE | CLASS - 2 | CLASS 2 ITEMS: CATEGORY 1 TEST TAG EXPIRED. CLEAN ELEVATOR MACHINE ROOM. | $0 | $0 | Aug 21, 2025 |
| Mar 14, 2025 | 39141612N | RESOLVE | CLASS - 1 | CLASS 2: PROGRAM PHONE TO ELEVATOR COMPANY. PROVIDE BRAILLE TAGS AS REQUIRED.CAPACITY PLATE MISSING FROM CAR STATION.... | $0 | $0 | Jun 18, 2026 |
| Dec 3, 2024 | 39131864K | RESOLVE | CLASS - 1 | CLASS 1: IN CAR STOP SWITCH INOPERATIVE REPAIR (CU). GOVENOR ROPE HAS KINK REPLACE ROPE & RETEST (CU). HOIST ROPES WO... | $1,250 | $0 | Mar 6, 2025 |
| Feb 15, 2022 | 39056177L | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371... | $625 | $0 | Nov 10, 2022 |
| Feb 15, 2022 | 39056176J | RESOLVE | CLASS - 2 | RESIDENCE CONVERTED FROM 1 FAMILY TO 2 FAMILY DWELLING UNIT. NOTED AT APT 4D ON 4TH FL 1ST BDRM OCCUPIED AS A SRO WIT... | $2,500 | $0 | Nov 10, 2022 |
| Apr 28, 2021 | 39040264N | RESOLVE | CLASS - 2 | FOUND EXPOSED WIRING, BELT GUARD MISSING ON OIL PUMP SET AND AIR COMPRESSOR, BODY DRAINS MISSING ON RELIEF VALVES, MA... | $312 | $0 | Aug 26, 2021 |
| Feb 24, 2021 | 39036762Y | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED NO DLM INSTALL IN CONTROLLER, AS MANDATED BY3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC ,REMEDY... | $1,250 | $0 | Aug 12, 2021 |
| Feb 24, 2021 | 39036763X | RESOLVE | CLASS - 1 | CLASS 1 VIOLATION ISSUED NO DLM IN CONTROLLER AS MANDATED BY 3.10.12OF APPENDIX K3 OF THE 2014 NYCBC REMEDY; FILE APP... | $1,250 | $0 | Aug 12, 2021 |
| Oct 2, 2020 | 39029706Y | RESOLVE | CLASS - 1 | 1. REPAIR IN CAR PHONE. 2. PROVIDE DOOR LOCK MONITORING. 3. PROVIDE CORRECT AMP FUSES ON CONTROLLER. | $3,125 | $0 | Dec 31, 2020 |
| Oct 2, 2020 | 39029707X | RESOLVE | CLASS - 1 | 1. IN CAR COMMUNICATION INOPERATIVE-REPAIR 2. PROVIDE DOOR LOCK MONITORING. 3. FUSES ON CONTROLLER ILLEGIBLE REPAIR | $3,125 | $0 | Dec 31, 2020 |
| Jun 2, 2020 | 39023283Y | RESOLVE | CLASS - 1 | 1. REPAIR PHONE. 2. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE... | $1,250 | $0 | Jul 23, 2020 |
| Jun 2, 2020 | 39023281K | RESOLVE | CLASS - 1 | 1. REPAIR PHONE. 2. MIRROR MISSING. 3.NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF ... | $1,250 | $0 | Jul 23, 2020 |
| Mar 4, 2020 | 39018871Y | RESOLVE | CLASS - 1 | NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS... | $1,250 | $0 | Feb 25, 2021 |
| Feb 6, 2020 | 39017006P | RESOLVE | CLASS - 2 | FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES. NOTED, AT TIME OF INSPECTION I OBSERVED A WINDOW A/C UNIT EREC... | $1,250 | $0 | Jan 14, 2021 |
| Apr 8, 2019 | 38269176M | RESOLVE | CLASS - 1 | CEASE USE (05A10), 69B07, 41I10, 68B07, 56Y13, 70O02, 39X10, 59BB07, 26D06, 42B09, 44M08, 39X10, 67X10.CEASE USE ITEM... | $1,250 | $0 | Aug 22, 2019 |
| Mar 20, 2018 | 35286015R | RESOLVE | CLASS - 2 | FAILURE TO PROVIDE SIDEWALK SHED PARAPET SIGN. NOTED: AT TIME OF INSPECTION SIDEWALK SHED MISSING PARAPET SIGN ACCORD... | $0 | $0 | May 10, 2018 |
| Aug 22, 2017 | 38257503M | RESOLVE | CLASS - 1 | 5M7,2M7,70O2,39I10. 5M7-CEASE USE ITEM DOOR ZONE RESTRICTOR.THIS IS ASAFETY DEVICE OT ENSURE ELEVATOR PASSENGERS SAFE... | $1,000 | $0 | Jun 14, 2018 |
| Jul 31, 2017 | 38256939Z | RESOLVE | CLASS - 1 | 97X17 THE ONLY ELEVATOR IN BUILDING (OR SECTION OF BUILDING) OUT OF SERVICE.UPON INSPECTION THE DEVIC EIS FOUND TO BE... | $1,000 | $0 | Jan 11, 2018 |
| Nov 7, 2016 | 37001757R | RESOLVE | CLASS - 2 | FAILURE TO FILE ACCEPTABLE AMENDED REPROT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 1... | $800 | $0 | Apr 20, 2017 |
| Mar 31, 2016 | 35134043L | RESOLVE | CLASS - 1 | FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SIDEWAK SHED,FENCTETC TO PROTECT PUBLIC FROM UNSAFE FACADES AT EX... | $2,400 | $0 | Sep 29, 2016 |
| Mar 24, 2016 | 35174227M | RESOLVE | CLASS - 1 | FAILURE TO TAKE PROVIDE SAFETY MEASURE/SIDEWALK SHED,NETTING,ETC,WHEREREQUIRE TO PROTECT & SECURE PUBLIC SAFETY FROM ... | $2,400 | $0 | Nov 3, 2016 |
| Dec 18, 2015 | 38240202H | RESOLVE | CLASS - 2 | 40Z10,45V07,15P16. 40Z10- ROOF IN MOTOR ROOM NEED REPAIR HIC #1408326 | $0 | $0 | Feb 4, 2016 |
| Dec 18, 2015 | 38240203J | RESOLVE | CLASS - 2 | 45U07. CLASS 2 VIOLATION ISSUED FOR ABOVE ITEM HIC #1408326 | $0 | $0 | Feb 4, 2016 |
| Oct 15, 2015 | 38238598K | RESOLVE | CLASS - 1 | CU-100R05 DEVICE SHUT DOWN ILLEGAL OPERATION W/O TESTING THE DEVICE NO SHOW ON TEST DATE 10-15-2015 AND DEVICE IN SER... | $250 | $0 | Dec 3, 2015 |
| Jul 29, 2015 | 35132759H | RESOLVE | CLASS - 1 | FAILURE TO TAKE REQUIRED MEASURES TO SECURE PUBLIC SAFETY-UNSAFE FACADE.NOTED:@ TIME OF INSP NO SAFETY MEAUSRES IN PL... | $6,000 | $0 | Feb 18, 2016 |
| May 29, 2015 | 36027543K | RESOLVE | CLASS - 2 | FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DE... | $0 | $0 | Jan 21, 2016 |
| Feb 27, 2014 | 35024218R | RESOLVE | CLASS - 1 | FAILURE TO TAKE AND PROVIDE SAFETY MEASURES (SIDEWALK SHED,NETTING ETC)WHERE REQUIRED TO PROTECT AND SECURE PUBLIC SA... | $24,000 | $0 | Apr 17, 2014 |
| Apr 18, 2013 | 35001805J | RESOLVE | CLASS - 1 | *FAILURE TO TAKE AND PROVIDE SAFETY MEASURES WHERE REQUIRED TO PROTECTAND SECURE PUBLIC SAFETY FROM DOCUMENTED UNSAFE... | $2,400 | $0 | Oct 3, 2013 |
| Sep 13, 2012 | 38223530M | RESOLVE | CLASS - 2 | 40P16,15T07,12Q03,08V01,37Y02,39Y02,(67M02),53O02,34O02,76J01,77B11. 40P- NO AVAILABLE ACCESS. 15T- NO STAMP/SIGNATUR... | $0 | $0 | Nov 1, 2012 |
| Nov 9, 2011 | 38218767Y | RESOLVE | CLASS - 2 | 39I11/ 70O02/ 12X10/ 39O02/ | $500 | $0 | Feb 16, 2012 |
| Nov 9, 2011 | 38218766M | RESOLVE | CLASS - 2 | 08V01/ 42N11/ 60X10/ 26D06/ 70O02/ 42- BY PASSED FUSE ON CONTROLLER - REPLACE | $500 | $0 | Feb 16, 2012 |
| Jun 11, 2010 | 36013517J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESC... | $8,000 | $0 | Mar 17, 2011 |
| Jan 9, 2009 | 36007395J | RESOLVE | CLASS - 2 | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRI... | $4,000 | $0 | Oct 8, 2009 |
| May 9, 2008 | 34684455H | RESOLVE | Non-Hazardous | FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS ... | $700 | $0 | Dec 11, 2008 |
| Dec 9, 2004 | 34455564H | RESOLVE | Non-Hazardous | BATHROOMS AND TOILET ROOMS SHALL BE VENTED. ERECTED A NEW BATHROOM WITH NEW WALLS AND SUSPENDED CEILING WITH NO VENTI... | $400 | $0 | Sep 15, 2005 |
| Dec 9, 2004 | 34455563X | RESOLVE | Hazardous | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY 116092 OF DEC.10,1998. NOTED: LEGAL OCCUPANCY IN B... | $800 | $0 | Sep 15, 2005 |
| Dec 7, 2004 | 34455562Y | RESOLVE | Hazardous | WORK WITHOUT A PERMIT. WORK NOTED: ERECTED NEW PARTITIONS TO CREATE NEW BEAUTY PARLOR WITH BATHROOM; NEW CEILING WITH... | $0 | $0 | Sep 15, 2005 |
| Sep 30, 2003 | 34416400J | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS... | $1,750 | $0 | Apr 1, 2004 |
| Jul 14, 2003 | 34388702J | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPT INDICATION CORRECTION OF UNSAFE CONDITIONS DESCR... | $700 | $0 | Sep 25, 2003 |
| May 23, 2003 | 34388667N | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT, INDICATING CORRECTION OF UNSAFE CONDITION... | $1,750 | $0 | Dec 18, 2003 |
| Mar 28, 2003 | 34388398Y | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y 32-03B(5),INDICAT... | $1,750 | $0 | Jul 3, 2003 |
| Feb 27, 2003 | 34336706M | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR OF BUILDING IMPROPERLY MOUNTED WINDOW A.C UNITS ON THIS 6 FLOOR ON THE SOUTH ELEV ALSO O... | $0 | $0 | Oct 23, 2003 |
| Feb 27, 2003 | 34336707Y | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR OF BUILDING SEVERELY RUSTED & BOUED WINDOW ANGLE LRIONS ON THE EAST ELEV ON TEH 6,7,8 7 ... | $800 | $0 | Oct 31, 2003 |
| Jan 21, 2003 | 34379935X | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDIC... | $1,000 | $0 | May 1, 2003 |
| Nov 15, 2002 | 34335727R | RESOLVE | Hazardous | FAILURE TO FILE AN AMENDED ROUND FIVE REPORT ACCEPTABLE TO THIS DEPARTMENT PURSUANT TO RULE R.C.N.Y. 32-03B(5), INDIC... | $700 | $0 | Nov 20, 2003 |
| Sep 16, 2002 | 34336391R | RESOLVE | Hazardous | FAILURE TO MAINTAIN EXTERIOR BUILDING WALL NOTED ON THE WEST, SOUTH AND EAST FACADES SEVERAL IMPROPERLY MTD WINDOW AC... | $800 | $0 | Oct 31, 2002 |
| Apr 15, 2002 | 38122781Y | RESOLVE | Non-Hazardous | 25B01/18B01/03B11/50Y14/13B01/25 ADJTO OPEN FULLY (NORMALLY AND REOPEN )18-ADJ 7 FL LOCK 03-REPAIR CAR FAN 50-STOP OI... | $0 | $0 | May 30, 2002 |
| Apr 15, 2002 | 38122782X | RESOLVE | Non-Hazardous | 14B07/03D09/18B01/ 14-PUT CERT OR LOCATION SIGN IN FRAME 03- REMOVE ALL FLAMEABLES FROM CAR TOP 18-ADJ DOOR LOCK ON 2 FL | $0 | $0 | May 30, 2002 |